Experimental investigation on heating performance of solar integrated air source heat pump

被引:37
作者
Dong, Xu [1 ]
Tian, Qi [1 ]
Li, Zhen [1 ]
机构
[1] Dept Bldg Environm & Energy Applicat Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar finned tube evaporator; Solar integrated air source heat pump; Integrated part load value; Seasonal part load value; Relative size; LATENT-HEAT; SYSTEM; ENERGY; SIMULATION; HOUSE;
D O I
10.1016/j.applthermaleng.2017.05.183
中图分类号
O414.1 [热力学];
学科分类号
摘要
The solar integrated air source heat pump with R407c is proposed and investigated on the heating performance. The prototype developed to compare with the same type of conventional air source heat pump is suitable for marketization at the present. Based on the -9 degrees C to -11 degrees C average outdoor dry-bulb temperature including the -9.9 degrees C for the design of space heating in Taiyuan, the 35-65% average outdoor relative humidity, the 115-135 W/m(2) average solar irradiance, the 15 degrees C initial water temperature and the condensing temperature from 30 degrees C to 55 degrees C, the heating performances with the part load rate of 25%, 50%, 75% and 100% are investigated, respectively. The average integrated part load value of solar integrated air source heat pump is 2.54 which is 14.9% higher than the 2.21 of conventional air source heat pump, while the average seasonal part load value of the solar integrated one is 2.53 which is 15.5% higher than the 2.19 of the conventional one. The solar integrated air source heat pump with no water pipe exposed to outdoor environment is safe and appropriate for the narrow and vertical outdoor installation space of high-rise building users to meet their individual demand of domestic hot water or space heating. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 38 条
[1]  
American Air-Conditioning and Refrigeration Institute, 1998, 5505901998 ARI
[2]  
American Air-Conditioning Heating and Refrigeration Institute, 2011, 550590 ARI
[3]   Exergetic and Thermoeconomic Analyses of Solar Air Heating Processes Using a Parabolic Trough Collector [J].
Angel Hernandez-Roman, Miguel ;
Manzano-Ramirez, Alejandro ;
Pineda-Pinon, Jorge ;
Ortega-Moody, Jorge .
ENTROPY, 2014, 16 (08) :4612-4625
[4]   THEORETICAL ENERGY AND EXERGY ANALYSES OF SOLAR ASSISTED HEAT PUMP SPACE HEATING SYSTEM [J].
Atmaca, Ibrahim ;
Kocak, Sezgi .
THERMAL SCIENCE, 2014, 18 :S417-S427
[5]   Solar assisted heat pump systems for low temperature water heating applications: A systematic review [J].
Buker, Mahmut Sami ;
Riffat, Saffa B. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 :399-413
[6]   Numerical simulation and experimental validation of indirect expansion solar-assisted multi-functional heat pump [J].
Cai, Jingyong ;
Ji, Jie ;
Wang, Yunyun ;
Huang, Wenzhu .
RENEWABLE ENERGY, 2016, 93 :280-290
[7]   Modeling of a residential house coupled with a dual source heat pump using TRNSYS software [J].
Chargui, R. ;
Sammouda, H. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 81 :384-399
[8]   Solar-assisted heat pump - A sustainable system for low-temperature water heating applications [J].
Chaturvedi, S. K. ;
Gagrani, V. D. ;
Abdel-Salam, T. M. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 77 :550-557
[10]   Simulation analysis on dynamic performance of a combined solar/air dual source heat pump water heater [J].
Deng, Weishi ;
Yu, Jianlin .
ENERGY CONVERSION AND MANAGEMENT, 2016, 120 :378-387