Auditory Temporal Acuity Probed With Cochlear Implant Stimulation and Cortical Recording

被引:29
作者
Kirby, Alana E. [1 ,2 ]
Middlebrooks, John C. [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Otolaryngol Head & Neck Surg, Irvine, CA 92697 USA
[2] Univ Michigan, Kresge Hearing Res Inst, Dept Otolaryngol Head & Neck Surg, Ann Arbor, MI 48109 USA
关键词
CHANNEL GAP DETECTION; WITHIN-CHANNEL; PULSE-RATE; PSYCHOPHYSICAL RECOVERY; MODULATION DETECTION; INFERIOR COLLICULUS; NEURAL RESPONSES; NERVE FIBERS; MASKING; CORTEX;
D O I
10.1152/jn.00794.2009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Kirby AE, Middlebrooks JC. Auditory temporal acuity probed with cochlear implant stimulation and cortical recording. J Neurophysiol 103: 531-542, 2010. First published November 18, 2009; doi: 10.1152/jn.00794.2009. Cochlear implants stimulate the auditory nerve with amplitude-modulated (AM) electric pulse trains. Pulse rates >2,000 pulses per second (pps) have been hypothesized to enhance transmission of temporal information. Recent studies, however, have shown that higher pulse rates impair phase locking to sinusoidal AM in the auditory cortex and impair perceptual modulation detection. Here, we investigated the effects of high pulse rates on the temporal acuity of transmission of pulse trains to the auditory cortex. In anesthetized guinea pigs, signal-detection analysis was used to measure the thresholds for detection of gaps in pulse trains at rates of 254, 1,017, and 4,069 pps and in acoustic noise. Gap-detection thresholds decreased by an order of magnitude with increases in pulse rate from 254 to 4,069 pps. Such a pulse-rate dependence would likely influence speech reception through clinical speech processors. To elucidate the neural mechanisms of gap detection, we measured recovery from forward masking after a 196.6-ms pulse train. Recovery from masking was faster at higher carrier pulse rates and masking increased linearly with current level. We fit the data with a dualexponential recovery function, consistent with a peripheral and a more central process. High-rate pulse trains evoked less central masking, possibly due to adaptation of the response in the auditory nerve. Neither gap detection nor forward masking varied with cortical depth, indicating that these processes are likely subcortical. These results indicate that gap detection and modulation detection are mediated by two separate neural mechanisms.
引用
收藏
页码:531 / 542
页数:12
相关论文
共 39 条
[1]  
[Anonymous], 1988, Signal Detection Theory and Psychophysics
[2]   Electrically evoked whole nerve action potentials in ineraid cochlear implant users: Responses to different stimulating electrode configurations and comparison to psychophysical responses [J].
Brown, CJ ;
Abbas, PJ ;
Borland, J ;
Bertschy, MR .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (03) :453-467
[3]   Gap detection by early-deafened cochlear-implant subjects [J].
Busby, PA ;
Clark, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1841-1852
[4]   Within-channel gap detection using dissimilar markers in cochlear implant listeners [J].
Chatterjee, M ;
Fu, QJ ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (05) :2515-2519
[5]   Temporal mechanisms underlying recovery from forward masking in multielectrode-implant listeners [J].
Chatterjee, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1853-1863
[6]   Neural responses in primary auditory cortex mimic psychophysical, across-frequency-channel, gap-detection thresholds [J].
Eggermont, JJ .
JOURNAL OF NEUROPHYSIOLOGY, 2000, 84 (03) :1453-1463
[7]   The Modulation Transfer Function for Speech Intelligibility [J].
Elliott, Taffeta M. ;
Theunissen, Frederic E. .
PLOS COMPUTATIONAL BIOLOGY, 2009, 5 (03)
[8]   Temporal processing and speech recognition in cochlear implant users [J].
Fu, QJ .
NEUROREPORT, 2002, 13 (13) :1635-1639
[9]   Effects of stimulation rate, mode and level on modulation detection by cochlear implant users [J].
Galvin, JJ ;
Fu, QJ .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2005, 6 (03) :269-279
[10]   Within- and across-channel gap detection in cochlear implant listeners [J].
Grose, John H. ;
Buss, Emily .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (06) :3651-3658