Experimental study of attenuation properties of normoxic polymer gel dosimeters

被引:53
作者
Brindha, S [1 ]
Venning, AJ
Hill, B
Baldock, C
机构
[1] Christian Med Coll & Hosp, Dept Radiat Oncol, Vellore 632004, Tamil Nadu, India
[2] Queensland Univ Technol, Sch Phys & Chem Sci, Brisbane, Qld 4001, Australia
[3] Canberra Hosp, Med Phys Sect, Biomed Engn Serv, Woden, ACT 2606, Australia
[4] Univ Sydney, Inst Med Phys, Sydney, NSW 2006, Australia
关键词
D O I
10.1088/0031-9155/49/20/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The change in linear attenuation coefficient with absorbed dose has been investigated for aqueous polyacrylamide, gelatine and tetrakis (PAGAT) and aqueous methacrylic acid, gelatine and tetrakis (MAGAT) normoxic polymer gel dosimeters using tetrakis (hydroxy methyl) phosphonium chloride as the antioxidant. The measured linear attenuation coefficient increased linearly with absorbed dose up to 15 Gy for PAGAT gels and 10 Gy for MAGAT gels. Computerized tomography (CT) numbers or Hounsfield units (H) were calculated from the linear attenuation coefficients and compared with values obtained using a CT scanner. Both calculated and measured CT numbers followed a similar pattern when fitted with a biexponential curve. The CT numbers obtained from linear attenuation measurements were found to be greater than that obtained with the CT scanner for both PAGAT and MAGAT polymer gels. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters measured on a CT scanner were calculated to be (0.85 +/- 0.08) H Gy(-1) and (0.31 +/- 0.03) H Gy(-1), respectively. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters from attenuation measurements were found to be (1.10 +/- 0.66) H Gy(-1) and (0.34 +/- 0.01) H Gy(-1), respectively.
引用
收藏
页码:N353 / N361
页数:9
相关论文
共 29 条
  • [1] [Anonymous], 2003, PHYS RAD THERAPY
  • [2] Audet C, 2002, J Appl Clin Med Phys, V3, P110, DOI 10.1120/1.1461916
  • [3] Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
    Baldock, C
    Burford, RP
    Billingham, N
    Wagner, GS
    Patval, S
    Badawi, RD
    Keevil, SF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) : 695 - 702
  • [4] Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method
    Baldock C.
    Harris P.J.
    Piercy A.R.
    Healy B.
    [J]. Australasian Physics & Engineering Sciences in Medicine, 2001, 24 (1): : 19 - 30
  • [5] Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer
    De Deene, Y
    De Wagter, C
    Van Duyse, B
    Derycke, S
    De Neve, W
    Achten, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) : 283 - 291
  • [6] De Deene Y, 2002, PHYS MED BIOL, V47, P2459, DOI 10.1088/0031-9155/47/14/307
  • [7] De Deene Y, 2002, PHYS MED BIOL, V47, P3441, DOI 10.1088/0031-9155/47/19/301
  • [8] De Deene Y, 2000, PHYS MED BIOL, V45, P859, DOI 10.1088/0031-9155/45/4/304
  • [9] *DOSGEL, 2001, P 2 INT C RAD GEL DO
  • [10] *DOSGEL, 2004, P 3 INT C RAD GEL DO