Raman spectroscopy-based identification of toxoid vaccine products

被引:12
作者
Silge, Anja [1 ,2 ,3 ]
Bocklitz, Thomas [1 ,2 ,3 ,4 ]
Becker, Bjoern [5 ]
Matheis, Walter [5 ]
Popp, Juergen [1 ,2 ,3 ,4 ]
Bekeredjian-Ding, Isabelle [5 ]
机构
[1] Friedrich Schiller Univ Jena, Inst Phys Chem, Helmholtzweg 4, D-07743 Jena, Germany
[2] Friedrich Schiller Univ Jena, Abbe Ctr Photon, Helmholtzweg 4, D-07743 Jena, Germany
[3] InfectoGnost Res Campus Jena, Ctr Appl Res, Philosophenweg 7, D-07743 Jena, Germany
[4] Leibniz Inst Photon Technol, Albert Einstein Str 9, D-07745 Jena, Germany
[5] Paul Ehrlich Inst, Div Microbiol, Paul Ehrlichstr 51-59, D-63225 Langen, Germany
关键词
PROCESS ANALYTICAL TECHNOLOGY; SPECTRA; QUANTIFICATION; CONSISTENCY; TOOL;
D O I
10.1038/s41541-018-0088-y
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Vaccines are complex biomedicines. Manufacturing is time consuming and requires a high level of quality control (QC) to guarantee consistent safety and potency. An increasing global demand has led to the need to reduce time and cost of manufacturing. The evolving concepts for QC and the upcoming threat of falsification of biomedicines define a new need for methods that allow the fast and reliable identification of vaccines. Raman spectroscopy is a non-destructive technology already established in QC of classical medicines. We hypothesized that Raman spectroscopy could be used for identification and differentiation of vaccine products. Raman maps obtained from air-dried samples of combination vaccines containing antigens from tetanus, diphtheria and pertussis (DTaP vaccines) were summarized to compile product-specific Raman signatures. Sources of technical variance were emphasized to evaluate the robustness and sensitivity in downstream data analysis. The data management approach corrects for spatial inhomogeneities in the dried sample while offering a proper representation of the original samples inherent chemical signature. Reproducibility of the identification was validated by a leave-one-replicate-out cross-validation. The results highlighted the high specificity and sensitivity of Raman measurements in identifying DTaP vaccine products. The results pave the way for further exploitation of the Raman technology for identification of vaccines in batch release and cases of suspected falsification.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Real Time Monitoring of Multiple Parameters in Mammalian Cell Culture Bioreactors Using an In-Line Raman Spectroscopy Probe [J].
Abu-Absi, Nicholas R. ;
Kenty, Brian M. ;
Cuellar, Maryann Ehly ;
Borys, Michael C. ;
Sakhamuri, Sivakesava ;
Strachan, David J. ;
Hausladen, Michael C. ;
Li, Zheng Jian .
BIOTECHNOLOGY AND BIOENGINEERING, 2011, 108 (05) :1215-1221
[2]   Vibrational spectra and assignments of 2-phenylethanol and 2-phenoxyethanol [J].
Badawi, Hassan M. .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 82 (01) :63-68
[3]   Aluminum salts in vaccines - US perspective [J].
Baylor, NW ;
Egan, W ;
Richman, P .
VACCINE, 2002, 20 :S18-S23
[4]   How to pre-process Raman spectra for reliable and stable models? [J].
Bocklitz, Thomas ;
Walter, Angela ;
Hartmann, Katharina ;
Roesch, Petra ;
Popp, Juergen .
ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) :47-56
[5]   Raman Based Molecular Imaging and Analytics: A Magic Bullet for Biomedical Applications!? [J].
Bocklitz, Thomas W. ;
Guo, Shuxia ;
Ryabchykov, Oleg ;
Vogler, Nadine ;
Popp, Juergen .
ANALYTICAL CHEMISTRY, 2016, 88 (01) :133-151
[6]   Drivers and barriers in the consistency approach for vaccine batch release testing: Report of an international workshop [J].
Bruysters, Martijn W. P. ;
Schiffelers, Marie-Jeanne ;
Hoonakker, Marieke ;
Jungbaeck, Carmen ;
Ragan, Ian ;
Rommel, Eddy ;
van der Stappen, Ton ;
Viviani, Laura ;
Hessel, Ellen V. ;
Akkermans, Arnoud M. ;
Vandebriel, Rob J. .
BIOLOGICALS, 2017, 48 :1-5
[7]   Fault diagnosis in chemical processes using Fisher discriminant analysis, discriminant partial least squares, and principal component analysis [J].
Chiang, LH ;
Russell, EL ;
Braatz, RD .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 50 (02) :243-252
[8]   Chemometric analysis of Raman spectroscopic data for process control applications [J].
Cooper, JB .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 46 (02) :231-247
[9]   Multivariate data analysis applied to spectroscopy: Potential application to juice and fruit quality [J].
Cozzolino, D. ;
Cynkar, W. U. ;
Shah, N. ;
Smith, P. .
FOOD RESEARCH INTERNATIONAL, 2011, 44 (07) :1888-1896
[10]   Emerging technologies for the non-invasive characterization of physical-mechanical properties of tablets [J].
Dave, Vivek S. ;
Shahin, Hend I. ;
Youngren-Ortiz, Susanne R. ;
Chougule, Mahavir B. ;
Haware, Rahul V. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 532 (01) :299-312