Purpose: To evaluate whether hepatic magnetic resonance angiography (MRA) performed at 3 T and acquired with a parallel imaging acceleration factor of 2 provides satisfactory image quality and adequate contrast-to-noise, compared with an acquisition without parallel imaging. Materials and Methods: Ton volunteers underwent both a standard (A) and an experimental (B) MRA protocol. Both protocols used a gadoteridol dose of 20 mL injected at 2 mL/s in a 3-T magnetic resonance (MR) system. Protocol B was identical to protocol A, except protocol B was performed with a parallel imaging acceleration factor of 2. Contrast-to-noise ratios (CNRs) were calculated in the suprarenal abdominal aorta, the common hepatic artery, and the right and left hepatic arteries. The same 4 vessels were rated for quality of arterial visualization using a 5-point scale (1 = poor to 5 = excellent). The paired t test and Wilcoxon rank sum test were used for statistical analysis. Results: The CNRs and qualitative scores were higher in all 4 vessels using protocol B. Mean CNRs in the suprarenal abdominal aorta, common hepatic artery, and the right and left hepatic arteries were 31, 33, 28, and 22 for protocol A and 36, 40, 36, and 25 for protocol B, respectively (P < 0.05 except the left hepatic arteries [P = 0.35]). Mean qualitative scores of the same vessels were 4.3, 3.7, 3.1, and 2.9 using protocol A and 4.4, 3.8, 3.5, and 3.2 for protocol B, respectively (P > 0.44). Conclusions: Parallel imaging performed in a 3-T MR system improves hepatic MRA both quantitatively and qualitatively.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 14 条
[1]   Assessment of parallel acquisition techniques in adrenal magnetic resonance imaging: Does increased temporal resolution significantly improve visualization of adrenal lesions? [J].
Boll, DT ;
Hillenbrand, CM ;
Lewin, JS ;
Merkle, EM .
ACADEMIC RADIOLOGY, 2004, 11 (07) :809-816
[2]  
Chen Q, 2004, RADIOLOGY, V231, P893, DOI [10.1148/radiol.2313021113, 10.1148/radio1:2313021113]
[3]  
CURLEY SA, 1993, SURGERY, V114, P928
[4]   Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: Feasibility study [J].
de Vries, M ;
Nijenhuis, RJ ;
Hoogeveen, RM ;
de Haan, MW ;
van Engelshoven, JMA ;
Leiner, T .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) :37-45
[5]   Multi-detector row CT of relevant vascular anatomy of the surgical plane in split-liver transplantation [J].
Guiney, MJ ;
Kruskal, JB ;
Sosna, J ;
Hanto, DW ;
Goldberg, SN ;
Raptopoulos, V .
RADIOLOGY, 2003, 229 (02) :401-407
[6]   Multidetector CT arteriography with volumetric three-dimensional rendering to evaluate patients with metastatic colorectal disease for placement of a floxuridine infusion pump [J].
Kapoor, V ;
Brancatelli, G ;
Federle, MP ;
Katyal, S ;
Marsh, JW ;
Geller, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) :455-463
[7]   Cardiovascular screening with parallel imaging techniques and a whole-body MR imager [J].
Kramer, H ;
Schoenberg, SO ;
Nikolaou, K ;
Huber, A ;
Struwe, A ;
Winnik, E ;
Wintersperger, BJ ;
Dietrich, O ;
Kiefer, B ;
Reiser, MF .
RADIOLOGY, 2005, 236 (01) :300-310
[8]   Utilizing SENSE to achieve lower station sub-millimeter isotropic venous enhancement in resolution and minimal peripheral MR angiography [J].
Maki, JH ;
Wilson, GJ ;
Eubank, WB ;
Hoogeveen, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :484-491
[9]  
Margolis Daniel Jason Aaron, 2004, Top Magn Reson Imaging, V15, P197, DOI 10.1097/01.rmr.0000136557.27727.79
[10]   The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T [J].
Michaely, HJ ;
Nael, K ;
Schoenberg, S ;
Finn, JP ;
Laub, G ;
Reiser, MF ;
Ruehm, SG .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (06) :800-804