Imaging of the lumbar plexus: Optimized refocusing flip angle train design for 3D TSE

被引:17
作者
Cervantes, Barbara [1 ]
Bauer, Jan S. [2 ]
Zibold, Felix [2 ]
Kooijman, Hendrik [3 ]
Settles, Marcus [1 ]
Haase, Axel [4 ]
Rummeny, Ernst J. [1 ]
Woertler, Klaus [1 ]
Karampinos, Dimitrios C. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, Ismaninger Str 22, D-81675 Munich, Germany
[3] Philips Healthcare, Hamburg, Germany
[4] Tech Univ Munich, Zent Inst Med Tech, Garching, Germany
关键词
3D turbo spin echo (TSE); flip angle modulation; magnetic resonance neurography (MRN); extended phase graphs (EPG); magnetic resonance imaging (MRI); lumbar plexus; LONG ECHO TRAINS; MR NEUROGRAPHY; RELAXATION-TIMES; SEQUENCES; NERVE; BRAIN; RARE;
D O I
10.1002/jmri.25076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo study the effects of refocusing angle modulation with 3D turbo spin echo (TSE) on signal and sharpness of small oblique nerves embedded in muscle and suppressed fat in the lumbar plexus. Materials and MethodsFlip angle trains were generated with extended phase graphs (EPG) for a sequence parameter subspace. Signal loss and width broadening were simulated for a single-pixel nerve embedded in muscle and suppressed fat to prescribe a flip angle modulation that gives the best compromise between signal and sharpness of small nerves. Two flip angle trains were defined based on the simulations of small embedded nerves: design denoted A, predicting maximum global signal, and design denoted B, predicting maximum signal for minimum width broadening. In vivo data of the lumbar plexus in 10 healthy volunteers was acquired at 3.0T with 3D TSE employing flip angle trains A and B. Quantitative and qualitative analyses of the acquired data were made to assess changes in width and signal intensity. ResultsChanging flip angle modulation from A to B resulted in: 1) average signal losses of 23% in (larger) L5 nerves and 9% in (smaller) L3 nerves; 2) average width reductions of 4% in L5 nerves and of 16% in L3 nerves; and 3) statistically significant sharpness improvement (P=0.005) in L3 nerves. ConclusionAn optimized flip angle train in 3D TSE imaging of the lumbar plexus considering geometry-specific blurring effects from both the nerve and the surrounding tissue can improve the delineation of small nerves. J. Magn. Reson. Imaging 2016;43:789-799
引用
收藏
页码:789 / 799
页数:11
相关论文
共 31 条
[1]  
[Anonymous], P 19 ANN M ISMRM
[2]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[3]   Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[4]  
Chen W, 2013, P 21 ANN M ISMRM SAL, P3716
[5]   High-Resolution 3T MR Neurography of the Brachial Plexus and Its Branches, with Emphasis on 3D Imaging [J].
Chhabra, A. ;
Thawait, G. K. ;
Soldatos, T. ;
Thakkar, R. S. ;
Del Grande, F. ;
Chalian, M. ;
Carrino, J. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) :486-497
[6]   MR Neurography: Past, Present, and Future [J].
Chhabra, Avneesh ;
Andreisek, Gustav ;
Soldatos, Theodoros ;
Wang, Kenneth C. ;
Flammang, Aaron J. ;
Belzberg, Allan J. ;
Carrino, John A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :583-591
[7]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[8]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[9]   Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla [J].
Ethofer, T ;
Mader, I ;
Seeger, U ;
Helms, G ;
Erb, M ;
Grodd, W ;
Ludolph, A ;
Klose, U .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) :1296-1301
[10]   NMR Properties of Human Median Nerve at 3 T: Proton Density, T1, T2, and Magnetization Transfer [J].
Gambarota, Giulio ;
Mekle, Ralf ;
Mlynarik, Vladimir ;
Krueger, Gunnar .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) :982-986