Bulk motion-compensated DCE-MRI for functional imaging of kidneys in newborns

被引:14
作者
Coll-Font, Jaume [1 ,2 ]
Afacan, Onur [1 ,2 ]
Chow, Jeanne S. [1 ,3 ]
Lee, Richard S. [1 ,3 ]
Stemmer, Alto [4 ]
Warfield, Simon K. [1 ,2 ]
Kurugol, Sila [1 ,2 ]
机构
[1] Boston Childrens Hosp, Radiol, Boston, MA USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Boston Childrens Hosp, Urol, Boston, MA USA
[4] Siemens Healthcare, Erlangen, Germany
关键词
DCE-MRI; motion compensation; newborn imaging; GRASP; kidney imaging; GLOMERULAR-FILTRATION; RENAL PERFUSION; GRADIENT-ECHO; RECONSTRUCTION; REGISTRATION; LIVER;
D O I
10.1002/jmri.27021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Evaluation of kidney function in newborns with hydronephrosis is important for clinical decisions. Dynamic contrast-enhanced (DCE) MRI can provide the necessary anatomical and functional information. Golden angle dynamic radial acquisition and compressed sensing reconstruction provides sufficient spatiotemporal resolution to achieve accurate parameter estimation for functional imaging of kidneys. However, bulk motion during imaging (rigid or nonrigid movement of the subject resulting in signal dropout) remains an unresolved challenge. Purpose To evaluate a motion-compensated (MoCo) DCE-MRI technique for robust evaluation of kidney function in newborns. Our method includes: 1) motion detection, 2) motion-robust image reconstruction, 3) joint realignment of the volumes, and 4) tracer-kinetic (TK) model fitting to evaluate kidney function parameters. Study Type Retrospective. Subjects Eleven newborn patients (ages <6 months, 6 female). Field Strength/Sequence 3T; dynamic "stack-of-stars" 3D fast low-angle shot (FLASH) sequence using a multichannel body-matrix coil. Assessment We evaluated the proposed technique in terms of the signal-to-noise ratio (SNR) of the reconstructed images, the presence of discontinuities in the contrast agent concentration time curves due to motion with a total variation (TV) metric and the goodness of fit of the TK model, and the standard variation of its parameters. Statistical Tests We used a paired t-test to compare the MoCo and no-MoCo results. Results The proposed MoCo method successfully detected motion and improved the SNR by 3.3 (P = 0.012) and decreased TV by 0.374 (P = 0.017) across all subjects. Moreover, it decreased nRMSE of the TK model fit for the subjects with less than five isolated bulk motion events in 6 minutes (mean 1.53, P = 0.043), but not for the subjects with more frequent events or no motion (P = 0.745 and P = 0.683). Data Conclusion Our results indicate that the proposed MoCo technique improves the image quality and accuracy of the TK model fit for subjects who present isolated bulk motion events. Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 39 条
[1]  
[Anonymous], 2017, P IEEE C COMP VIS PA
[2]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[3]  
block kai tobias, 2014, Investigative Magnetic Resonance Imaging, V18, P87
[4]   Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging [J].
Chandarana, Hersh ;
Feng, Li ;
Ream, Justin ;
Wang, Annie ;
Babb, James S. ;
Block, Kai Tobias ;
Sodickson, Daniel K. ;
Otazo, Ricardo .
INVESTIGATIVE RADIOLOGY, 2015, 50 (11) :749-756
[5]   Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI [J].
Chandarana, Hersh ;
Block, Kai T. ;
Winfeld, Matthew J. ;
Lala, Shailee V. ;
Mazori, Daniel ;
Giuffrida, Emalyn ;
Babb, James S. ;
Milla, Sarah S. .
EUROPEAN RADIOLOGY, 2014, 24 (02) :320-326
[6]  
CHEVALIER RL, 1995, SEMIN NEPHROL, V15, P353
[7]   Mechanisms of renal injury and progression of renal disease in congenital obstructive nephropathy [J].
Chevalier, Robert L. ;
Thornhill, Barbara A. ;
Forbes, Michael S. ;
Kiley, Susan C. .
PEDIATRIC NEPHROLOGY, 2010, 25 (04) :687-697
[8]  
Coll-Font J, 2019, P 27 ANN M ISMRM MON
[9]   The wild bootstrap, tamed at last [J].
Davidson, Russell ;
Flachaire, Emmanuel .
JOURNAL OF ECONOMETRICS, 2008, 146 (01) :162-169
[10]   Use of 3D DCE-MRI for the Estimation of Renal Perfusion and Glomerular Filtration Rate: An Intrasubject Comparison of FLASH and KWIC With a Comprehensive Framework for Evaluation [J].
Eikefjord, Eli ;
Andersen, Erling ;
Hodneland, Erlend ;
Zoellner, Frank ;
Lundervold, Arvid ;
Svarstad, Einar ;
Rorvik, Jarle .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :W273-W281