Influence of test specimen on experimental characterization of timber-concrete composite joints

被引:28
作者
Carvalho, Eliene Pires [1 ]
Mantilla Carrasco, Edgar V. [2 ]
机构
[1] Ctr Fed Educacao Tecnol Minas Gerais CEFET, Acad Civil Engn Dept, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Dept Struct Engn, Belo Horizonte, MG, Brazil
关键词
Timber-concrete joints; Shear strength; Push-out; Test methods;
D O I
10.1016/j.conbuildmat.2009.12.036
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Load-carrying capacity of timber-concrete composite joints is usually evaluated using shear tests, which still lack specific standards. Regulations EN 26891 [1] and ASTM D 5652 [2] are usually used, both for timber joints, or EUROCODE 4 [3] for steel-concrete composite joints. Questions about test execution and arrangement of specimens are frequent and recurrent [4-6]. Steel-concrete composite structures already have a standard shear test for joints (push-out), described in Johnson and Anderson [7]. These authors also discussed the many differences in the results of shear tests because of differences in test methods before EUROCODE 4 [3] standardization. This paper presents some questions about the arrangement of test specimens for shear tests in timber-concrete joints. An experimental program was performed for this reason. The aim of the work was to compare shear test results using two different series of specimens most utilized in a review of the literature: the push-out type with concrete center and timber sides and the push-out type with timber center and concrete sides. 8.0, 10.0 and 12.5 mm diameter corrugated bars were used as connectors. Eucalyptus grandis Brazilian hardwood timber glulam was used. Two-component epoxy adhesive was used to glue the connectors into the timber. Average cylinder compressive strength of the concrete was 25 MPa (28 days old). Reinforcement was 6.0 mm diameter 500 MPa-yield-stress corrugated bars. The results showed that test specimen arrangement influenced the strength and deformation characteristics of timber-concrete composite joints. The specimen with the best shear strength was the concrete-wood-concrete type, similar to those used in steel-concrete composite structures. Since the arrangement of test specimen is an important factor in joint tests, it is recommended that further efforts be made towards standardization. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1313 / 1322
页数:10
相关论文
共 19 条
[11]  
EN, EN 1994-1-1:2004
[12]  
Faust T., 1999, PROPERTIES COMPOSITE, P231
[13]  
Heiduschke A, 2003, FOREST PROD J, V53, P74
[14]  
HOLSCHEMACHER K, 2002, APPL STEEL FIBRE REI, P161
[15]  
JOHNSON RP, 1993, DESIGNERS HDB EURO 1, V4
[16]   Benefits of timber-concrete composite action in rural bridges [J].
Mascia, NT ;
Soriano, J .
MATERIALS AND STRUCTURES, 2004, 37 (266) :122-128
[17]   Experimental study of a composite wood-concrete beam with the INSA-Hilti new flexible shear connector [J].
Mungwa, MS ;
Jullien, JF ;
Foudjet, A ;
Hentges, G .
CONSTRUCTION AND BUILDING MATERIALS, 1999, 13 (07) :371-382
[18]  
Weaver CA, 1999, THESIS U MAINE
[19]  
Yttrup PJ, 2005, CONCRETE ENHANCED TI