Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture

被引:139
作者
Muhs, Bart E.
Balm, Ron
White, Geoffrey H.
Verhagen, Hence J. M.
机构
[1] Univ Utrecht, Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[2] NYU, Sch Med, Div Vasc Surg, New York, NY USA
[3] Acad Med Ctr, Dept Vasc Surg, Amsterdam, Netherlands
[4] Royal Prince Alfred Hosp, Dept Vasc Surg, Sydney, NSW, Australia
关键词
D O I
10.1016/j.jvs.2006.12.023
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The potentially devastating complication of total or near total thoracic endoprosthesis collapse has been described with the TAG device (W. L. Gore & Associates, Flagstaff, Ariz). This rare complication has resulted in a warning to clinicians and speculation about the etiology of this problem. This report evaluates potential causative anatomic factors that may increase the probability of endoprosthesis collapse in patients undergoing endovascular thoracic aneurysm repair (TEVAR). Methods. Preoperative and postoperative computed tomography scans were collected worldwide representing six patients who had experienced radiologically confirmed TAG endoprosthesis collapse. These were compared with a matched cohort of five patients with a TAG endoprosthesis in the same anatomic position in which no collapse occurred. Anatomic variables of aortic arch angulation, apposition, intraluminal lip length, proximal aortic diameter, distal aortic diameter, intragraft aortic diameter, percentage of oversizing, and angle of the proximal endograft to the aortic arch were compared between groups. Differences between groups were determined using the Student t test, with P < .05 considered significant. Results. The two groups (collapse vs no collapse) were evenly matched demographically, and all underwent endoluminal treatment with the TAG device, with no differences in gender, graft position in the aorta, operative indication, or age (P = NS). Distal sealing zone aortic diameter +/- standard deviation of 18.9 +/- 1.7 mm vs 22.7 +/- 2.7 mm and minimum aortic diameter within the endograft of 18.6 +/- 1.7 mm vs 22.4 +/- 3.1 mm predicted collapse (P < .05). Proximal aortic diameter, apposition, intraluminal lip length, aortic arch angle, and angle of proximal endograft to aortic arch did not predict collapse (P = NS). Conclusion: Thoracic endograft collapse is an exceedingly rare event. In this series, endoprosthesis collapse occurred in patients who were treated outside the manufacturer's instructions for use for minimum required aortic diameter. Although distal aortic diameter and minimum intragraft aortic diameter predicted collapse, other variables may also influence this complication but were not significant owing to potential type II statistical errors. In the future, caution should be exercised when contemplating TEVAR in patients with small (< 23 mm) aortic diameters.
引用
收藏
页码:655 / 661
页数:7
相关论文
共 19 条
[1]   Traumatic aortic rupture [J].
Balm, R. ;
Legemate, D. A. .
BRITISH JOURNAL OF SURGERY, 2006, 93 (09) :1033-1034
[2]   ENDOVASCULAR GRAFT PLACEMENT IN EXPERIMENTAL DISSECTION OF THE THORACIC AORTA [J].
BOUDGHENE, F ;
SAPOVAL, M ;
BIGOT, JM ;
MICHEL, JB .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (04) :501-507
[3]  
Chabbert V, 2003, J ENDOVASC THER, V10, P494, DOI 10.1583/1545-1550(2003)010<0494:MOOTAS>2.0.CO
[4]  
2
[5]   Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience [J].
Criado, FJ ;
Clark, NS ;
Barnatan, MF .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (06) :1121-1127
[6]   Complications of endovascular repair of high-risk and emergent descending thoracic aortic aneurysms and dissections [J].
Hansen, CJ ;
Bui, H ;
Donayre, CE ;
Aziz, I ;
Kim, B ;
Kopchok, G ;
Walot, I ;
Lee, J ;
Lippmann, M ;
White, RA .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (02) :228-234
[7]   Endovascular management of traumatic ruptures of the thoracic aorta: A retrospective multicenter analysis of 28 cases in The Netherlands [J].
Hoornweg, Liselot L. ;
Dinkelman, Maarten K. ;
Goslings, J. Carel ;
Reekers, Jim A. ;
Verhagen, Hence J. M. ;
Verhoeven, Eric L. ;
Schurink, Geert Willem H. ;
Balm, Ron .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (06) :1096-1102
[8]   Collapse of a stent-graft following treatment of a traumatic thoracic aortic rupture [J].
Idu, MM ;
Reekers, JA ;
Balm, R ;
Ponsen, KJ ;
de Mol, BAJM ;
Legemate, DA .
JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (04) :503-507
[9]   Late complications of thoracic endografts [J].
Kasirajan, K ;
Milner, R ;
Chaikof, EL .
JOURNAL OF VASCULAR SURGERY, 2006, 43 :94A-99A
[10]   Thoracic endografts: Procedural steps, technical pitfalls and how to avoid them [J].
Kasirajan, Karthikeshwar .
SEMINARS IN VASCULAR SURGERY, 2006, 19 (01) :3-10