Use of Cause-and-Effect Analysis to Optimize the Reliability of In Vitro Inhalation Toxicity Measurements Using an Air-Liquid Interface

被引:18
作者
Petersen, Elijah J. [4 ]
Sharma, Monita [1 ]
Clippinger, Amy J. [1 ]
Gordon, John [2 ]
Katz, Aaron [3 ]
Laux, Peter [3 ]
Leibrock, Lars B. [3 ]
Luch, Andreas [3 ]
Matheson, Joanna [2 ]
Stucki, Andreas O. [1 ]
Tentschert, Jutta [3 ]
Bierkandt, Frank S. [3 ]
机构
[1] PETA Sci Consortium Int EV, D-70499 Stuttgart, Germany
[2] US Consumer Prod Safety Commiss, Rockville, MD 20850 USA
[3] German Fed Inst Risk Assessment BfR, Dept Chem & Prod Safety, D-10589 Berlin, Germany
[4] Natl Inst Stand & Technol NIST, Biosyst & Biomat Div, Mat Measurement Lab, Gaithersburg, MD 20899 USA
关键词
EXPOSURE SYSTEM; NANOPARTICLES; CELLS; ASSAY; IDENTIFICATION; MICROPLASTICS; QUALITY; MODEL;
D O I
10.1021/acs.chemrestox.1c00080
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
In vitro inhalation toxicology methods are increasingly being used for research and regulatory purposes. Although the opportunity for increased human relevance of in vitro inhalation methods compared to in vivo tests has been established and discussed, how to systematically account for variability and maximize the reliability of these in vitro methods, especially for assays that use cells cultured at an air-liquid interface (ALI), has received less attention. One tool that has been used to evaluate the robustness of in vitro test methods is cause-and-effect (C&E) analysis, a conceptual approach to analyze key sources of potential variability in a test method. These sources of variability can then be evaluated using robustness testing and potentially incorporated into in-process control measurements in the assay protocol. There are many differences among in vitro inhalation test methods including the use of different types of biological test systems, exposure platforms/conditions, substances tested, and end points, which represent a major challenge for use in regulatory testing. In this manuscript, we describe how C&E analysis can be applied using a modular approach based on the idea that shared components of different test methods (e.g., the same exposure system is used) have similar sources of variability even though other components may differ. C&E analyses of different in vitro inhalation methods revealed a common set of recommended exposure systems and biological in-process control measurements. The approach described here, when applied in conjunction with Good Laboratory Practices (GLP) criteria, should help improve the inter- and intralaboratory agreement of in vitro inhalation test results, leading to increased confidence in these methods for regulatory and research purposes.
引用
收藏
页码:1370 / 1385
页数:16
相关论文
共 86 条
[71]   Assessment of microplastic-sorbed contaminant bioavailability through analysis of biomarker gene expression in larval zebrafish [J].
Sleight, Victoria A. ;
Bakir, Adil ;
Thompson, Richard C. ;
Henry, Theodore B. .
MARINE POLLUTION BULLETIN, 2017, 116 (1-2) :291-297
[72]   Varying solvent type modulates collagen coating and stem cell mechanotransduction on hydrogel substrates [J].
Stanton, Alice E. ;
Tong, Xinming ;
Yang, Fan .
APL BIOENGINEERING, 2019, 3 (03)
[73]   Characterization of the Vitrocell® 24/48 aerosol exposure system for its use in exposures to liquid aerosols [J].
Steiner, Sandro ;
Majeed, Shoaib ;
Kratzer, Gilles ;
Vuillaume, Gregory ;
Hoeng, Julia ;
Frentzel, Stefan .
TOXICOLOGY IN VITRO, 2017, 42 :263-272
[74]   Colloidal properties and stability of aqueous suspensions of few-layer graphene: Importance of graphene concentration [J].
Su, Yu ;
Yang, Guoqing ;
Lu, Kun ;
Petersen, Elijah J. ;
Mao, Liang .
ENVIRONMENTAL POLLUTION, 2017, 220 :469-477
[75]   A standardised approach for the dispersion of titanium dioxide nanoparticles in biological media [J].
Taurozzi, Julian S. ;
Hackley, Vincent A. ;
Wiesner, Mark R. .
NANOTOXICOLOGY, 2013, 7 (04) :389-401
[76]   Comparative iron oxide nanoparticle cellular dosimetry and response in mice by the inhalation and liquid cell culture exposure routes [J].
Teeguarden, Justin G. ;
Mikheev, Vladimir B. ;
Minard, Kevin R. ;
Forsythe, William C. ;
Wang, Wei ;
Sharma, Gaurav ;
Karin, Norman ;
Tilton, Susan C. ;
Waters, Katrina M. ;
Asgharian, Bahman ;
Price, Owen R. ;
Pounds, Joel G. ;
Thrall, Brian D. .
PARTICLE AND FIBRE TOXICOLOGY, 2014, 11
[77]  
The European Parliament and of the Council, 2006, NTR
[78]  
United States Environmental Protection Agency, 2019, DIR PRIOIR EFF RED A
[79]   Fetal Bovine Serum (FBS) - A Pain in the Dish? [J].
van der Valk, Jan ;
Gstraunthaler, Gerhard .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2017, 45 (06) :329-332
[80]   Next-Generation Multifunctional Carbon-Metal Nanohybrids for Energy and Environmental Applications [J].
Wang, Dengjun ;
Saleh, Navid B. ;
Sun, Wenjie ;
Park, Chang Min ;
Shen, Chongyang ;
Aich, Nirupam ;
Peijnenhurg, Willie J. G. M. ;
Zhang, Wei ;
Jin, Yan ;
Su, Chunming .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (13) :7265-7287