Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation

被引:20
|
作者
Liu, Yi-Da [1 ]
Li, Qiang [1 ]
Zhou, Zhuhuang [2 ,3 ]
Yeah, Yao-Wen [4 ]
Chang, Chien-Cheng [4 ]
Lee, Chia-Yen [5 ]
Tsui, Po-Hsiang [6 ,7 ,8 ,9 ]
机构
[1] Tianjin Univ, Sch Elect Informat Engn, Tianjin, Peoples R China
[2] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing, Peoples R China
[3] Beijing Univ Technol, Fac Informat Technol, Beijing, Peoples R China
[4] Natl Taiwan Univ, Inst Appl Mech, Taipei, Taiwan
[5] Natl United Univ, Dept Elect Engn, Miaoli, Taiwan
[6] Chang Gung Univ, Coll Med, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[7] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan, Taiwan
[8] Chang Gung Mem Hosp Linkou, Taoyuan, Taiwan
[9] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
来源
PLOS ONE | 2017年 / 12卷 / 08期
基金
中国国家自然科学基金;
关键词
THERMAL ABLATION; ECHO-SHIFTS; ATTENUATION; DEPENDENCE; CANCER; TISSUE;
D O I
10.1371/journal.pone.0182457
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Radiofrequency ablation (RFA) has been widely used as an alternative treatment modality for liver tumors. Monitoring the temperature distribution in the tissue during RFA is required to assess the thermal dosage. Ultrasound temperature imaging based on the detection of echo time shifts has received the most attention in the past decade. The coefficient k, connecting the temperature change and the echo time shift, is a medium-dependent parameter used to describe the confounding effects of changes in the speed of sound and thermal expansion as temperature increases. The current algorithm of temperature estimate based on echo time shift detection typically uses a constant k, resulting in estimation errors when ablation temperatures are higher than 50 degrees C. This study proposes an adaptive-k algorithm that enables the automatic adjustment of the coefficient k during ultrasound temperature monitoring of RFA. To verify the proposed algorithm, RFA experiments on in vitro porcine liver samples (total n = 15) were performed using ablation powers of 10, 15, and 20 W. During RFA, a clinical ultrasound system equipped with a 7.5-MHz linear transducer was used to collect backscattered signals for ultrasound temperature imaging using the constant-and adaptive-k algorithms. Concurrently, an infrared imaging system and thermocouples were used to measure surface temperature distribution of the sample and internal ablation temperatures for comparisons with ultrasound estimates. Experimental results demonstrated that the proposed adaptive-k method improved the performance in visualizing the temperature distribution. In particular, the estimation errors were also reduced even when the temperature of the tissue is higher than 50 degrees C. The proposed adaptive-k ultrasound temperature imaging strategy has potential to serve as a thermal dosage evaluation tool for monitoring high-temperature RFA.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation
    Zhang, Lin
    Li, Qiang
    Wang, Chiao-Yin
    Tsui, Po-Hsiang
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 548 - 558
  • [2] Monitoring radiofrequency ablation with ultrasound Nakagami imaging
    Wang, Chiao-Yin
    Geng, Xiaonan
    Yeh, Ta-Sen
    Liu, Hao-Li
    Tsui, Po-Hsiang
    MEDICAL PHYSICS, 2013, 40 (07)
  • [3] Dynamic frame selection for in vivo ultrasound temperature estimation during radiofrequency ablation
    Daniels, Matthew J.
    Varghese, Tomy
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16) : 4735 - 4753
  • [4] Comparison of ultrasound temperature imaging with infrared thermometry during radio frequency ablation
    Geng, Xiaonan
    Zhou, Zhuhuang
    Li, Qiang
    Wu, Shuicai
    Wang, Chiao-Yin
    Liu, Hao-Li
    Chuang, Ching-Cheng
    Tsui, Po-Hsiang
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (04)
  • [5] Optical Fiber Ultrasound Probe for Radiofrequency Ablation Temperature Monitoring: In-Vitro Results
    Guo, Xu
    Zhou, Jingcheng
    Du, Cong
    Wang, Xingwei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2020, 32 (12) : 689 - 692
  • [6] Phase Contrast Imaging Based Microbubble Monitoring of Radiofrequency Ablation: Anex vivoStudy
    Huang, Wei
    Lu, Jian
    Tang, Rongbiao
    Wu, Zhiyuan
    Wang, Qingbing
    Ding, Xiaoyi
    Wang, Zhongmin
    Chen, Kemin
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [7] A Novel Ultrasound Imaging Method for 2D Temperature Monitoring of Thermal Ablation
    Audigier, Chloe
    Kim, Younsu
    Boctor, Emad
    IMAGING FOR PATIENT-CUSTOMIZED SIMULATIONS AND SYSTEMS FOR POINT-OF-CARE ULTRASOUND, 2017, 10549 : 154 - 162
  • [8] Photoacoustic imaging in percutaneous radiofrequency ablation: device guidance and ablation visualization
    Francis, Kalloor Joseph
    Manohar, Srirang
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18)
  • [9] Computational Modeling of Radiofrequency Ablation: Evaluation on Ex Vivo Data Using Ultrasound Monitoring
    Audigier, Chloe
    Kim, Younsu
    Dillow, Austin
    Boctor, Emad M.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [10] Ultrasound-Guided Radiofrequency Ablation of Chemodectomas in Five Dogs
    Gomez Ochoa, Pablo
    Alferez, Maria Dolores
    de Blas, Ignacio
    Fernendes, Telmo
    Sanchez Salguero, Xavier
    Balana, Beatriz
    Melendez Lazo, Antonio
    Barbero Fernandez, Alicia
    Caivano, Domenico
    Corda, Francesca
    Corda, Andrea
    ANIMALS, 2021, 11 (10):