THE EFFECTIVENESS OF WATER MIST IN THE FUNCTIONING OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

被引:0
|
作者
Nyashina, Galina S. [1 ]
机构
[1] Natl Res Tomsk Polytech Univ, Tomsk 634050, Russia
来源
SMART GRIDS 2015 | 2015年 / 37卷
关键词
D O I
10.1051/matecconf/20153701038
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Currently, one of the most perspective directions fire protection is the use of water mist extinguishing agents. An experimental study of phase transformations of water mist droplets (radius of 50 - 500 microns) in motion in a high-temperature (500 - 1800 K), typical products of combustion of petroleum products (gasoline, kerosene, acetone, alcohol). Use high speed (the speed of recording at least 105 images per second) and optical methods of recording streams of liquid and gas medium. The influence of the parameters of the test process (the initial temperature and the initial droplet size) at the rate of evaporation of atomized water under these conditions. The optimum droplet size histograms in extinguishing fluid stream, providing evaporation of atomized water flow.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] The effectiveness of low-pressure water mist systems on battery fire extinguishing
    Kraus-Namrozy, Natalia
    Brzezinska, Dorota
    Brzezinska, Maria
    Brzezinski, Mateusz
    4TH EUROPEAN SYMPOSIUM ON FIRE SAFETY SCIENCE, 2024, 2885
  • [2] EXPERIMENTAL EVALUATION THE EFFECTIVENESS OF WATER MIST FIRE EXTINGUISHING SYSTEMS AT OIL AND GAS INDUSTRY
    Nyashina, G. S.
    Medvedev, V. V.
    Shevyrev, S. A.
    Vysokomornaya, O. V.
    THERMOPHYSICAL BASIS OF ENERGY TECHNOLOGIES 2015, 2016, 110
  • [3] Experimental evaluation of the effectiveness of water mist automated fire extinguishing systems for oil transportation
    Glushkov, D. O.
    Nyashina, G. S.
    Strizhak, P. A.
    Volkov, R. S.
    XIX INTERNATIONAL SCIENTIFIC SYMPOSIUM IN HONOR OF ACADEMICIAN M.A. USOV PROBLEMS OF GEOLOGY AND SUBSURFACE DEVELOPMENT, 2015, 27
  • [4] Experimental Investigation of Extinguishing Fire Effectiveness on Kerosene Pool Fire With Water Mist
    Zuo Qiuling
    Wang Gongzhong
    Li Jingshan
    Fu Aiqing
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 858 - 862
  • [5] Study on the effect of mist flux on water mist fire extinguishing
    Liu, Yang
    Fu, Zhixi
    Zheng, Guanghui
    Chen, Peng
    FIRE SAFETY JOURNAL, 2022, 130
  • [6] Preliminary study on extinguishing shielded fire with water mist
    Liu, Yangpeng
    Wang, Xishi
    Liu, Tong
    Ma, Jing
    Li, Guochun
    Zhao, Zihao
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 141 (141) : 344 - 354
  • [7] Hybrid fire extinguishing systems using water mist and inert gas during extinguishing A-type fires
    Drzymala, Tomasz
    Galaj, Jerzy
    PRZEMYSL CHEMICZNY, 2018, 97 (06): : 963 - 968
  • [8] EXPERTS APPLAUD THE EFFECTIVENESS OF THE WATER MIST EXTINGUISHING CONCEPT
    不详
    MER-MARINE ENGINEERS REVIEW, 1995, : 16 - 17
  • [9] Performance evaluation of portable water mist fire extinguishing system
    Chang, Wen-Yao
    Fu, Ping-Kun
    Chen, Chiun-Hsun
    Shu, Yi-Liang
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 896 - 900
  • [10] X-Mist: a new Korean water-mist fire extinguishing system
    不详
    NAVAL ARCHITECT, 2003, : 13 - 13