共 50 条
Development of a modified QuEChERS method for the determination of veterinary antibiotics in swine manure by liquid chromatography tandem mass spectrometry
被引:68
|作者:
Guo, Chunna
[1
]
Wang, Mingru
[1
]
Xiao, Hui
[1
]
Huai, Binbin
[1
]
Wang, Feng
[1
]
Pan, Guangfang
[1
]
Liao, Xiaoping
[1
]
Liu, Yahong
[1
,2
,3
]
机构:
[1] South China Agr Univ, Natl Risk Assessment Lab Antimicrobial Resistance, Guangzhou, Guangdong, Peoples R China
[2] South China Agr Univ, Coll Vet Med, Lab Vet Pharmacol, Guangzhou 510642, Guangdong, Peoples R China
[3] Jiangsu Coinnovat Ctr Prevent & Control Important, Yangzhou, Jiangsu, Peoples R China
来源:
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
|
2016年
/
1027卷
基金:
中国国家自然科学基金;
关键词:
QuEChERS;
Veterinary antibiotics;
Liquid chromatography tandem mass;
Swine manure;
RESISTANCE GENES;
ANIMAL MANURE;
EXTRACTION;
SOIL;
ELECTROSPRAY;
RESIDUES;
TETRACYCLINES;
SULFONAMIDES;
VALIDATION;
MATRICES;
D O I:
10.1016/j.jchromb.2016.05.034
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A QuEChERS (quick, easy, cheap, effective, rugged and safe) based methodology was developed for the rapid, simultaneous quantification and identification of 26 veterinary drugs in swine manure by liquid chromatography tandem mass spectrometry. The selected antibiotics included tetracyclines, sulfonamides, macrolides, fluoroquinolones, lincosamides and pleuromutilins. This is the first study to determine pleuromutilin levels in manure. The QuEChERS process involved two simple steps. First, sample extraction with methanol: acetonitrile: 0.1 M EDTA-McIlvaine buffer followed by phase separation with MgSO4: NaCl addition. The supernatant was then extracted and cleaned by dispersive solid-phase extraction using a primary-secondary amine (PSA) and octadecylsilane (C-18) support. The proposed method provides a linearity in the range of 1-500 ng mL(-1) and linear regression coefficients (r) were greater than 0.996. MDL and MQL ranged between 0.01-1.86 mu g kg(-1) and 0.05-5.91 mu g kg(-1), respectively. Recoveries ranged from 61.39 to 105.65% with the exception of sulfaquinoxaline (55.7-56.8%) and valnemulin (33.7-37.7%). This method resulted in good precision (repeatability and reproducibility) and relative standard deviations less than 17% within the same day, and lower than 20% between days. The method was then applied to study the swine manure samples collected from Guangdong, China. Chlortetracycline, tetracycline, doxycycline, sulfadimidine and tilmicosin were detected in all samples indicating high residuals in manure. In fact tilmicosin was detected at 14400 mu g kg(-1) suggesting that prudent treatment of manure should be conducted to prevent environmental contamination. In conclusion, this workflow can provide a simpler and more cost-effective alternative to conventional methods and is compatible with processing large sample numbers over a short time period. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文