Relating mechanical properties of vertebral trabecular bones to osteoporosis

被引:10
作者
Cesar, R. [1 ]
Bravo-Castillero, J. [2 ,3 ]
Ramos, R. R. [4 ]
Pereira, C. A. M. [5 ]
Zanin, H. [6 ]
Rollo, J. M. D. A. [7 ]
机构
[1] Univ Sao Paulo, Dept Mech Engn, Sao Carlos Sch Engn, Sao Carlos, SP, Brazil
[2] Univ Nacl Autonoma Mexico, IIMAS, Mexico City, DF, Mexico
[3] Parque Cient Tecnol Yucatan, Unidad Acad Yucatan, IIMAS UNAM Merida, Merida, Yucatan, Mexico
[4] Univ La Habana, Fac Matemat & Comp, Havana, Cuba
[5] Univ Sao Paulo, Orthoped & Traumatol Inst, Clin Hosp, Sao Paulo, SP, Brazil
[6] Univ Estadual Campinas, Carbon Sci Tech Labs, Sch Elect & Comp Engn, Campinas, SP, Brazil
[7] Univ Sao Paulo, Dept Mat Engn, Sao Carlos Sch Engn, Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Trabecular bone; osteoporosis; microtomography; mechanical resistance; asymptotic homogenization; FRACTURE RISK-ASSESSMENT; FINITE-ELEMENT MODELS; ELASTIC PROPERTIES; CANCELLOUS BONE; ASYMPTOTIC HOMOGENIZATION; NUMERICAL-SIMULATION; COMPACT-BONE; STRENGTH; ANISOTROPY; MANAGEMENT;
D O I
10.1080/10255842.2019.1699542
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Osteoporosis is an osteometabolic disease, which promotes structural degradation of bone tissue and reduction of mineral density. We reported here a mechanical resistance assay from normal, osteopenic and osteoporotic trabecular vertebral bones of human cadavers. We performed a compressed test on ninety samples, evaluating Young's modulus and X-ray microtomography to measure bone volume fraction and trabecular thickness. This experimental data are employed for computing the orthotropic macroscopic behavior of vertebral trabecular bones using known analytical formulae that were obtained by Galka et al. (Arch Mech 51: 335-355, 1999) via an asymptotic homogenization model. A geometrical model with a periodic orthogonal plate-like structure is applied. The properties of the bone-trabecular mass are considered linear, homogeneous and orthotropic. Average values for all technical or engineering elastic properties are computed for three important regions of the trabecular bones corresponding to thirty individuals classified as normal, osteopenic or osteoporotic by calcaneus ultrassometry. This study could be useful for a better understanding of the elastic behavior of trabecular bones in human vertebral bodies, allowing an estimation of bone answer under stress in different directions and the risk of fracture associated with osteoporosis.
引用
收藏
页码:54 / 68
页数:15
相关论文
共 110 条
[11]   The Clinical Utility of Vertebral Fracture Assessment in Predicting Fractures [J].
Borges, Joao Lindolfo C. ;
Miranda, Isabella Santiago de M. ;
Michael Lewiecki, E. .
JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) :304-308
[12]   Changes in bone matrix properties with aging [J].
Burr, David B. .
BONE, 2019, 120 :85-93
[13]   bgb Evaluation of trabecular microarchitecture of normal osteoporotic and osteopenic human vertebrae [J].
Cesar, R. ;
Boffa, R. S. ;
Fachine, L. T. ;
Leivas, T. P. ;
Silva, A. M. H. ;
Pereira, C. A. M. ;
Reiff, R. B. M. ;
Rollo, J. M. D. A. .
3RD INTERNATIONAL CONFERENCE ON TISSUE ENGINEERING (ICTE2013), 2013, 59 :6-15
[14]  
Cesar Reinaldo, 2017, Res. Biomed. Eng., V33, P91
[15]   Fracture Risk Assessment in Clinical Practice: Why Do It? What to Do It With? [J].
Chandran, Manju .
JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) :274-279
[16]   New laboratory tools in the assessment of bone quality [J].
Chappard, D. ;
Basle, M. F. ;
Legrand, E. ;
Audran, M. .
OSTEOPOROSIS INTERNATIONAL, 2011, 22 (08) :2225-2240
[17]  
Chappard D., 2008, Morphologie, V92, P162, DOI 10.1016/j.morpho.2008.10.003
[18]   Homogenization Techniques and Micromechanics. A Survey and Perspectives [J].
Charalambakis, Nicolas .
APPLIED MECHANICS REVIEWS, 2010, 63 (03) :1-10
[19]   Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: A validation study [J].
Chen, Yuan ;
Dall'Ara, Enrico ;
Sales, Erika ;
Manda, Krishnagoud ;
Wallace, Robert ;
Pankaj, Pankaj ;
Viceconti, Marco .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 :644-651
[20]  
Cherraf-Schweyer C., 2007, Computer Methods in Biomechanics and Biomedical Engineering, V10, P195, DOI 10.1080/10255840701284002