Patient radiation dose management in dental facilities according to the X-ray focal distance and the image receptor type

被引:7
作者
Gonzalez, L. [1 ]
Moro, J.
机构
[1] Univ Complutense, Sch Med, Dept Radiol, E-28040 Madrid, Spain
[2] INFOCITEC, Madrid 28039, Spain
关键词
radiation protection; intraoral radiography; patient radiation doses; dose reference values;
D O I
10.1259/dmfr/67494525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To determine particular reference values for patient radiation dose management according to the focus-to-skin distance and the image receptor type. Methods: Air-free ionization chambers and solid state detectors built in quality control devices were used to measure X-ray tube output in a sample of 2811 X-ray units. The mean exposure time was estimated by the local person responsible for the quality assurance programme. From this data, mean air kerma values were calculated at the focus-to-skin distance. To obtain the entrance surface air dose, a backscatter factor of 1.2 was used. Results: Third-quartile values were 5.3 mGy for old X-ray sets with around 10 cm focus-to-skin distance (FSD); for 20 cm FSD, the values were 4.1 mGy for D type, 3.4 mGy for E/F film type and 1.2 mGy for digital image receptors; and for 30 cm FSD the values were 2.1 mGy for D type, 1.8 mGy for E/F film type and 0.6 mGy for digital image receptors. Conclusions: Evidence based on third-quartile values different from those expected justifies the need for particular reference values taking into account image system and focal distance, as a way to improve patient radiation dose management.
引用
收藏
页码:282 / 284
页数:3
相关论文
共 15 条
  • [1] *BOE, 1999, STAT OFF B, P45891
  • [2] CARMICHAEL JHE, 1996, 16260 EUR
  • [3] Effects of developer depletion on image quality of Kodak Insight and Ektaspeed Plus films
    Casanova, MLS
    Haiter-Neto, F
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (02) : 108 - 113
  • [4] *EUR COMM, 2004, RAD PROT EUR COMM, V136
  • [5] European Commission, 1999, RAD PROT EUR COMM
  • [6] Evaluation of a new F speed dental X-ray film. The effect of processing solutions and a comparison with D and E speed films
    Farman, TT
    Farman, AG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) : 41 - 45
  • [7] Reference doses in dental radiodiagnostic facilities
    González, L
    Vañó, E
    Fernández, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (878) : 153 - 156
  • [8] *INT AT EN AG, 1996, SAF SER IAEA, V115
  • [9] Johns H. E., 1983, PHYS RADIOLOGY
  • [10] Reference doses for dental radiography
    Napier, ID
    [J]. BRITISH DENTAL JOURNAL, 1999, 186 (08) : 392 - 396