Development of a novel electrochemical sensor based on electropolymerized molecularly imprinted polymer for selective detection of sodium lauryl sulfate in environmental waters and cosmetic products

被引:25
作者
Motia, Soukaina [1 ,2 ]
Tudor, Joan Albert [3 ]
Popescu, L. Madalina [3 ]
Piticescu, Roxana Mioara [3 ]
Bouchikhi, Benachir [1 ]
El Bari, Nezha [2 ]
机构
[1] Moulay Ismail Univ, Fac Sci, Dept Phys, Sensor Elect & Instrumentat Grp, BP 11201, Zitoune, Meknes, Morocco
[2] Moulay Ismail Univ, Fac Sci, Dept Biol, Biotechnol Agroalimentary & Biomed Anal Grp, BP 11201, Zitoune, Meknes, Morocco
[3] Natl R&D Inst Nonferrous & Rare Met, Nanostruct Mat Lab, Pantelimon, Ilfov, Romania
基金
欧盟地平线“2020”;
关键词
Sodium lauryl sulfate; Molecularly imprinted polymer; Electropolymerization; Environmental waters; Cosmetic products; UV-vis spectrophotometer; BOVINE HEMOGLOBIN RECOGNITION; DODECYL-SULFATE; ANIONIC SURFACTANTS; MODIFIED ELECTRODE; SKIN IRRITATION; HUMAN SERUM; NANOPARTICLES; CARBON; FILM; TOXICITY;
D O I
10.1016/j.jelechem.2018.03.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel molecularly imprinted polymer (MIP) sensor for the electrochemical detection of sodium lauryl sulfate (SLS) is reported. The MIP based screen-printed gold electrode (Au-SPE) was prepared by an electrochemical polymerization of 2-aminothiophenol (2-ATP) in the presence of SLS as target molecule. For control, a non-imprinted polymer (NIP) sensor was also constructed identically by omitting the SLS template. Moreover, the selectivity of the proposed MIP sensor was investigated by using analogues such as Ethylenediaminetetraacetic acid (EDTA), Tween 80 and Urea, revealing satisfactory selectivity toward SLS. The electrochemical characterization of the elaborated sensor was performed using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS) techniques. The morphology of the MIP sensor was studied by means of Atomic Force Microscopy (AFM) and Fourier Transform Infrared Spectroscopy (FTIR) methods. Some experimental parameters such as number of cycle for the electropolymerization, incubation time of 2-ATP, elution and SLS incubation time, were optimized to improve the sensor performances. Under optimal conditions, the electrochemical sensor exhibits a logarithmic working range from 0.1 to 1000 pg/mL, and a detection limit of 0.18 pg/mL. Additionally, compared with reported works, the sensor possesses remarkable properties, such as a higher sensitivity and selectivity, a good reproducibility, a wider logarithmic range, a lower detection limit and a long-term stability. As real application, the developed MIP sensor was well employed to determine SLS contents in environmental waters and cosmetic products samples. A UV-vis spectrophotometer was used as reference method. A partial least squares (PLS) technique was well employed to study the correlation between the spectrophotometer and the MR) sensor technology with a satisfactory regression coefficient (R = 0.99). The obtained results during the sensor development and applications suggested an interesting and valuable tool for environmental analysis.
引用
收藏
页码:553 / 562
页数:10
相关论文
共 49 条
[1]   Piezoelectric quartz crystal sensor for surfactant based on molecularly imprinted polypyrrole [J].
Albano, D. R. ;
Sevilla, F., III .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (01) :129-134
[2]   DIE-AWAY KINETIC-ANALYSIS OF THE CAPACITY OF EPILITHIC AND PLANKTONIC BACTERIA FROM CLEAN AND POLLUTED RIVER WATER TO BIODEGRADE SODIUM DODECYL-SULFATE [J].
ANDERSON, DJ ;
DAY, MJ ;
RUSSELL, NJ ;
WHITE, GF .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (03) :758-763
[3]   Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis [J].
Arduini, Fabiana ;
Micheli, Laura ;
Moscone, Danila ;
Palleschi, Giuseppe ;
Piermarini, Silvia ;
Ricci, Francesco ;
Volpe, Giulia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :114-126
[4]   Molecularly imprinted polymer based electrochemical detection of L-cysteine at carbon paste electrode [J].
Aswini, K. K. ;
Mohan, A. M. Vinu ;
Biju, V. M. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 :321-326
[5]   An electrochemical nanobiosensor for plasma miRNA-155, based on graphene oxide and gold nanorod, for early detection of breast cancer [J].
Azimzadeh, Mostafa ;
Rahaie, Mandi ;
Nasirizadeh, Navid ;
Ashtari, Khadijeh ;
Naderi-Manesh, Hossein .
BIOSENSORS & BIOELECTRONICS, 2016, 77 :99-106
[6]   Human and Environmental Toxicity of Sodium Lauryl Sulfate (SLS): Evidence for Safe Use in Household Cleaning Products [J].
Bondi, Cara A. M. ;
Marks, Julia L. ;
Wroblewski, Lauren B. ;
Raatikainen, Heidi S. ;
Lenox, Shannon R. ;
Gebhardt, Kay E. .
ENVIRONMENTAL HEALTH INSIGHTS, 2015, 9 :27-32
[7]   Characteristics and environmental fate of the anionic surfactant sodium lauryl ether sulphate (SLES) used as the main component in foaming agents for mechanized tunnelling [J].
Caracciolo, Anna Barra ;
Cardoni, Martina ;
Pescatore, Tanita ;
Patrolecco, Luisa .
ENVIRONMENTAL POLLUTION, 2017, 226 :94-103
[8]   In vivo assessment of cytological changes by means of reflectance confocal microscopy - demonstration of the effect of topical vitamin E on skin irritation caused by sodium lauryl sulfate [J].
Casari, Alice ;
Farnetani, Francesca ;
De Pace, Barbara ;
Losi, Amanda ;
Pittet, Jean-Christophe ;
Pellacani, Giovanni ;
Longo, Caterina .
CONTACT DERMATITIS, 2017, 76 (03) :131-137
[9]   Thin-Film Formation of Imidazolium-Based Conjugated Polydiacetylenes and Their Application for Sensing Anionic Surfactants [J].
Chen, Xiaoqiang ;
Kang, Sunwoo ;
Kim, Min Jung ;
Kim, Joohee ;
Kim, Youn Sang ;
Kim, Heejin ;
Chi, Bo ;
Kim, Sung-Jin ;
Lee, Jin Yong ;
Yoon, Juyoung .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (08) :1422-1425
[10]   Determination of Sodium Dodecyl Sulfate in Toothpastes by a PVC Matrix Membrane Sensor [J].
Devi, Sunaina ;
Chattopadhyaya, Mahesh C. .
JOURNAL OF SURFACTANTS AND DETERGENTS, 2013, 16 (03) :391-396