A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

被引:95
作者
Zhang, Ling [1 ]
Morita, Shigeru [2 ,3 ]
Xu, Zong [1 ]
Wu, Zhenwei [1 ]
Zhang, Pengfei [1 ]
Wu, Chengrui [1 ]
Gao, Wei [1 ]
Ohishi, Tetsutarou [2 ,3 ]
Goto, Motoshi [2 ,3 ]
Shen, Junsong [1 ]
Chen, Yingjie [1 ]
Liu, Xiang [1 ]
Wang, Yumin [1 ]
Dong, Chunfeng [4 ]
Zhang, Hongmin [3 ]
Huang, Xianli [3 ]
Gong, Xianzu [1 ]
Hu, Liqun [1 ]
Chen, Junlin [1 ]
Zhang, Xiaodong [1 ]
Wan, Baonian [1 ]
Li, Jiangang [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230026, Anhui, Peoples R China
[2] Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
[3] Grad Univ Adv Studies, Dept Fus Sci, Toki, Gifu 5095292, Japan
[4] Southwestern Inst Phys, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
DENSITY PROFILE;
D O I
10.1063/1.4937723
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 angstrom wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87 degrees. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 x 6.6 mm(2) and pixel numbers of 1024 x 255 (26 x 26 mu m(2)/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Delta lambda(0) = 3-4 pixels, where Delta lambda(0) is defined as full width at the foot position of a spectral line, is obtained at the 80-400 angstrom wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 angstrom for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:10
相关论文
共 23 条
  • [1] Grazing-incidence spectrometer for soft x-ray and extreme ultraviolet spectroscopy on the National Spherical Torus Experiment
    Beiersdorfer, P.
    Bitter, M.
    Roquemore, L.
    Lepson, J. K.
    Cu, M. -F.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10)
  • [2] Time-resolved x-ray and extreme ultraviolate spectrometer for use on the National Spherical Torus Experiment
    Beiersdorfer, P.
    Lepson, J. K.
    Bitter, M.
    Hill, K. W.
    Roquemore, L.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
  • [3] Zeff first measurements in EAST with a multi-channel visible bremsstrahlung new system
    Chen, Yingjie
    Wu, Zhenwei
    Gao, Wei
    Zhang, Ling
    Zha, Wenqing
    [J]. FUSION ENGINEERING AND DESIGN, 2013, 88 (11) : 2825 - 2829
  • [4] Characteristics of an absolutely calibrated flat-field extreme ultraviolet spectrometer in the 10-130 Å range for fusion plasma diagnostics
    Chowdhuri, Malay Bikas
    Morita, Shigeru
    Goto, Motoshi
    [J]. APPLIED OPTICS, 2008, 47 (02) : 135 - 146
  • [5] Spectroscopic comparison between 1200 grooves/mm ruled and holographic gratings of a flat-field spectrometer and its absolute sensitivity calibration using bremsstrahlung continuum
    Chowdhuri, Malay Bikas
    Morita, Shigeru
    Goto, Motoshi
    Nishimura, Hiroaki
    Nagai, Keiji
    Fujioka, Shinsuke
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (02)
  • [6] Space-Resolved VUV and EUV Spectrometers in HL-2A
    Cui Zhengying
    Zhou Hangyu
    Morita, S.
    Fu Bingzhong
    Sun Ping
    Gao Yadong
    Goto, M.
    Xu Yuan
    Dong Chunfeng
    Yang Qingwei
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (02) : 110 - 114
  • [7] Space-resolved vacuum ultraviolet spectrometer system for edge impurity and temperature profile measurement in HL-2A
    Cui, Zhengying
    Morita, Shigeru
    Fu, Bingzhong
    Huang, Yuan
    Sun, Ping
    Gao, Yadong
    Xu, Yuan
    Dong, Chunfeng
    Lu, Ping
    Wang, Quanming
    Ding, Xuantong
    Yang, Qingwei
    Duan, Xuru
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (04)
  • [8] Dong C. F., 2012, PLASMA FUSION RES, V7
  • [9] Dong CF., 2011, PLASMA FUSION RES, V6, P2402078, DOI [10.1585/pfr.6.2402078, DOI 10.1585/PFR.6.2402078]
  • [10] Absolute intensity calibration of flat-field space-resolved extreme ultraviolet spectrometer using radial profiles of visible and extreme ultraviolet bremsstrahlung continuum emitted from high-density plasmas in Large Helical Device
    Dong, Chunfeng
    Morita, Shigeru
    Goto, Motoshi
    Wang, Erhui
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (11)