Feasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles

被引:5
作者
Rotenberg, Menahem Y. [1 ]
Gabay, Hovav [2 ]
Etzion, Yoram [2 ,3 ]
Cohen, Smadar [1 ,3 ,4 ]
机构
[1] Ben Gurion Univ Negev, Avram & Stella Goldstein Goren Dept Biotechnol En, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Dept Physiol & Cell Biol, Cardiac Arrhythmia Res Lab, IL-84105 Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Regenerat Med & Stem Cell Res Ctr, IL-84105 Beer Sheva, Israel
[4] Ben Gurion Univ Negev, Ilse Katz Inst Nanoscale Sci & Technol, IL-84105 Beer Sheva, Israel
关键词
VENTRICULAR-TACHYCARDIA; MECHANICAL STIMULATION; FORGOTTEN PROCEDURE; AXIAL STRETCH; HEART; COMPLICATIONS; PACEMAKERS; EFFICACY; SAFETY;
D O I
10.1038/srep24635
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-injected magnetic microparticles in the right ventricular cavity using an external electromagnet, the application of magnetic pulses generates mechanical stimulation that provokes ventricular overdrive pacing in the rat heart. This temporary pacing consistently managed to revert drug-induced bradycardia, but could only last up to several seconds in the rat model, most likely due to escape of the particles between the applied pulses using our current experimental setting. In a pig model with open chest, MEF-based pacing was induced by banging magnetic particles and has lasted for a longer time. Due to overheating of the electromagnet, we intentionally terminated the experiments after 2 min. Our results demonstrate for the first time the feasibility of external leadless temporary pacing, using injectable magnetic microparticles that are manipulated by an external electromagnet. This new approach can have important utilities in clinical settings in which immediate and painless control of cardiac rhythm is required.
引用
收藏
页数:12
相关论文
共 41 条
[1]   A high field gradient magnet for magnetic drug targeting [J].
Alexiou, Christoph ;
Diehl, Dirk ;
Henninger, Peter ;
Iro, Heinrich ;
Roeckelein, Rudolf ;
Schmidt, Wolfgang ;
Weber, Horst .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) :1527-1530
[2]   Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study [J].
Auricchio, Angelo ;
Delnoy, Peter-Paul ;
Butter, Christian ;
Brachmann, Johannes ;
Van Erven, Lieselot ;
Spitzer, Stefan ;
Moccetti, Tiziano ;
Seifert, Martin ;
Markou, Thanasie ;
Laszo, Karolyi ;
Regoli, Francois .
EUROPACE, 2014, 16 (05) :681-688
[3]   ANALYSIS OF PACEMAKER MALFUNCTION AND COMPLICATIONS OF TEMPORARY PACING IN THE CORONARY-CARE UNIT [J].
AUSTIN, JL ;
PREIS, LK ;
CRAMPTON, RS ;
BELLER, GA ;
MARTIN, RP .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (02) :301-306
[4]  
BADERMAN H, 1965, LANCET, V2, P1293
[5]   MECHANICAL STIMULATION OF HEART - ITS THERAPEUTIC VALUE IN TACHYARRHYTHMIAS [J].
BEFELER, B .
CHEST, 1978, 73 (06) :832-838
[6]   Lipid-based amphotericin B formulations: from animals to man [J].
Bekersky, I ;
Fielding, RM ;
Buell, D ;
Lawrence, I .
PHARMACEUTICAL SCIENCE & TECHNOLOGY TODAY, 1999, 2 (06) :230-236
[7]   Regional survey of temporary transvenous pacing procedures and complications [J].
Betts, TR .
POSTGRADUATE MEDICAL JOURNAL, 2003, 79 (934) :463-466
[8]  
BORNEMAN.C, 1969, DIS CHEST, V56, P83
[9]   Effect of three emergency pacing modalities on cardiac output in cardiac arrest due to ventricular asystole [J].
Chan, L ;
Reid, C ;
Taylor, B .
RESUSCITATION, 2002, 52 (01) :117-119
[10]  
Cheng GM, 2011, CIRCULATION, V124