Phenol removal capacity of RO with and without pre-treatment

被引:20
作者
Ipek, U [1 ]
机构
[1] Firat Univ, Fac Engn, Dept Environm Engn, TR-23119 Elazig, Turkey
来源
FILTRATION & SEPARATION | 2004年 / 41卷 / 07期
关键词
D O I
10.1016/S0015-1882(04)00321-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of traditional pre-treatment methods, such as depth filtration and granular activated carbon (GAC), on the phenol removal capacity of reverse osmosis (RO) was investigated. Two experimental series were performed in the pH range of 4-9. Firstly, a phenol- containing water sample was passed through a RO membrane alone. A sample was then passed through a depth filter and a GAC unit prior to it being passed through the RO membrane. The results indicate that the best RO phenol removal efficiency occurs with GAC pre-treatment. The phenol concentration in the RO effluent was reduced to less than 0.25 mg/l.
引用
收藏
页码:39 / 40
页数:2
相关论文
共 5 条
  • [1] Removal of organic substances from aqueous solutions by reagent enhanced reverse osmosis
    Goncharuk, VV
    Kucheruk, DD
    Kochkodan, VM
    Badekha, VP
    [J]. DESALINATION, 2002, 143 (01) : 45 - 51
  • [2] The characteristics of crosslinked PAA composite membrane for separation of aqueous organic solutions by reverse osmosis
    Huang, JC
    Guo, QH
    Ohya, H
    Fang, J
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1998, 144 (1-2) : 1 - 11
  • [3] SAWYER CN, 1978, CHEM ENV ENG WATER R
  • [4] Snell FD., 1971, COLORIMETRIC METHODS
  • [5] Stanley, 2000, ENV CHEM