Hypothermic machine perfusion in kidney transplantation

被引:58
作者
De Deken, Julie [1 ,2 ]
Kocabayoglu, Peri [3 ]
Moers, Cyril [4 ]
机构
[1] Klinikum Saarbrucken, Dept Gen Visceral Thorac & Pediat Surg, Saarbrucken, Germany
[2] Katholieke Univ Leuven, Lab Abdominal Transplantat, Dept Microbiol & Immunol, Leuven, Belgium
[3] Univ Duisburg Essen, Univ Hosp Essen, Dept Gen Visceral & Transplant Surg, Fac Med, Essen, Germany
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, NL-9700 RB Groningen, Netherlands
关键词
graft function; hypothermic machine perfusion; kidney transplantation; COLD-STORAGE; PORCINE KIDNEYS; CARDIAC DEATH; PRESERVATION; ALLOCATION; DONATION; DONORS;
D O I
10.1097/MOT.0000000000000306
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Purpose of reviewThis article summarizes novel developments in hypothermic machine perfusion (HMP) as an organ preservation modality for kidneys recovered from deceased donors.Recent findingsHMP has undergone a renaissance in recent years. This renewed interest has arisen parallel to a shift in paradigms; not only optimal preservation of an often marginal quality graft is required, but also improved graft function and tools to predict the latter are expected from HMP. The focus of attention in this field is currently drawn to the protection of endothelial integrity by means of additives to the perfusion solution, improvement of the HMP solution, choice of temperature, duration of perfusion, and machine settings. HMP may offer the opportunity to assess aspects of graft viability before transplantation, which can potentially aid preselection of grafts based on characteristics such as perfusate biomarkers, as well as measurement of machine perfusion dynamics parameters.SummaryHMP has proven to be beneficial as a kidney preservation method for all types of renal grafts, most notably those retrieved from extended criteria donors. Large numbers of variables during HMP, such as duration, machine settings and additives to the perfusion solution are currently being investigated to improve renal function and graft survival. In addition, the search for biomarkers has become a focus of attention to predict graft function posttransplant.
引用
收藏
页码:294 / 300
页数:7
相关论文
共 30 条
[1]   CURRENT CONCEPTS - RENAL PRESERVATION [J].
BELZER, FO .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 291 (08) :402-404
[2]   Analysis of Perfusates During Hypothermic Machine Perfusion by NMR Spectroscopy: A Potential Tool for Predicting Kidney Graft Outcome [J].
Bon, Delphine ;
Claire, Billault ;
Thuillier, Raphael ;
Hebrard, William ;
Boildieu, Nadege ;
Celhay, Olivier ;
Irani, Jacques ;
Seguin, Francois ;
Hauet, Thierry .
TRANSPLANTATION, 2014, 97 (08) :810-816
[3]   Novel preservation methods to increase the quality of older kidneys [J].
Brat, Aukje ;
Pol, Robert A. ;
Leuvenink, Henri G. D. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2015, 20 (04) :438-443
[4]   Oxygen Consumption During Oxygenated Hypothermic Perfusion as a Measure of Donor Organ Viability [J].
Bunegin, Leonid ;
Tolstykh, Gleb P. ;
Gelineau, Jerry F. ;
Cosimi, A. Benedict ;
Anderson, Lisa M. .
ASAIO JOURNAL, 2013, 59 (04) :427-432
[5]   Mechanistic Analysis of Nonoxygenated Hypothermic Machine Perfusion's Protection on Warm Ischemic Kidney Uncovers Greater eNOS Phosphorylation and Vasodilation [J].
Chatauret, N. ;
Coudroy, R. ;
Delpech, P. O. ;
Vandebrouck, C. ;
Hosni, S. ;
Scepi, M. ;
Hauet, T. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (11) :2500-2514
[6]   Hypothermic machine perfusion improves Doppler ultrasonography resistive indices and long-term allograft function after renal transplantation: a single-centre analysis [J].
Dion, Marie S. ;
McGregor, Thomas B. ;
McAlister, Vivian C. ;
Luke, Patrick P. ;
Sener, Alp .
BJU INTERNATIONAL, 2015, 116 (06) :932-937
[7]   One or 4 h of "in-house" reconditioning by machine perfusion after cold storage improve reperfusion parameters in porcine kidneys [J].
Gallinat, Anja ;
Efferz, Patrik ;
Paul, Andreas ;
Minor, Thomas .
TRANSPLANT INTERNATIONAL, 2014, 27 (11) :1214-1219
[8]   Role of Pulsatility in Hypothermic Reconditioning of Porcine Kidney Grafts by Machine Perfusion After Cold Storage [J].
Gallinat, Anja ;
Fox, Mario ;
Lueer, Bastian ;
Efferz, Patrik ;
Paul, Andreas ;
Minor, Thomas .
TRANSPLANTATION, 2013, 96 (06) :538-542
[9]   Metabolomic Analysis of Perfusate During Hypothermic Machine Perfusion of Human Cadaveric Kidneys [J].
Guy, Alison J. ;
Nath, Jay ;
Cobbold, Mark ;
Ludwig, Christian ;
Tennant, Daniel A. ;
Inston, Nicholas G. ;
Ready, Andrew R. .
TRANSPLANTATION, 2015, 99 (04) :754-759
[10]   Glutathione S-Transferase Iso-Enzymes in Perfusate From Pumped Kidneys Are Associated With Delayed Graft Function [J].
Hall, I. E. ;
Bhangoo, R. S. ;
Reese, P. P. ;
Doshi, M. D. ;
Weng, F. L. ;
Hong, K. ;
Lin, H. ;
Han, G. ;
Hasz, R. D. ;
Goldstein, M. J. ;
Schroeppel, B. ;
Parikh, C. R. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 (04) :886-896