Performance of transport ventilator with patient-triggered ventilation

被引:21
作者
Miyoshi, E
Fujino, Y
Mashimo, T
Nishimura, M
机构
[1] Osaka Univ Hosp, Intens Care Unit, Suita, Osaka 5650871, Japan
[2] Osaka Univ Hosp, Dept Anesthesiol, Suita, Osaka 5650871, Japan
关键词
ARDS; transport; ventilator performance; work of breathing;
D O I
10.1378/chest.118.4.1109
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Transport ventilators with inspiratory triggering functions and pressure support-control modes have recently become commercially available. We evaluated these ventilators in comparison with a standard ICU ventilator. Study design: Laboratory study with a mechanical lung model. Methods: We compared the performance of four transport ventilators (model 740, Mallinckrodt, Pleasanton, CA; TBird, Bird Products Corp, Palm Springs, CA; LTV1000, Pulmonetic Systems, Colton, CA; Esprit, Respironics, Vista, CA) with a standard ICU ventilator (model 7200ae; Mallinckrodt) using a test lung that simulated spontaneous breathing (compliance, 48.8 mL/cm H2O; resistance, 5 cm H2O/L/s). The settings of ventilators were positive end-expiratory pressure (PEEP) of 0 or 5 cm H2O, and pressure support (PS) of 0 or 10 cm H2O. The settings of the test lung were inspiratory time of 1 s, respiratory rate of 1.0/min, peak inspiratory flow of 40, 60, and 80 L/min. To evaluate inspiratory function at each setting, we measured the inspiratory delay time (DT), inspiratory trigger pressure (P-I), and the time for airway pressure to rise from the baseline pressure to 90% of the end-inspiratory pressure (T-90%); for expiratory function, supraplateau expiratory pressure (P-E) and the time constant (taue) for pressure decrease during exhalation were evaluated. Oxygen requirement was assessed as the time required to empty a 3.5-L oxygen tank. Results: For inspiratory triggering, four transport ventilators had DT < 100 ms, which is considered clinically satisfactory, in all the settings except for PS 0 cm H2O, PEEP 0 cm H2O, and inspiratory flow of 80 L/min with LTV1000. P-I increased only in LTV1000 when PEEP was increased from 0 to 5 cm H2O, <tau>e for the transport ventilators was >50% shorter than for the ICU ventilator except for PS 0 cm H2O and PEEP 5 cm H2O with TBird. Oxygen requirement was lowest for the Esprit, followed by the 740, LTV1000, and TBird. Conclusion: The newer Food and Drug Administration-approved transport ventilators have performance indexes comparable to the ventilator currently used in ICUs and can probably be recommended for clinical use.
引用
收藏
页码:1109 / 1115
页数:7
相关论文
共 12 条
  • [1] Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome
    Amato, MBP
    Barbas, CSV
    Medeiros, DM
    Magaldi, RB
    Schettino, GDP
    Lorenzi, G
    Kairalla, RA
    Deheinzelin, D
    Munoz, C
    Oliveira, R
    Takagaki, TY
    Carvalho, CRR
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) : 347 - 354
  • [2] COMPLICATIONS OF INTRAHOSPITAL TRANSPORT IN CRITICALLY ILL PATIENTS
    BRAMAN, SS
    DUNN, SM
    AMICO, CA
    MILLMAN, RP
    [J]. ANNALS OF INTERNAL MEDICINE, 1987, 107 (04) : 469 - 473
  • [3] Performance characteristics of bilevel pressure ventilators - A lung model study
    Bunburaphong, T
    Imanaka, H
    Nishimura, M
    Hess, D
    Kacmarek, RM
    [J]. CHEST, 1997, 111 (04) : 1050 - 1060
  • [4] COMPARISON OF BLOOD-GASES OF VENTILATED PATIENTS DURING TRANSPORT
    GERVAIS, HW
    EBERLE, B
    KONIETZKE, D
    HENNES, HJ
    DICK, W
    [J]. CRITICAL CARE MEDICINE, 1987, 15 (08) : 761 - 763
  • [5] HIRSCH C, 1991, Respiratory Care, V36, P815
  • [6] COMPARISON OF BLOOD-GASES DURING TRANSPORT USING 2 METHODS OF VENTILATORY SUPPORT
    HURST, JM
    DAVIS, K
    BRANSON, RD
    JOHANNIGMAN, JA
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1989, 29 (12) : 1637 - 1640
  • [7] Home versus intensive care pressure support devices - Experimental and clinical comparison
    Lofaso, F
    Brochard, L
    Hang, T
    Lorino, H
    Harf, A
    Isabey, D
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (05) : 1591 - 1599
  • [8] THE RESPONSE OF FLOW-TRIGGERED INFANT VENTILATORS
    NISHIMURA, M
    HESS, D
    KACMAREK, RM
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (06) : 1901 - 1909
  • [9] CONSENSUS CONFERENCE ON MECHANICAL VENTILATION - JANUARY 28-30, 1993 AT NORTHBROOK, ILLINOIS, USA .1.
    SLUTSKY, AS
    [J]. INTENSIVE CARE MEDICINE, 1994, 20 (01) : 64 - 79
  • [10] TOBIN MJ, 1994, PRINCIPLES PRACTICE, P239