A Robust and Reliable Test to Measure Stereopsis in the Clinic

被引:25
作者
Hess, Robert F. [1 ]
Ding, Rifeng [1 ]
Clavagnier, Simon [1 ]
Liu, Catherine [1 ]
Guo, Cindy [2 ]
Viner, Catherine [3 ]
Barrett, Brendan T. [3 ]
Radia, Krupali [3 ]
Zhou, Jiawei [1 ]
机构
[1] McGill Univ, Dept Ophthalmol, McGill Vis Res, Montreal, PQ H3A 2T5, Canada
[2] Univ Auckland, Dept Vis Sci & Optometry, Auckland 1, New Zealand
[3] Univ Bradford, Sch Optometry & Vis Sci, Bradford BD7 1DP, W Yorkshire, England
基金
加拿大自然科学与工程研究理事会;
关键词
clinic; stereoacuity; iPod; BINOCULAR IPAD TREATMENT; AMBLYOPIA; STEREOACUITY; SENSITIVITY; ADULTS;
D O I
10.1167/iovs.15-18690
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to develop a convenient test of stereopsis in the clinic that is both robust and reliable and capable of providing a measure of variability necessary to make valid comparisons between measurements obtained at different occasions or under different conditions. METHODS. Stereo acuity was measured based on principles derived from the laboratory measurement of stereopsis (i.e., staircase method). Potential premeasurement compensations are described if there is a significant degree of ocular misalignment, reduced visual acuity, or aniseikonia. Forty-six adults at McGill University, 44 adults at Auckland University, and 51 adults from the University of Bradford, with an age range of 20 to 65 years old and normal or corrected-to-normal vision participated in this study. RESULTS. Stereo acuity within this normal population was widely distributed, with a significant percentage (28%) of the population with only coarse stereo (>300 arc seconds). Across subjects, the SD was approximately 25% of the mean. Measurements at two different times were strongly (r = 0.79) and significantly (P < 0.001) correlated, with little to no significant (P = 0.79) bias (0.01) between test and retest measures of stereopsis. CONCLUSIONS. The application enables measurements over the wide disparity range and not just at the finest disparities. In addition, it allows changes in stereopsis of the order of 1.9 to be statistically distinguished.
引用
收藏
页码:798 / 804
页数:7
相关论文
共 50 条
  • [41] The Healthy Eating Index-2010 Is a Valid and Reliable Measure of Diet Quality According to the 2010 Dietary Guidelines for Americans
    Guenther, Patricia M.
    Kirkpatrick, Sharon I.
    Reedy, Jill
    Krebs-Smith, Susan M.
    Buckman, Dennis W.
    Dodd, Kevin W.
    Casavale, Kellie O.
    Carroll, Raymond J.
    JOURNAL OF NUTRITION, 2014, 144 (03) : 399 - 407
  • [42] Concurrent Criterion-Related Validity and Reliability of a Clinical Test to Measure Femoral Anteversion
    Souza, Richard B.
    Powers, Christopher M.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2009, 39 (08) : 586 - 592
  • [43] The use of the mannitol test as an outcome measure in asthma intervention studies: a review and practical recommendations
    Sverrild, Asger
    Leadbetter, Joanna
    Porsbjerg, Celeste
    RESPIRATORY RESEARCH, 2021, 22 (01)
  • [44] A simple and robust method for multivariate meta-analysis of diagnostic test accuracy
    Chen, Yong
    Liu, Yulun
    Chu, Haitao
    Lee, Mei-Ling Ting
    Schmid, Christopher H.
    STATISTICS IN MEDICINE, 2017, 36 (01) : 105 - 121
  • [45] Does the Finger-to-Nose Test measure upper limb coordination in chronic stroke?
    Rodrigues, Marcos R. M.
    Slimovitch, Matthew
    Chilingaryan, Gevorg
    Levin, Mindy F.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14 : 1 - 11
  • [46] False-Positive Rates of Reliable Change Indices for Concussion Test Batteries: A Monte Carlo Simulation
    Nelson, Lindsay D.
    JOURNAL OF ATHLETIC TRAINING, 2015, 50 (12) : 1319 - 1322
  • [47] How many blinks are necessary for a reliable startle response? A test using the NPU-threat task
    Lieberman, Lynne
    Stevens, Elizabeth S.
    Funkhouser, Carter J.
    Weinberg, Anna
    Sarapas, Casey
    Huggins, Ashley A.
    Shankman, Stewart A.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2017, 114 : 24 - 30
  • [48] Electric toothbrush application is a reliable and valid test for differentiating temporomandibular disorders pain patients from controls
    Nixdorf, Donald R.
    Hemmaty, Azar
    Look, John O.
    Schiffman, Eric L.
    John, Mike T.
    BMC MUSCULOSKELETAL DISORDERS, 2009, 10
  • [49] Developing a Valid and Reliable Cross-cultural Measure of Coparenting Conflict between Divorced Parents: The Portuguese Version of the Acrimony Scale
    Peixoto, Judite M. A.
    Goncalves, Mariana A., V
    Gaspar, Maria Filomena
    Matos, Marlene A., V
    JOURNAL OF CHILD AND FAMILY STUDIES, 2022, 31 (06) : 1664 - 1682
  • [50] The Short Health Scale: A valid and reliable measure of health related quality of life in English speaking inflammatory bowel disease patients
    McDermott, Edel
    Keegan, Denise
    Byrne, Kathryn
    Doherty, Glen A.
    Mulcahy, Hugh E.
    JOURNAL OF CROHNS & COLITIS, 2013, 7 (08) : 616 - 621