Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

被引:24
作者
Carrabba, Michele [1 ]
Vichi, Alessandro [1 ]
Louca, Chris [2 ]
Ferrari, Marco [1 ]
机构
[1] Univ Siena, Dept Med Biotechnol, Siena, Italy
[2] Univ Portsmouth Dent Acad, Portsmouth, Hants, England
关键词
Phosphate acid monomers; Ceramics; Surface treatment; Chipping repair; Ceramic repair system; FIXED DENTAL PROSTHESES; SHEAR BOND STRENGTH; FLOWABLE COMPOSITE RESIN; MICROTENSILE SPECIMENS; COMPLICATION RATES; SURFACE TREATMENTS; OBSERVATION PERIOD; PORCELAIN REPAIR; RESTORATIONS; SURVIVAL;
D O I
10.4047/jap.2017.9.4.257
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 39 条
[1]  
Addison O, 2008, J ADHES DENT, V10, P285
[2]   Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses [J].
Anusavice, Kenneth J. .
DENTAL MATERIALS, 2012, 28 (01) :102-111
[3]  
Blum I R, 2011, SADJ, V66, P160
[4]  
Blum Igor R, 2011, Dent Update, V38, P150
[5]  
Blum IR, 2011, DENT UPDATE, V38, P154
[6]   REPAIR OF FRACTURED PORCELAIN UNITS - ALTERNATIVE APPROACHES [J].
BURKE, FJT ;
GREY, NJA .
BRITISH DENTAL JOURNAL, 1994, 176 (07) :251-256
[7]   SHEAR VS TENSILE BOND STRENGTH OF RESIN COMPOSITE BONDED TO CERAMIC [J].
DELLABONA, A ;
VANNOORT, R .
JOURNAL OF DENTAL RESEARCH, 1995, 74 (09) :1591-1596
[8]   Shear bond strength of a new self-adhering flowable composite resin for lithium disilicate-reinforced CAD/CAM ceramic material [J].
Erdemir, Ugur ;
Sancakli, Hande Sar ;
Sancakli, Erkan ;
Eren, Meltem Mert ;
Ozel, Sevda ;
Yucel, Taner ;
Yildiz, Esra .
JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (06) :434-443
[9]   Microtensile bond strength tests: scanning electron microscopy evaluation of sample integrity before testing [J].
Ferrari, M ;
Goracci, C ;
Sadek, F ;
Cardoso, PEC .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (05) :385-391
[10]  
Goia TS, 2006, INT J PROSTHODONT, V19, P400