Displacement of the epiglottis during intubation with the Pentax-AWS Airway Scope

被引:5
作者
Suzuki, Akihiro [1 ]
Katsumi, Norifumi [1 ]
Honda, Takashi [1 ]
Sasakawa, Tomoki [1 ]
Kunisawa, Takayuki [1 ]
Henderson, John J. [2 ]
Iwasaki, Hiroshi [1 ]
机构
[1] Asahikawa Med Coll, Dept Anesthesiol & Crit Care Med, Asahikawa, Hokkaido 0788510, Japan
[2] Gartnavel Royal Hosp, Dept Anaesthesia, Glasgow, Lanark, Scotland
关键词
Pentax-AWS; Airway Scope; Folding epiglottis; Epiglottis displacement; TRACHEAL INTUBATION; LARYNGOSCOPE;
D O I
10.1007/s00540-009-0826-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Pentax-AWS system is a rigid indirect video laryngoscope with integrated tube guidance. Complications associated with this device are not well understood. We report two cases of epiglottis malposition during intubation with the Pentax-AWS. The standard technique of using the Pentax-AWS system involves direct elevation of the epiglottis for exposure of the vocal cords. The blade tip should be passed posterior to the epiglottis for laryngeal exposure, but pressure on the anterior surface of the epiglottis by the tip can rarely happen even during the correct maneuver. Although the Pentax-AWS provides clear images of the airway structures, it is sometimes difficult to observe the epiglottis continuously because the camera is located beneath the blade tip. Consequently, the view of the epiglottis from the camera may be impeded by the blade tip and may result in undiagnosed epiglottis malposition. The AWS's structural feature and its approach to the larynx can be associated with increased chance of unexpected epiglottis folding. It is particularly important to confirm normal position of the epiglottis during withdrawal of the device to prevent this complication.
引用
收藏
页码:124 / 127
页数:4
相关论文
共 10 条
  • [1] Potential damage to the larynx associated with light-guided intubation: A case and series of fiberoptic examinations
    Aoyama, K
    Takenaka, I
    Nagaoka, E
    Kadoya, T
    Sata, T
    Shigematsu, A
    [J]. ANESTHESIOLOGY, 2001, 94 (01) : 165 - 167
  • [2] BRIMACOMBE J, 2005, LARYNGEAL MASK ANEST, P73
  • [3] Questions about the Macintosh laryngoscope and technique of laryngoscopy
    Henderson, JJ
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (01) : 2 - 5
  • [4] Description and first clinical application of AirWay Scope for tracheal intubation
    Koyama, Jun-ichi
    Aoyama, Tatsuro
    Kusano, Yoshikazu
    Seguchi, Tatsuya
    Kawagishi, Kyutaro
    Iwashita, Tomomi
    Okamoto, Kazufumi
    Okudera, Hiroshi
    Takasuna, Hiroshi
    Hongo, Kazuhiro
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2006, 18 (04) : 247 - 250
  • [5] Folding of the epiglottis - An unusual complication to be recognized after laryngoscopic endotracheal intubation
    Lin, TS
    Chen, CH
    Yang, MW
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (06) : 469 - 471
  • [6] Jaw thrust manoeuvre for repositioning the epiglottis down folded by the ILM
    Murashima, K
    Fukutome, T
    [J]. ANAESTHESIA, 2000, 55 (09) : 921 - 922
  • [7] Unexpected difficult airway
    Ramachandran, K
    Bhishma, R
    [J]. ANAESTHESIA, 2003, 58 (04) : 392 - 393
  • [8] The Pentax-AWS® rigid indirect video laryngoscope:: clinical assessment of performance in 320 cases
    Suzuki, A.
    Toyama, Y.
    Katsumi, N.
    Kunisawa, T.
    Sasaki, R.
    Hirota, K.
    Henderson, J. J.
    Iwasaki, H.
    [J]. ANAESTHESIA, 2008, 63 (06) : 641 - 647
  • [9] Tips for intubation with the Pentax-AWS® Rigid Indirect Laryngoscope in morbidly obese patients
    Suzuki, A.
    Terao, M.
    Fujita, S.
    Henderson, J. J.
    [J]. ANAESTHESIA, 2008, 63 (04) : 442 - 444
  • [10] Malposition of the epiglottis after tracheal intubation via the intubating laryngeal mask
    Takenaka, I
    Aoyama, K
    Nagaoka, E
    Seto, A
    Niijima, K
    Kadoya, T
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1999, 83 (06) : 962 - 963