Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination

被引:38
作者
Kurz, Thomas [1 ,2 ,3 ]
Couperus, Jurjen Pieter [1 ,3 ]
Kraemer, Jakob Matthias [1 ,3 ]
Ding, Hao [2 ,4 ]
Kuschel, Stephan [5 ,6 ]
Koehler, Alexander [1 ,3 ]
Zarini, Omid [1 ,3 ]
Hollatz, Dominik [5 ,6 ]
Schinkel, David [5 ,6 ]
D'Arcy, Richard [7 ]
Schwinkendorf, Jan-Patrick [7 ,8 ]
Osterhoff, Jens [7 ]
Irman, Arie [1 ]
Schramm, Ulrich [1 ,3 ]
Karsch, Stefan [2 ,4 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Bautzner Landstr 400, D-01328 Dresden, Germany
[2] Ludwig Maximilians Univ Munchen, Coulombwall 1, D-85748 Garching, Germany
[3] Tech Univ Dresden, D-01069 Dresden, Germany
[4] Max Planck Inst Quantum Opt, Hans Kopfermann Str 1, D-85748 Garching, Germany
[5] Helmholtz Inst Jena, Frobelstieg 3, D-07743 Jena, Germany
[6] Friedrich Schiller Univ Jena, Furstengraben 1, D-07743 Jena, Germany
[7] DESY, Notkestr 85, D-22607 Hamburg, Germany
[8] Univ Hamburg, Inst Expt Phys, D-22761 Hamburg, Germany
基金
欧盟地平线“2020”;
关键词
LASER-PLASMA ACCELERATOR; X-RAYS; BEAMS; LIGHT;
D O I
10.1063/1.5041755
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm(2 )were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm(2). The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm(2) indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 1964, THEORY PRACTICE SCIN
[2]   Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV [J].
Bonnet, T. ;
Comet, M. ;
Denis-Petit, D. ;
Gobet, F. ;
Hannachi, F. ;
Tarisien, M. ;
Versteegen, M. ;
Aleonard, M. M. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (01)
[3]   Absolute charge calibration of scintillating screens for relativistic electron detection [J].
Buck, A. ;
Zeil, K. ;
Popp, A. ;
Schmid, K. ;
Jochmann, A. ;
Kraft, S. D. ;
Hidding, B. ;
Kudyakov, T. ;
Sears, C. M. S. ;
Veisz, L. ;
Karsch, S. ;
Pawelke, J. ;
Sauerbrey, R. ;
Cowan, T. ;
Krausz, F. ;
Schramm, U. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (03)
[4]   Demonstration of a beam loaded nanocoulombclass laser wakefield accelerator [J].
Couperus, J. P. ;
Pausch, R. ;
Koehler, A. ;
Zarini, O. ;
Kraemer, J. M. ;
Garten, M. ;
Huebl, A. ;
Gebhardt, R. ;
Helbig, U. ;
Bock, S. ;
Zeil, K. ;
Debus, A. ;
Bussmann, M. ;
Schramm, U. ;
Irman, A. .
NATURE COMMUNICATIONS, 2017, 8
[5]   Diagnostics for plasma-based electron accelerators [J].
Downer, M. C. ;
Zgadzaj, R. ;
Debus, A. ;
Schramm, U. ;
Kaluza, M. C. .
REVIEWS OF MODERN PHYSICS, 2018, 90 (03)
[6]   Physics of laser-driven plasma-based electron accelerators [J].
Esarey, E. ;
Schroeder, C. B. ;
Leemans, W. P. .
REVIEWS OF MODERN PHYSICS, 2009, 81 (03) :1229-1285
[7]   A laser-plasma accelerator producing monoenergetic electron beams [J].
Faure, J ;
Glinec, Y ;
Pukhov, A ;
Kiselev, S ;
Gordienko, S ;
Lefebvre, E ;
Rousseau, JP ;
Burgy, F ;
Malka, V .
NATURE, 2004, 431 (7008) :541-544
[8]   Demonstration of a 1.1 petawatt laser based on a hybrid optical parametric chirped pulse amplification/mixed Nd:glass amplifier [J].
Gaul, Erhard W. ;
Martinez, Mikael ;
Blakeney, Joel ;
Jochmann, Axel ;
Ringuette, Martin ;
Hammond, Doug ;
Borger, Ted ;
Escamilla, Ramiro ;
Douglas, Skylar ;
Henderson, Watson ;
Dyer, Gilliss ;
Erlandson, Alvin ;
Cross, Rick ;
Caird, John ;
Ebbers, Christopher ;
Ditmire, Todd .
APPLIED OPTICS, 2010, 49 (09) :1676-1681
[9]   High-quality electron beams from a laser wakefield accelerator using plasma-channel guiding [J].
Geddes, CGR ;
Toth, C ;
van Tilborg, J ;
Esarey, E ;
Schroeder, CB ;
Bruhwiler, D ;
Nieter, C ;
Cary, J ;
Leemans, WP .
NATURE, 2004, 431 (7008) :538-541
[10]   LIGHT ANGULAR-DISTRIBUTION OF FLUORESCENT SCREENS EXCITED BY X-RAYS [J].
GIAKOUMAKIS, GE ;
MILIOTIS, DM .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (01) :21-29