Validation of ground-based visible measurements of total ozone by comparison with Dobson and Brewer spectrophotometers

被引:60
作者
Van Roozendael, M
Peeters, P
Roscoe, HK
De Backer, H
Jones, AE
Bartlett, L
Vaughan, G
Goutail, F
Pommereau, JP
Kyro, E
Wahlstrom, C
Braathen, G
Simon, PC
机构
[1] Inst Aeron Spatiale Belgique, B-1180 Brussels, Belgium
[2] Koninklijk Meteorol Inst, B-1180 Brussels, Belgium
[3] British Antarctic Survey, Cambridge CB3 0ET, England
[4] Univ Wales, Dept Phys, Aberystwyth, Dyfed, Wales
[5] CNRS, Serv Aeron, F-91371 Verrieres Le Buisson, France
[6] Finnish Meteorol Inst, Sodankyla Observ, SF-99600 Sodankyla, Finland
[7] NILU, N-2007 Kjeller, Norway
关键词
stratosphere; ozone; validation;
D O I
10.1023/A:1005815902581
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Comparisons of total column ozone measurements from Dobson, Brewer and SAOZ instruments are presented for the period 1990 to 1995 at seven stations covering the mid-and the high northern latitudes, as well as the Antarctic region. The main purpose of these comparisons is to assess, by reference to the well established Dobson network, the accuracy of the zenith-sky visible spectroscopy for the measurement of total ozone. The strengths and present limitations of this latter technique are investigated. As a general result, the different instruments are found to agree within a few percent at all stations, the best agreement being obtained at mid-latitudes. On average, for the mid-latitudes, SAOZ O-3 measurements are approximately 2% higher than Dobson ones, with a scatter of about 5%. At higher latitudes, both scatter and systematic deviation tend to increase. In all cases, the relative differences between SAOZ and Dobson or Brewer column ozone are characterised by a significant seasonal signal, the amplitude of which increases from about 2.5% at mid-latitude to a maximum of 7.5% at Faraday, Antarctica. Although it introduces a significant contribution to the seasonality at high latitude, the temperature sensitivity of the O-3 absorption coefficients of the Dobson and Brewer instruments is shown to be too small to account for the observed SAOZ/Dobson differences. Except for Faraday, these differences can however be largely reduced if SAOZ AMFs are calculated with realistic climatological profiles of ozone, pressure and temperature. Other sources of uncertainties that might affect the comparison are investigated. Evidence is found that the differences in the air masses sampled by the SAOZ and the other instruments contribute significantly to the scatter, and the impact of the tropospheric clouds on SAOZ measurements is displayed.
引用
收藏
页码:55 / 83
页数:29
相关论文
共 50 条
  • [31] Validation of Carbon Monoxide Total Column Retrievals from SCIAMACHY Observations with NDACC/TCCON Ground-Based Measurements
    Hochstaffl, Philipp
    Schreier, Franz
    Lichtenberg, Guenter
    Garcia, Sebastian Gimeno
    REMOTE SENSING, 2018, 10 (02):
  • [32] Evaluation of Total Ozone Column from Multiple Satellite Measurements in the Antarctic Using the Brewer Spectrophotometer
    Kim, Songkang
    Park, Sang-Jong
    Lee, Hana
    Ahn, Dha Hyun
    Jung, Yeonjin
    Choi, Taejin
    Lee, Bang Yong
    Kim, Seong-Joong
    Koo, Ja-Ho
    REMOTE SENSING, 2021, 13 (08)
  • [33] Comparison of INSAT-3D retrieved total column ozone with ground-based and AIRS observations over India
    Kumar, Ravi Ranjan
    Vankayalapati, Koteswara Rao
    Soni, V. K.
    Dasari, Hari Prasad
    Jain, M. K.
    Tiwari, Arpit
    Giri, R. K.
    Desamsetti, Srinivas
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 793
  • [34] Ground-based measurements of total column of hydrogen chloride in the atmosphere near St. Petersburg
    Polyakov, A. V.
    Timofeev, Yu. M.
    Poberovskii, A. V.
    IZVESTIYA ATMOSPHERIC AND OCEANIC PHYSICS, 2013, 49 (04) : 411 - 419
  • [35] Ground-based FTIR remote sensing of ozone
    Briz, S
    deCastro, AJ
    Melendez, J
    Meneses, J
    Aranda, JM
    Lopez, F
    SPECTROSCOPIC ATMOSPHERIC MONITORING TECHNIQUES, 1997, 3106 : 159 - 170
  • [36] Multi-year comparison of stratospheric BrO vertical profiles retrieved from SCIAMACHY limb and ground-based UV-visible measurements
    Hendrick, F.
    Rozanov, A.
    Johnston, P. V.
    Bovensmann, H.
    De Maziere, M.
    Fayt, C.
    Hermans, C.
    Kreher, K.
    Lotz, W.
    Sinnhuber, B. -M.
    Theys, N.
    Thomas, A.
    Burrows, J. P.
    Van Roozendael, M.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2009, 2 (01) : 273 - 285
  • [37] VALIDATION OF SATELLITE MICROWAVE RETRIEVED SOIL MOISTURE WITH GLOBAL GROUND-BASED MEASUREMENTS
    Al-Yaari, A.
    Mialon, A.
    Dorigo, W.
    Colliander, A.
    Fan, L.
    Kerr, Y.
    Pellarin, T.
    Wigneron, J. -P.
    IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 3743 - 3746
  • [38] Validation of the OMI-TOMS and OMI-DOAS total ozone column data using ground-based observations over China
    Ma, Mingliang
    Shi, Runhe
    Gao, Wei
    REMOTE SENSING AND MODELING OF ECOSYSTEMS FOR SUSTAINABILITY XII, 2015, 9610
  • [39] Comparison of long-term total ozone observations from space- and ground-based methods at Zhongshan Station, Antarctica
    Zhang Lei
    Zheng XiangDong
    Bian LinGen
    SCIENCE CHINA-EARTH SCIENCES, 2017, 60 (11) : 2013 - 2024
  • [40] A comparison of Jason-2 plasmasphere electron content measurements with ground-based measurements
    Mazzella Jr, Andrew J.
    Yizengaw, Endawoke
    ANNALES GEOPHYSICAE, 2023, 41 (01) : 269 - 280