Bayesian algorithms for PET image reconstruction with mean curvature and Gauss curvature diffusion regularizations

被引:19
作者
Zhu, Hongqing [1 ]
Shu, Huazhong [1 ]
Zhou, Jian [1 ]
Bao, Xudong [1 ]
Luo, Limin [1 ]
机构
[1] SE Univ, Dept Comp Sci & Engn, Lab Image Sci & Technol, Dept Comp Sci & Engn, Nanjing 210096, Peoples R China
关键词
positron emission tomography (PET); total variation; mean curvature; Gauss curvature; iterative Bayesian reconstruction; regularization;
D O I
10.1016/j.compbiomed.2006.08.015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The basic mathematical problem behind PET is an inverse problem. Due to the inherent ill-posedness of this inverse problem, the reconstructed images will have noise and edge artifacts. A roughness penalty is often imposed on the solution to control noise and stabilize the solution, but the difficulty is to avoid the smoothing of edges. In this paper, we propose two new types of Bayesian one-step-late reconstruction approaches which utilize two different prior regularizations: the mean curvature (MC) diffusion function and the Gauss curvature (GC) diffusion function. As they have been studied in image processing for removing noise, these two prior regularizations encourage preserving the edge while the reconstructed images are smoothed. Moreover, the GC constraint can preserve smaller structures which cannot be preserved by MC. The simulation results show that the proposed algorithms outperform the quadratic function and total variation approaches in terms of preserving the edges during emission reconstruction. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:793 / 804
页数:12
相关论文
共 28 条
[1]   ANALYSIS OF BOUNDED VARIATION PENALTY METHODS FOR ILL-POSED PROBLEMS [J].
ACAR, R ;
VOGEL, CR .
INVERSE PROBLEMS, 1994, 10 (06) :1217-1229
[2]   Motion of hypersurfaces by Gauss curvature [J].
Andrews, B .
PACIFIC JOURNAL OF MATHEMATICS, 2000, 195 (01) :1-34
[3]   A well-balanced flow equation for noise removal and edge detection [J].
Barcelos, CAZ ;
Boaventura, M ;
Silva, EC .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2003, 12 (07) :751-763
[4]  
BOUMAN C, 1993, IEEE T MED IMAGING, V12, P293
[5]   Regularized image reconstruction algorithms for positron emission tomography [J].
Chang, JH ;
Anderson, JMM ;
Votaw, JR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) :1165-1175
[6]   Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior [J].
Chlewicki, W ;
Hermansen, F ;
Hansen, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (20) :4717-4730
[7]   Anisotropic diffusion filtering of PET attenuation data to improve emission images [J].
Demirkaya, O .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (20) :N271-N278
[8]   A maximum a posteriori reconstruction method for plasma tomography [J].
Denisova, N .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2004, 13 (03) :531-536
[9]   Bayesian reconstruction in SPECT with entropy prior and iterative statistical regularization [J].
Denisova, NV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) :136-141
[10]   Mean curvature evolution and surface area scaling in image filtering [J].
ElFallah, AI ;
Ford, GE .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1997, 6 (05) :750-753