Comparison of measured pinch parameters versus pressure for SABALAN1 plasma focus facility against computed values using Lee model code

被引:1
作者
Karimi, F. S. [1 ]
Saviz, S. [1 ]
Ghoranneviss, M. [1 ]
Salem, M. K. [1 ]
Aghamir, F. M. [2 ]
机构
[1] Islamic Azad Univ, Sci & Res Branch, Plasma Phys Res Ctr, Tehran 1477893855, Iran
[2] Univ Tehran, Dept Phys, N Kargar Ave, Tehran 14399, Iran
来源
AIP ADVANCES | 2018年 / 8卷 / 07期
关键词
X-RAY-EMISSION; DEVICE; OPTIMIZATION; OPERATION; DYNAMICS; LENGTH;
D O I
10.1063/1.5031084
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, we have studied the effect ofworking gas pressure on plasma pinch properties in a Mather type plasma focus (2 kJ, 20 kV, 10 mu F), named SABALAN1. Argon at the various operating pressures ranging from 0.1-1.2 Torr has been used as working gas. The total current waveform has been measured for different pressures. Also, a numerical simulation was done using Lee model code to perform numerical experiments in SABALAN1. The numerical simulation was used to compute argon soft x-ray yield as a function of pressure, to anticipate the maximum soft x-ray efficiency at optimum operating gas pressure. The Lee model was configured for SABALAN1, by fitting a simulated discharge current waveform against a measured discharge current waveform was obtained by numerically integrating the output of a dI/ dt calibrated Rogowski coil. The experimental and simulation curves for plasma pinch properties have been plotted. Some of the dynamic parameters of the plasma and the characteristics of the plasma pinch have been displayed at different argon pressures in two tables. In addition, the chart of the normalized parameters of the plasma pinch has been plotted in terms of pressure. The results of experimentally measured and numerical simulation showthat better pinches with attention to their plasma pinch characteristics, generally were dependent on pressure and the best pinch is obtained at 0.6-0.7 Torr for argon at 14 kV in SABALAN1. Furthermore, in high pressures (higher than 0.7 Torr in our experiments), the discharge current can behave as short circuit discharge and resembles that of a simple L-C-R discharge which is a damped sinusoidal. Comparison of the experimental and numerical curves shows sensible agreement in some plasma pinch properties such as the time to pinch and depth of focus. The results from charts and tables have been discussed. (C) 2018 Author(s).
引用
收藏
页数:11
相关论文
共 38 条
  • [1] ASAI H, 1989, FUSION ENG DES, V7, P335
  • [2] Study of x-ray emission from a table top plasma focus and its application as an x-ray backlighter
    Beg, FN
    Ross, I
    Lorenz, A
    Worley, JF
    Dangor, AE
    Haines, MG
    [J]. JOURNAL OF APPLIED PHYSICS, 2000, 88 (06) : 3225 - 3230
  • [3] Bernard A., 1998, Journal of the Moscow Physical Society, V8, P93
  • [4] Comparative study of soft x-ray emission characteristics in a low energy dense plasma focus device
    Bhuyan, H
    Mohanty, SR
    Neog, NK
    Bujarbarua, S
    Rout, RK
    [J]. JOURNAL OF APPLIED PHYSICS, 2004, 95 (06) : 2975 - 2981
  • [5] QUANTITATIVE X-RAY-EMISSION FROM A DPF DEVICE
    BURKHALTER, PG
    MEHLMAN, G
    NEWMAN, DA
    KRISHNAN, M
    PRASAD, RR
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) : 5052 - 5055
  • [6] FILIPPOV NV, 1962, NUCL FUSION, P577
  • [7] Gautum P., 2015, J FUSION ENERGY
  • [8] Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode
    Gribkov, V. A.
    Bienkowska, B.
    Borowiecki, M.
    Dubrovsky, A. V.
    Ivanova-Stanik, I.
    Karpinski, L.
    Miklaszewski, R. A.
    Paduch, M.
    Scholz, M.
    Tomaszewski, K.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (07) : 1977 - 1989
  • [9] Gribkov V. A., 2000, P SPIE, V4226
  • [10] TRAJECTORIES OF HIGH-ENERGY ELECTRONS IN A PLASMA FOCUS
    HARRIES, WL
    LEE, JH
    MCFARLAND, DR
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1978, 20 (02) : 95 - 106