Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants

被引:35
作者
Acil, Yahya [1 ]
Sievers, Jan [2 ]
Guelses, Aydin [3 ]
Ayna, Mustafa [4 ]
Wiltfang, Joerg [1 ]
Terheyden, Hendrik [5 ]
机构
[1] Christian Albrecht Univ Kiel, Dept Oral & Maxillofacial Surg, Kiel, Germany
[2] Zahnarztliche Gemeinschaftspraxis Dres Isabelle &, Waiblingen, Germany
[3] Gulhane Mil Med Acad, Ctr Dent Sci, TR-06010 Ankara, Turkey
[4] Ctr Implantol, Private Practice, Duisburg, Germany
[5] Rotes Kreuz Krankenhaus Kassel, Clin Oral & Maxillofacial Surg, Kassel, Germany
关键词
Bone-implant contact; Resonance frequency analysis; Insertion torque; Primary stability; Correlation; Immediate loading; Dental implants; Histomorphometric measurements; STABILITY QUOTIENT; DENTAL IMPLANTS; TITANIUM IMPLANTS; VALUES; OSSEOINTEGRATION; COMPRESSION; BLADES; IMPACT;
D O I
10.1007/s10266-016-0265-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the correlation between resonance frequency analysis (RFA) values and the histomorphometric bone-implant contact (BIC) immediately after insertion of the implant. Additionally, it was examined to define which extent peak insertion torque (PIT) was correlated with the latter measurements. 15 Xive(A (R)) S plus root from dental implants were inserted in fresh porcine frontal bones. The insertion torque was measured with the Kavo Intrasurg 300 surgical unit. RFA connector was coupled to the implants and the mean value of 20 consecutive RFA measurements was calculated via Osstell(A (R)) ISQ device. The implants were removed with the adjacent bone with a band saw. The blocks were processed for undecalcified histology. Two perpendicular longitudinal middle sections of the implant were made and stained with toluidine blue and the BIC was assessed by histomorphometry. The correlation coefficient (Spearman) between RFA and BIC was R = 0.579 (p = 0.026, F test). The correlation between PIT and BIC (0.33, p > 0.05) and PIT and RFA (0.153, p > 0.05) was not statistically significant. The present data confirmed a moderate and statistically positive correlation between RFA and BIC. No correlation between BIC and PIT and PIT and RFA was observed. Further studies considering different bone qualities would be beneficial in understanding the relation between RFA and BIC.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 31 条
[1]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[2]   Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro [J].
Akca, K. ;
Kokat, A. M. ;
Comert, A. ;
Akkocaoglu, M. ;
Tekdemir, I. ;
Cehreli, M. C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (02) :169-173
[3]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[4]   Tierexperimentelle Evaluation des periimplantären Knochens bei zylindrischen gegenüber konischen ImplantattypenPeri-implant bone formation around cylindrical and conical implant systems [J].
A. Büchter ;
J. Kleinheinz ;
H.-P. Wiesmann ;
L. Seper ;
U. Joos ;
U. Meyer .
Mund-, Kiefer- und Gesichtschirurgie, 2004, 8 (5) :282-288
[5]  
Buser D, 1998, INT J ORAL MAX IMPL, V13, P611
[6]   Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets [J].
Cehreli, Murat Cavit ;
Kokat, Ali Murat ;
Comert, Ayhan ;
Akkocaoglu, Murat ;
Tekdemir, Ibrahim ;
Akca, Kwanc .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) :1163-1169
[7]  
Chowdary R., 2014, CLIN ORAL IMPLAN S10, V25, P1
[8]   Resonance Frequency Analysis, Insertion Torque, and Bone to Implant Contact of 4 Implant Surfaces: Comparison and Correlation Study in Sheep [J].
Dagher, Maroun ;
Mokbel, Nadim ;
Jabbour, Gabriel ;
Naaman, Nada .
IMPLANT DENTISTRY, 2014, 23 (06) :672-678
[9]   Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants [J].
Degidi, Marco ;
Perrotti, Vittoria ;
Strocchi, Rita ;
Piattelli, Adriano ;
Iezzi, Giovanna .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (08) :778-781
[10]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326