Coherent femtosecond pulse shaping for the optimization of a non-linear micro-endoscope

被引:22
作者
Lelek, M.
Suran, E.
Louradour, F.
Barthelemy, A.
Viellerobe, B.
Lacombe, F.
机构
[1] Univ Limoges, CNRS, UMR, XLIM Inst Rech, F-87060 Limoges, France
[2] Mauna Kea Technol, F-75010 Paris, France
关键词
D O I
10.1364/OE.15.010154
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A flexible multicore fiber bundle is fed by temporally and spectrally shaped femtosecond pulses allowing for the pre-compensation of both chromatic dispersion and non-linear effects encountered in the bundle. We demonstrate that the pulse duration at the fiber bundle output can be significantly reduced in comparison with linear pre-compensation only. The scheme for femtosecond pulse fiber delivery is applied to the optimization of two-photon fluorescence (TPF) imaging. Experiments and calculations show a five-fold improvement of the TPF signal produced at the end of the fiber bundle in comparison with linear pre-compensation. This is applied to the recording, in real time (12 image/s), of TPF laser-scanning images of human colon cells stained with a fluorescent marker. Further optimizations are discussed. (c) 2007 Optical Society of America.
引用
收藏
页码:10154 / 10162
页数:9
相关论文
共 27 条
[1]  
Agrawal G. P, 2012, Nonlinear Fiber Optics, V5th
[2]  
[Anonymous], P IEEE INT S BIOM IM
[3]   Nuclear energy in the twenty-first century: Examination of a contentious subject [J].
Beck, PW .
ANNUAL REVIEW OF ENERGY AND THE ENVIRONMENT, 1999, 24 :113-137
[4]   Two-photon fluorescence endoscopy with a micro-optic scanning head [J].
Bird, D ;
Gu, M .
OPTICS LETTERS, 2003, 28 (17) :1552-1554
[5]   Fiber delivery of femtosecond pulses from a Ti:sapphire laser [J].
Clark, SW ;
Ilday, FÖ ;
Wise, FW .
OPTICS LETTERS, 2001, 26 (17) :1320-1322
[6]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[7]   Dispersion measurements with white-light interferometry [J].
Diddams, S ;
Diels, JC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1996, 13 (06) :1120-1129
[8]   Fiber-optic fluorescence imaging [J].
Flusberg, BA ;
Cocker, ED ;
Piyawattanametha, W ;
Jung, JC ;
Cheung, ELM ;
Schnitzer, MJ .
NATURE METHODS, 2005, 2 (12) :941-950
[9]   In vivo brain imaging using a portable 3.9 gram two-photon fluorescence microendoscope [J].
Flusberg, BA ;
Lung, JC ;
Cocker, ED ;
Anderson, EP ;
Schnitzer, MJ .
OPTICS LETTERS, 2005, 30 (17) :2272-2274
[10]   Nonlinear optical microscopy based on double-clad photonic crystal fibers [J].
Fu, L ;
Gan, XS ;
Gu, M .
OPTICS EXPRESS, 2005, 13 (14) :5528-5534