Peak exposures in aluminium potrooms: instrument development and field calibration

被引:7
作者
Carter, SR [1 ]
Seixas, NS [1 ]
Thompson, ML [1 ]
Yost, MG [1 ]
机构
[1] Univ Washington, Dept Occupat & Environm Hlth Sci, Seattle, WA 98195 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2004年 / 6卷 / 11期
关键词
D O I
10.1039/b406846g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas'' instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.
引用
收藏
页码:932 / 937
页数:6
相关论文
共 17 条
  • [1] Aho AV., 1988, AWK PROGRAMMING LANG
  • [2] Exposures in the alumina and primary aluminium industry: An historical review
    Benke, G
    Abramson, M
    Sim, M
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1998, 42 (03) : 173 - 189
  • [3] Bernstein IL, 1999, ASTHMA WORKPLACE
  • [4] Box G, 1976, TIME SERIES ANAL FOR
  • [5] BURGESS WA, 1995, RECOGNITION HLTH HAZ
  • [6] CARTER SR, 2004, UNPUB
  • [7] *CIT TECHN LTD, 1999, TOX GAS SENS OP INST
  • [8] DANIELS W, 1995, NIOSH HLTH HAZARD EV
  • [9] FREON AND HALOGENATED HYDROCARBON DETECTION WITH ELECTROCHEMICAL SENSORS
    KOMIYA, H
    KIMURA, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 68 - 72
  • [10] MIDTTUN O, 1960, ACTA ALLERGOLICA, V15, P208