Target volume segmentation of PET images by an iterative method based on threshold value

被引:2
作者
Castro, P. [1 ]
Huerga, C. [2 ]
Glaria, L. A. [3 ]
Plaza, R. [2 ]
Rodado, S. [4 ]
Marin, M. D. [4 ]
Manas, A. [3 ]
Serrada, A. [4 ]
Nunez, L. [1 ]
机构
[1] Hosp Univ Puerta Hierro Majadahonda, Serv Radiofis & Protecc Radiol, Madrid, Spain
[2] Hosp Univ La Paz, Serv Radiofis & Radioprotecc, Madrid, Spain
[3] Hosp Univ La Paz, Serv Oncol Radioterap, Madrid, Spain
[4] Hosp Univ La Paz, Nucl Med Serv, Madrid, Spain
来源
REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR | 2014年 / 33卷 / 06期
关键词
PET; Target volume delineation; Segmentation; Thresholding; Iterative method; POSITRON-EMISSION-TOMOGRAPHY; CELL LUNG-CANCER; TO-BACKGROUND RATIO; RADIOTHERAPY; DELINEATION; TUMOR; DEFINITION; CT; FUSION; MOTION;
D O I
10.1016/j.remn.2014.02.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: An automatic segmentation method is presented for PET images based on an iterative approximation by threshold value that includes the influence of both lesion size and background present during the acquisition. Material and methods: Optimal threshold values that represent a correct segmentation of volumes were determined based on a PET phantom study that contained different sizes spheres and different known radiation environments. These optimal values were normalized to background and adjusted by regression techniques to a two-variable function: lesion volume and signal-to-background ratio (SBR). This adjustment function was used to build an iterative segmentation method and then, based in this mention, a procedure of automatic delineation was proposed. This procedure was validated on phantom images and its viability was confirmed by retrospectively applying it on two oncology patients. Results: The resulting adjustment function obtained had a linear dependence with the SBR and was inversely proportional and negative with the volume. During the validation of the proposed method, it was found that the volume deviations respect to its real value and CT volume were below 10% and 9%, respectively, except for lesions with a volume below 0.6 ml. Conclusions: The automatic segmentation method proposed can be applied in clinical practice to tumor radiotherapy treatment planning in a simple and reliable way with a precision close to the resolution of PET images. (C) 2013 Elsevier Espana, S.L.U. and SEMNIM. All rights reserved.
引用
收藏
页码:331 / 339
页数:9
相关论文
共 50 条
  • [21] Accuracy of metabolic volume and total glycolysis among six threshold-based target segmentation algorithms
    Nakaichi, Tetsu
    Yamashita, Shozo
    Kawakami, Wataru
    Yamamoto, Haruki
    Sasaki, Masayuki
    Yokoyama, Kunihiko
    [J]. ANNALS OF NUCLEAR MEDICINE, 2020, 34 (08) : 583 - 594
  • [22] Unsupervised cluster-based method for segmenting biological tumour volume of laryngeal tumours in 18F-FDG-PET images
    Tafsast, Abdelghani
    Hadjili, Mohamed Laid
    Bouakaz, Ayache
    Benoudjit, Nabil
    [J]. IET IMAGE PROCESSING, 2017, 11 (06) : 389 - 396
  • [23] Influence of different contributions of scatter and attenuation on the threshold values in contrast-based algorithms for volume segmentation
    Matheoud, Roberta
    Della Monica, Patrizia
    Secco, Chiara
    Loi, Gianfranco
    Krengli, Marco
    Inglese, Eugenio
    Brambilla, Marco
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (01): : 44 - 51
  • [24] THE THRESHOLD SEGMENTATION METHOD OF SEA SHIPS IMAGES
    Fahmi, Shakeeb S.
    Seliverstov, Svyatoslav A.
    Visloguzov, Victor V.
    Krymskii, Vitalii V.
    [J]. MARINE INTELLECTUAL TECHNOLOGIES, 2019, 4 (02): : 69 - 78
  • [25] Generic and robust method for automatic segmentation of PET images using an active contour model
    Zhuang, Mingzan
    Dierckx, Rudi A. J. O.
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4483 - 4494
  • [26] An Edge-Detection Method Based on Adaptive Canny Algorithm and Iterative Segmentation Threshold
    Song Qiang
    Lin Guoying
    Ma Jingqi
    [J]. PROCEEDINGS OF 2016 2ND INTERNATIONAL CONFERENCE ON CONTROL SCIENCE AND SYSTEMS ENGINEERING (ICCSSE), 2016, : 64 - 67
  • [27] An innovative iterative thresholding algorithm for tumour segmentation and volumetric quantification on SPECT images: Monte Carlo-based methodology and validation
    Pacilio, M.
    Basile, C.
    Shcherbinin, S.
    Caselli, F.
    Ventroni, G.
    Aragno, D.
    Mango, L.
    Santini, E.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3050 - 3061
  • [28] HIGHLY PRECISE PARTIAL VOLUME CORRECTION FOR PET IMAGES: AN ITERATIVE APPROACH VIA SHAPE CONSISTENCY
    Xu, Ziyue
    Bagci, Ulas
    Gao, Mingchen
    Mollura, Daniel J.
    [J]. 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1196 - 1199
  • [29] Impact of PET and MRI threshold-based tumor volume segmentation on patient-specific targeted radionuclide therapy dosimetry using CLR1404
    Besemer, Abigail E.
    Titz, Benjamin
    Grudzinski, Joseph J.
    Weichert, Jamey P.
    Kuo, John S.
    Robins, H. Ian
    Hall, Lance T.
    Bednarz, Bryan P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (15) : 6008 - 6025
  • [30] A fast circle detection method based on threshold segmentation and validity check for FPC images
    Luo, Jiaxiang
    Chen, Xuchao
    Hu, Yueming
    [J]. 2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 3214 - 3217