Simultaneous determination of catecholamines, uric acid and ascorbic acid at physiological levels using poly(N-methylpyrrole)/Pd-nanoclusters sensor

被引:154
作者
Atta, Nada F. [1 ]
El-Kady, Maher F. [1 ]
Galal, Ahmed [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Giza 12613, Egypt
关键词
Pd nanoclusters; Electrochemical sensor; Poly(N-methylpyrrole); Catecholamine neurotransmitters; Ascorbic acid; Uric acid; GLASSY-CARBON ELECTRODE; PALLADIUM NANOPARTICLES; CONDUCTING POLYMERS; ELECTROCATALYTIC PROPERTIES; PLATINUM NANOPARTICLES; SELECTIVE DETECTION; POLYPYRROLE; DOPAMINE; NEUROTRANSMITTERS; FILMS;
D O I
10.1016/j.ab.2010.01.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An interesting electrochemical sensor has been constructed by the electrodeposition of palladium nanoclusters (Pd-nano) on poly(N-methylpyrrole) (PMPy) film-coated platinum (Pt) electrode. Cyclic voltammetry, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy were used to characterize the properties of the modified electrode. It was demonstrated that the electroactivity of the modified electrode depends strongly on the electrosynthesis conditions of the PMPy film and Pd-nano. Moreover, the modified electrode exhibits strong electrocatalytic activity toward the oxidation of a mixture of dopamine (DA), ascorbic acid (AA), and uric acid (UA) with obvious reduction of overpotentials. The simultaneous analysis of this mixture at conventional (Pt, gold [Au], and glassy carbon) electrodes usually struggles. However, three well-resolved oxidation peaks for AA, DA, and UA with large peak separations allow this modified electrode to individually or simultaneously analyze AA, DA, and UA by using differential pulse voltammetry (DPV) with good stability, sensitivity, and selectivity. This sensor is also ideal for the simultaneous analysis of AA, UA and either of epinephrine (E), norepinephrine (NE) or L-DOPA. Additionally, the sensor shows strong electrocatalytic activity towards acetaminophen (ACOP) and other organic compounds. The calibration curves for AA, DA, and UA were obtained in the ranges of 0.05 to 1 mM, 0.1 to 10 mu M, and 0.5 to 20 mu M, respectively. The detection limits (signal/noise [S/N] = 3) were 7 mu M, 12 nM, and 27 nM for AA, DA, and UA, respectively. The practical application of the modified electrode was demonstrated by measuring the concentrations of AA, DA, and UA in injection sample, human serum, and human urine samples, respectively, with satisfactory results. The reliability and stability of the modified electrode gave a good possibility for applying the technique to routine analysis of AA, DA, and UA in clinical tests. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:78 / 88
页数:11
相关论文
共 61 条
  • [11] Electrochemical deposition of platinum nanoparticles on different carbon supports and conducting polymers
    Dominguez-Dominguez, Sonia
    Pardilla, Joaquin Arias
    Murcia, Angel Berenguer
    Morallon, Emilia
    Cazorla-Amoros, Diego
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (02) : 259 - 268
  • [12] Covalent modification of carbon electrodes for voltammetric differentiation of dopamine and ascorbic acid
    Downard, AJ
    Roddick, AD
    Bond, AM
    [J]. ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 303 - 310
  • [13] DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
  • [14] Determination of ascorbic acid in a mixture of ascorbic acid and uric acid at a chemically modified electrode
    Gao, ZQ
    Siow, KS
    Ng, A
    Zhang, YM
    [J]. ANALYTICA CHIMICA ACTA, 1997, 343 (1-2) : 49 - 57
  • [15] Electrochemistry of conductive polymers XXXV: Electrical and morphological characteristics of polypyrrole films prepared in aqueous media studied by current sensing atomic force microscopy
    Han, DH
    Lee, HJ
    Park, SM
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (15) : 3085 - 3092
  • [16] Deposition and electrocatalytic properties of platinum nanoparticals on carbon nanotubes for methanol electrooxidation
    He, ZB
    Chen, JH
    Liu, DY
    Tang, H
    Deng, W
    Kuang, WF
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2004, 85 (2-3) : 396 - 401
  • [17] Role of doping, ions in the corrosion protection of iron by polypyrrole films
    Hien, NTL
    Garcia, B
    Pailleret, A
    Deslouis, C
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (7-8) : 1747 - 1755
  • [18] Simultaneous electrochemical determination of dopamine, uric acid and ascorbic acid using palladium nanoparticle-loaded carbon nanofibers modified electrode
    Huang, Jianshe
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) : 632 - 637
  • [19] Chemically modified electrodes based on macrocyclic compounds for determination of Vitamin C by electrocatalytic oxidation
    Ijeri, VS
    Jaiswal, PV
    Srivastava, AK
    [J]. ANALYTICA CHIMICA ACTA, 2001, 439 (02) : 291 - 297
  • [20] Comparative study of the behavior of anions in polypyrrole films
    Johanson, U
    Marandi, A
    Tamm, T
    Tamm, J
    [J]. ELECTROCHIMICA ACTA, 2005, 50 (7-8) : 1523 - 1528