Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation

被引:20
|
作者
Liu, Yi-Da [1 ]
Li, Qiang [1 ]
Zhou, Zhuhuang [2 ,3 ]
Yeah, Yao-Wen [4 ]
Chang, Chien-Cheng [4 ]
Lee, Chia-Yen [5 ]
Tsui, Po-Hsiang [6 ,7 ,8 ,9 ]
机构
[1] Tianjin Univ, Sch Elect Informat Engn, Tianjin, Peoples R China
[2] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing, Peoples R China
[3] Beijing Univ Technol, Fac Informat Technol, Beijing, Peoples R China
[4] Natl Taiwan Univ, Inst Appl Mech, Taipei, Taiwan
[5] Natl United Univ, Dept Elect Engn, Miaoli, Taiwan
[6] Chang Gung Univ, Coll Med, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[7] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan, Taiwan
[8] Chang Gung Mem Hosp Linkou, Taoyuan, Taiwan
[9] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
来源
PLOS ONE | 2017年 / 12卷 / 08期
基金
中国国家自然科学基金;
关键词
THERMAL ABLATION; ECHO-SHIFTS; ATTENUATION; DEPENDENCE; CANCER; TISSUE;
D O I
10.1371/journal.pone.0182457
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiofrequency ablation (RFA) has been widely used as an alternative treatment modality for liver tumors. Monitoring the temperature distribution in the tissue during RFA is required to assess the thermal dosage. Ultrasound temperature imaging based on the detection of echo time shifts has received the most attention in the past decade. The coefficient k, connecting the temperature change and the echo time shift, is a medium-dependent parameter used to describe the confounding effects of changes in the speed of sound and thermal expansion as temperature increases. The current algorithm of temperature estimate based on echo time shift detection typically uses a constant k, resulting in estimation errors when ablation temperatures are higher than 50 degrees C. This study proposes an adaptive-k algorithm that enables the automatic adjustment of the coefficient k during ultrasound temperature monitoring of RFA. To verify the proposed algorithm, RFA experiments on in vitro porcine liver samples (total n = 15) were performed using ablation powers of 10, 15, and 20 W. During RFA, a clinical ultrasound system equipped with a 7.5-MHz linear transducer was used to collect backscattered signals for ultrasound temperature imaging using the constant-and adaptive-k algorithms. Concurrently, an infrared imaging system and thermocouples were used to measure surface temperature distribution of the sample and internal ablation temperatures for comparisons with ultrasound estimates. Experimental results demonstrated that the proposed adaptive-k method improved the performance in visualizing the temperature distribution. In particular, the estimation errors were also reduced even when the temperature of the tissue is higher than 50 degrees C. The proposed adaptive-k ultrasound temperature imaging strategy has potential to serve as a thermal dosage evaluation tool for monitoring high-temperature RFA.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography
    Pandeya, Ganga D.
    Greuter, Marcel J. W.
    de Jong, Koert P.
    Schmidt, Bernhard
    Flohr, Thomas
    Oudkerk, Matthijs
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 356 - 360
  • [32] In Vivo Noninvasive Temperature Measurement by B-Mode Ultrasound Imaging
    Pouch, Alison M.
    Cary, Theodore W.
    Schultz, Susan M.
    Sehgal, Chandra M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (11) : 1595 - 1606
  • [33] Monitoring Radiofrequency Ablation Using Ultrasound Envelope Statistics and Shear Wave Elastography in the Periablation Period: An In Vitro Feasibility Study
    Tsui, Po-Hsiang
    Wang, Chiao-Yin
    Zhou, Zhuhuang
    Wan, Yung-Liang
    PLOS ONE, 2016, 11 (09):
  • [34] Ultrasound-guided radiofrequency ablation for papillary thyroid microcarcinoma: a retrospective analysis of 198 patients
    Wu, Rong
    Luo, Yukun
    Tang, Jie
    Yang, Ming
    Li, Jie
    Zhang, Ying
    Zhang, Mingbo
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 168 - 174
  • [35] Effectiveness of impedance monitoring during radiofrequency ablation for predicting popping
    Iida, Hiroya
    Aihara, Tsukasa
    Ikuta, Shinichi
    Yamanaka, Naoki
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (41) : 5870 - 5878
  • [36] A Systemic Study on the Performance of Different Quantitative Ultrasound Imaging Techniques for Microwave Ablation Monitoring of Liver
    Yang, Guang
    Zhang, Siyuan
    Li, Xiejing
    Shen, Ting
    Jia, Xin
    Ding, Yunjie
    Zhang, Bo
    Wang, Hua
    Li, Xiaopeng
    Ren, Pengyu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [37] TOWARDS OPTICAL MONITORING OF RADIOFREQUENCY ABLATION EXTENT FOR ATRIAL FIBRILLATION
    Singh-Moon, Rajinder P.
    Hendon, Christine P.
    2015 IEEE 12TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2015, : 751 - 755
  • [38] Radiofrequency Ablation of Lung Tumors
    Casal, Roberto F.
    Tam, Alda L.
    Eapen, George A.
    CLINICS IN CHEST MEDICINE, 2010, 31 (01) : 151 - +
  • [39] Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation
    Xu, HX
    Xie, XY
    Lu, MD
    Chen, JW
    Yin, XY
    Xu, ZF
    Liu, GJ
    CLINICAL RADIOLOGY, 2004, 59 (01) : 53 - 61
  • [40] Fusion imaging-guided radiofrequency ablation for residual hepatocellular carcinoma invisible on ultrasound after transcatheter arterial chemoembolization
    Gu, Jiong-Hui
    Zhao, Qi-Yu
    He, Chang
    Ye, Zheng-Du
    Xu, Min
    Jiang, Tian-An
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 1092 - 1098