Neutron-Beam-Shaping Assembly for Boron Neutron-Capture Therapy

被引:16
作者
Zaidi, L. [1 ,2 ]
Kashaeva, E. A. [1 ,3 ]
Lezhnin, S. I. [1 ,4 ,5 ]
Malyshkin, G. N. [1 ,3 ]
Samarin, S. I. [1 ,3 ]
Sycheva, T. V. [1 ]
Taskaev, S. Yu. [1 ,5 ]
Frolov, S. A. [1 ,3 ]
机构
[1] Russian Acad Sci, Siberian Branch, Budker Inst Nucl Phys, Pr Akad Lavrentieva 11, Novosibirsk 630090, Russia
[2] Univ Sci & Technol Houari Boumediene, BP 32 El Alia 16111, Bab Ezzouar 16111, Algeria
[3] Zababakhin All Russian Sci Res Inst Tech Phys VNI, POB 245, Snezhinsk, Chelyabinsk Obl, Russia
[4] Russian Acad Sci, Novosibirsk Branch, Nucl Safety Inst, Pr Akad Lavrentieva 1, Novosibirsk 630090, Russia
[5] Novosibirsk State Univ, Ul Pirogova 2, Novosibirsk 630090, Russia
基金
俄罗斯科学基金会;
关键词
OPTIMIZATION; BNCT; PARAMETERS; DESIGN;
D O I
10.1134/S106377881701015X
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a compositemoderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeVare shown to permit obtaining a high-quality therapeutic neutron beam.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 19 条
  • [1] Abramovich S., 1989, NUCL PHYS CONSTANTS
  • [2] Current progress and future prospects of the VITA based neutron source
    Aleynik, V.
    Bashkirtsev, A.
    Kanygin, V.
    Kasatov, D.
    Kuznetsov, A.
    Makarov, A.
    Schudlo, I.
    Sorokin, I.
    Taskaev, S.
    Tiunov, M.
    [J]. APPLIED RADIATION AND ISOTOPES, 2014, 88 : 177 - 179
  • [3] [Anonymous], P 12 INT C NEUTR CAP
  • [4] [Anonymous], 2012, NEUTRON CAPTURE THER
  • [5] Optimization parameters for BDE in BNCT using near threshold 7Li(p,n)7 Be direct neutrons
    Bengua, G
    Kobayashi, T
    Tanaka, K
    Nakagawa, Y
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1003 - 1008
  • [6] Brednikhin S. A., 2012, 201204 NSI RAS
  • [7] Design of a beam shaping assembly and preliminary modelling of a treatment room for accelerator-based BNCT at CNEA
    Burlon, A. A.
    Girola, S.
    Valda, A. A.
    Minsky, D. M.
    Kreiner, A. J.
    Sanchez, G.
    [J]. APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1688 - 1691
  • [8] Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models
    Goorley, JT
    Kiger, WS
    Zamenhof, RG
    [J]. MEDICAL PHYSICS, 2002, 29 (02) : 145 - 156
  • [9] Fission reactor neutron sources for neutron capture therapy - a critical review
    Harling, OK
    Riley, KJ
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2003, 62 (01) : 7 - 17
  • [10] Hawk A, 2002, RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, P253