Right ventricular function after aortic valve replacement: a pilot study comparing surgical and transcatheter procedures using 3D echocardiography

被引:36
作者
Keyl, Cornelius [1 ]
Schneider, Jens [2 ]
Beyersdorf, Friedhelm [3 ]
Ruile, Philipp [2 ]
Siepe, Matthias [3 ]
Pioch, Katja [1 ]
Schneider, Rebecca [2 ]
Jander, Nikolaus [2 ]
机构
[1] Univ Freiburg, Ctr Heart, Dept Anesthesiol, Suedring 15, D-79189 Bad Krozingen, Germany
[2] Univ Freiburg, Ctr Heart, Dept Cardiol & Angiol 2, D-79189 Bad Krozingen, Germany
[3] Univ Freiburg, Ctr Heart, Dept Cardiovasc Surg, D-79189 Bad Krozingen, Germany
关键词
Right ventricular function; Echocardiography; Aortic stenosis; Aortic valve replacement; Transcatheter aortic valve implantation; TRICUSPID ANNULAR MOTION; RIGHT HEART; SYSTOLIC FUNCTION; CARDIAC-SURGERY; IMPLANTATION; STENOSIS; VOLUME; IMPACT; INDEX; RISK;
D O I
10.1093/ejcts/ezv227
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies have found that standard echocardiographic measures of right ventricular (RV) function were impaired after surgical replacement of the aortic valve (SAVR), but not after transcatheter aortic valve implantation (TAVI). We used 3D echocardiography to gain further insight into the changes of RV performance in patient undergoing SAVR or TAVI. We conducted a prospective non-randomized study with two parallel groups and performed echocardiographic evaluation in 20 patients with aortic stenosis undergoing SAVR (age 77 +/- 4 years), and in 20 patients undergoing TAVI via the transfemoral approach (age 83 +/- 6 years) 1 week before and between the fifth and seventh day after the procedure. Tricuspid annular plane systolic excursion was postoperatively markedly reduced in patients undergoing SAVR (13 +/- 2 vs 26 +/- 4 mm, post- vs preoperative, P < 0.001), but not in patients undergoing TAVI (24 +/- 7 vs 24 +/- 5 mm, P = 0.90). Fractional shortening of the RV midcavity transverse diameter, however, increased after SAVR (50 +/- 8 vs 31 +/- 11%, P < 0.001) in contrast to TAVI (33 +/- 10 vs 34 +/- 9%, P = 0.85). The RV ejection fraction, assessed by 3D echocardiography, remained unchanged in both patient groups (SAVR, 55 +/- 6 vs 55 +/- 7%, P = 0.52; TAVI, 56 +/- 8 vs 54 +/- 7%, P = 0.28). RV longitudinal contraction decreased after SAVR, whereas RV transverse contraction increased. Both parameters did not change after TAVI. RV ejection fraction and RV stroke volume remained constant irrespective of the technique of aortic valve replacement, thus indicating that global systolic RV function is not compromised after SAVR.
引用
收藏
页码:966 / 971
页数:6
相关论文
共 26 条
  • [1] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [2] Differences in Recovery of Left and Right Ventricular Function Following Aortic Valve Interventions: A Longitudinal Echocardiographic Study in Patients Undergoing Surgical, Transapical or Transfemoral Aortic Valve Implantation
    Forsberg, Lena M.
    Tamas, Eva
    Vanky, Farkas
    Engvall, Jan
    Nylander, Eva
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (06) : 1004 - 1014
  • [3] Left and right ventricular function in aortic stenosis patients 8 weeks post-transcatheter aortic valve implantation or surgical aortic valve replacement
    Forsberg, Lena M.
    Tamas, Eva
    Vanky, Farkas
    Nielsen, Niels Erik
    Engvall, Jan
    Nylander, Eva
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (08): : 603 - 611
  • [4] Right ventricular myocardial performance index predicts perioperative mortality or circulatory failure in high-risk valvular surgery
    Haddad, Francois
    Denault, Andre Y.
    Couture, Pierre
    Cartier, Raymond
    Pellerin, Michel
    Levesque, Sylvie
    Lambert, Jean
    Tardif, Jean-Claude
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (09) : 1065 - 1072
  • [5] Decreased right ventricular function after coronary artery bypass grafting and its relation to exercise capacity: A tricuspid annular motion-based study
    Hedman, A
    Alam, M
    Zuber, E
    Nordlander, R
    Samad, BA
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (02) : 126 - +
  • [6] Mechanism of Paradoxical Ventricular Septal Motion After Coronary Artery Bypass Grafting
    Joshi, Subodh B.
    Salah, Ali K.
    Mendoza, Dorinna D.
    Goldstein, Steven A.
    Fuisz, Anthon R.
    Lindsay, Joseph
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (02) : 212 - 215
  • [7] ASSESSMENT OF RIGHT VENTRICULAR-FUNCTION USING TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    KAUL, S
    TEI, C
    HOPKINS, JM
    SHAH, PM
    [J]. AMERICAN HEART JOURNAL, 1984, 107 (03) : 526 - 531
  • [8] Impact of transcatheter aortic valve implantation or surgical aortic valve replacement on right ventricular function
    Kempny, Aleksander
    Diller, Gerhard-Paul
    Kaleschke, Gerrit
    Orwat, Stefan
    Funke, Angela
    Schmidt, Renate
    Kerckhoff, Gregor
    Ghezelbash, Farshad
    Rukosujew, Andreas
    Reinecke, Holger
    Scheld, Hans H.
    Baumgartner, Helmut
    [J]. HEART, 2012, 98 (17) : 1299 - 1304
  • [9] Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI
    Kjaergaard, Jesper
    Petersen, Claus Leth
    Kjaer, Andreas
    Schaadt, Bente Krogsgaard
    Oh, Jae K.
    Hassager, Christian
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (06): : 430 - 438
  • [10] Recommendations for chamber quantification
    Lang, Roberto M.
    Bierig, Michelle
    Devereux, Richard B.
    Flachskampf, Frank A.
    Foster, Elyse
    Pellikka, Patricia A.
    Picard, Michael H.
    Roman, Mary J.
    Seward, James
    Shanewise, Jack
    Solomon, Scott
    Spencer, Kirk T.
    Sutton, Martin St. John
    Stewart, William