Minimally invasive cardiac output technologies in the ICU: putting it all together

被引:17
|
作者
Clement, Ramon P. [1 ]
Vos, Jaap J. [2 ]
Scheeren, Thomas W. L. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesiol, Hanzepl 1,POB 30 001, NL-9700 RB Groningen, Netherlands
关键词
cardiac output; circulatory shock; functional haemodynamic monitoring; minimally invasive cardiac output monitoring; CRITICALLY-ILL PATIENTS; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; STROKE VOLUME VARIATION; POLAR PLOT METHODOLOGY; 4TH GENERATION FLOTRAC; PULSE CONTOUR ANALYSIS; TRANSPULMONARY THERMODILUTION; APPLANATION TONOMETRY; MONITORING DEVICES;
D O I
10.1097/MCC.0000000000000417
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of reviewHaemodynamic monitoring is a cornerstone in the diagnosis and evaluation of treatment in critically ill patients in circulatory distress. The interest in using minimally invasive cardiac output monitors is growing. The purpose of this review is to discuss the currently available devices to provide an overview of their validation studies in order to answer the question whether these devices are ready for implementation in clinical practice.Recent findingsCurrent evidence shows that minimally invasive cardiac output monitoring devices are not yet interchangeable with (trans)pulmonary thermodilution in measuring cardiac output. However, validation studies are generally single centre, are based on small sample sizes in heterogeneous groups, and differ in the statistical methods used.SummaryMinimally and noninvasive monitoring devices may not be sufficiently accurate to replace (trans)pulmonary thermodilution in estimating cardiac output. The current paradigm shift to explore trending ability rather than investigating agreement of absolute values alone is to be applauded. Future research should focus on the effectiveness of these devices in the context of (functional) haemodynamic monitoring before adoption into clinical practice can be recommended.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 50 条
  • [31] Comparison of bioreactance non-invasive cardiac output measurements with cardiac magnetic resonance imaging
    Trinkmann, F.
    Schneider, C.
    Michels, J. D.
    Stach, K.
    Doesch, C.
    Schoenberg, S. O.
    Borggrefe, M.
    Saur, J.
    Papavassiliu, T.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 769 - 776
  • [32] Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography
    Peyton, Philip J.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) : 121 - 132
  • [33] Evaluation of a minimally invasive non-calibrated pulse contour cardiac output monitor (FloTrac/Vigileo) in anaesthetized dogs
    Bektas, Rima N.
    Kutter, Annette P. N.
    Hartnack, Sonja
    Jud, Rahel S.
    Schnyder, Manuela
    Matos, Jose M.
    Bettschart-Wolfensberger, Regula
    VETERINARY ANAESTHESIA AND ANALGESIA, 2012, 39 (05) : 464 - 471
  • [34] Mini invasive hemodynamic monitoring: from arterial pressure to cardiac output
    Della Rocca, Giorgio
    Cecconi, Maurizio
    Costa, Maria Gabriella
    SIGNA VITAE, 2008, 3 : 7 - 9
  • [35] Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography
    Philip J. Peyton
    Journal of Clinical Monitoring and Computing, 2012, 26 : 121 - 132
  • [36] Noninvasive whole-body electrical bioimpedance cardiac output and invasive thermodilution cardiac output in high-risk surgical patients
    Imhoff, M
    Lehner, JH
    Löhlein, D
    CRITICAL CARE MEDICINE, 2000, 28 (08) : 2812 - 2818
  • [37] Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output
    Trinkmann, Frederik
    Berger, Manuel
    Doesch, Christina
    Papavassiliu, Theano
    Schoenberg, Stefan O.
    Borggrefe, Martin
    Kaden, Jens J.
    Saur, Joachim
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (04) : 399 - 408
  • [38] Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system
    Stéphane Thierry
    Dominique Thebert
    Elsa Brocas
    Fereshte Razzaghi
    Andry Van de Louw
    Daniel Loisance
    Jean Louis Teboul
    Intensive Care Medicine, 2003, 29 : 2096 - 2099
  • [39] Minimally invasive determination of cardiac output by transthoracic bioimpedance, partial carbon dioxide rebreathing, and transesophageal Doppler echocardiography in beagle dogs
    Yamashita, Kazuto
    Ueyama, Yukie
    Miyoshi, Kenjiro
    Igarashi, Ritsuyo
    Kushiro, Tokiko
    Umar, Mohammed A.
    Muir, William W.
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2007, 69 (01) : 43 - 47
  • [40] Non-Invasive Cardiac Output Monitoring in Cardiogenic Shock: The NICOM Study
    Rali, Aniket S.
    Buechler, Tyler
    Van Gotten, Bridget
    Waters, Andrew
    Shah, Zubair
    Haglund, Nicholas
    Sauer, Andrew
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (02) : 160 - 165