Simultaneous high-resolution T2-weighted imaging and quantitative T2 mapping at low magnetic field strengths using a multiple TE and multi-orientation acquisition approach

被引:13
作者
Deoni, Sean C. L. [1 ,2 ,3 ]
O'Muircheartaigh, Jonathan [4 ,5 ,6 ]
Ljungberg, Emil [7 ,8 ]
Huentelman, Mathew [9 ]
Williams, Steven C. R. [8 ]
机构
[1] Rhode Isl Hosp, Adv Baby Imaging Lab, Providence, RI USA
[2] Brown Univ, Warren Alpert Med Sch, Dept Diagnost Radiol, Providence, RI 02912 USA
[3] Brown Univ, Warren Alpert Med Sch, Dept Pediat, Providence, RI 02912 USA
[4] Kings Coll London, Ctr Developing Brain, Sch Biomed Engn & Imaging Sci, London, England
[5] Kings Coll London, Dept Perinatal Imaging & Hlth, London, England
[6] Kings Coll London, MRC Ctr Neurodev Disorders, London, England
[7] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[8] Kings Coll London, Dept Neuroi Magi Ng, London, England
[9] Translat Genom Res Inst, Neurogen Div, Phoenix, AZ USA
基金
英国工程与自然科学研究理事会; 美国国家卫生研究院; 英国医学研究理事会;
关键词
child brain development; low field MRI; magnetic resonance imaging; pediatric neuroimaging; NMR RELAXATION-TIMES; SIGNAL-TO-NOISE; BRAIN; MRI; SUPERRESOLUTION; RECONSTRUCTION;
D O I
10.1002/mrm.29273
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Low magnetic field systems provide an important opportunity to expand MRI to new and diverse clinical and research study populations. However, a fundamental limitation of low field strength systems is the reduced SNR compared to 1.5 or 3T, necessitating compromises in spatial resolution and imaging time. Most often, images are acquired with anisotropic voxels with low through-plane resolution, which provide acceptable image quality with reasonable scan times, but can impair visualization of subtle pathology. Methods Here, we describe a super-resolution approach to reconstruct high-resolution isotropic T-2-weighted images from a series of low-resolution anisotropic images acquired in orthogonal orientations. Furthermore, acquiring each image with an incremented TE allows calculations of quantitative T-2 images without time penalty. Results Our approach is demonstrated via phantom and in vivo human brain imaging, with simultaneous 1.5 x 1.5 x 1.5 mm(3) T-2-weighted and quantitative T-2 maps acquired using a clinically feasible approach that combines three acquisition that require approximately 4-min each to collect. Calculated T-2 values agree with reference multiple TE measures with intraclass correlation values of 0.96 and 0.85 in phantom and in vivo measures, respectively, in line with previously reported brain T-2 values at 150 mT, 1.5T, and 3T. Conclusion Our multi-orientation and multi-TE approach is a time-efficient method for high-resolution T-2-weighted images for anatomical visualization with simultaneous quantitative T-2 imaging for increased sensitivity to tissue microstructure and chemical composition.
引用
收藏
页码:1273 / 1281
页数:9
相关论文
共 45 条
  • [11] Investigating white matter development in infancy and early childhood using myelin water faction and relaxation time mapping
    Deoni, Sean C. L.
    Dean, Douglas C., III
    O'Muircheartaigh, Jonathan
    Dirks, Holly
    Jerskey, Beth A.
    [J]. NEUROIMAGE, 2012, 63 (03) : 1038 - 1053
  • [12] Fast and robust multiframe super resolution
    Farsiu, S
    Robinson, MD
    Elad, M
    Milanfar, P
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (10) : 1327 - 1344
  • [13] Robust Super-Resolution Volume Reconstruction From Slice Acquisitions: Application to Fetal Brain MRI
    Gholipour, Ali
    Estroff, Judy A.
    Warfield, Simon K.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (10) : 1739 - 1758
  • [14] MRI inter-slice reconstruction using super-resolution
    Greenspan, H
    Oz, G
    Kiryati, N
    Peled, S
    [J]. MAGNETIC RESONANCE IMAGING, 2002, 20 (05) : 437 - 446
  • [15] Joint super-resolution and synthesis of 1 mm isotropic MP-RAGE volumes from clinical MRI exams with scans of different orientation, resolution and contrast
    Iglesias, Juan Eugenio
    Billot, Benjamin
    Balbastre, Yael
    Tabari, Azadeh
    Conklin, John
    Gonzalez, R. Gilberto
    Alexander, C. Daniel
    Golland, Polina
    Edlow, L. Brian
    Fischl, Bruce
    [J]. NEUROIMAGE, 2021, 237
  • [16] Super-resolution reconstruction of T2-weighted thick-slice neonatal brain MRI scans
    Incebacak, N. Ceren Askin
    Sui, Yao
    Levy, Laura Gui
    Merlini, Laura
    de Almeida, Joana Sa
    Courvoisier, Sebastien
    Wallace, Tess E.
    Klauser, Antoine
    Afacan, Onur
    Warfield, Simon K.
    Huppi, Petra
    Lazeyras, Francois
    [J]. JOURNAL OF NEUROIMAGING, 2022, 32 (01) : 68 - 79
  • [17] Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM/NIST MRI system phantom
    Jiang, Yun
    Ma, Dan
    Keenan, Kathryn E.
    Stupic, Karl F.
    Gulani, Vikas
    Griswold, Mark A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1452 - 1457
  • [18] T2 Relaxometry and Diffusion Tensor Indices of the Hippocampus and Entorhinal Cortex Improve Sensitivity and Specificity of MRI to Detect Amnestic Mild Cognitive Impairment and Alzheimer's Disease Dementia
    Knight, Michael J.
    Wearn, Alfie
    Coulthard, Elizabeth
    Kauppinen, Risto A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) : 445 - 455
  • [19] Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction
    Koonjoo, N.
    Zhu, B.
    Bagnall, G. Cody
    Bhutto, D.
    Rosen, M. S.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [20] Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
    Laule, C.
    Leung, E.
    Li, D. K. B.
    Troboulsee, A. L.
    Paty, D. W.
    MacKay, A. L.
    Moore, G. R. W.
    [J]. MULTIPLE SCLEROSIS, 2006, 12 (06): : 747 - 753