A Robust and Reliable Test to Measure Stereopsis in the Clinic

被引:25
|
作者
Hess, Robert F. [1 ]
Ding, Rifeng [1 ]
Clavagnier, Simon [1 ]
Liu, Catherine [1 ]
Guo, Cindy [2 ]
Viner, Catherine [3 ]
Barrett, Brendan T. [3 ]
Radia, Krupali [3 ]
Zhou, Jiawei [1 ]
机构
[1] McGill Univ, Dept Ophthalmol, McGill Vis Res, Montreal, PQ H3A 2T5, Canada
[2] Univ Auckland, Dept Vis Sci & Optometry, Auckland 1, New Zealand
[3] Univ Bradford, Sch Optometry & Vis Sci, Bradford BD7 1DP, W Yorkshire, England
基金
加拿大自然科学与工程研究理事会;
关键词
clinic; stereoacuity; iPod; BINOCULAR IPAD TREATMENT; AMBLYOPIA; STEREOACUITY; SENSITIVITY; ADULTS;
D O I
10.1167/iovs.15-18690
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to develop a convenient test of stereopsis in the clinic that is both robust and reliable and capable of providing a measure of variability necessary to make valid comparisons between measurements obtained at different occasions or under different conditions. METHODS. Stereo acuity was measured based on principles derived from the laboratory measurement of stereopsis (i.e., staircase method). Potential premeasurement compensations are described if there is a significant degree of ocular misalignment, reduced visual acuity, or aniseikonia. Forty-six adults at McGill University, 44 adults at Auckland University, and 51 adults from the University of Bradford, with an age range of 20 to 65 years old and normal or corrected-to-normal vision participated in this study. RESULTS. Stereo acuity within this normal population was widely distributed, with a significant percentage (28%) of the population with only coarse stereo (>300 arc seconds). Across subjects, the SD was approximately 25% of the mean. Measurements at two different times were strongly (r = 0.79) and significantly (P < 0.001) correlated, with little to no significant (P = 0.79) bias (0.01) between test and retest measures of stereopsis. CONCLUSIONS. The application enables measurements over the wide disparity range and not just at the finest disparities. In addition, it allows changes in stereopsis of the order of 1.9 to be statistically distinguished.
引用
收藏
页码:798 / 804
页数:7
相关论文
共 50 条
  • [21] Fructosamine is Not a Reliable Test for the Detection of Hyperglycemia: Insight from the Africans in America Study
    Gatete, Jean de Dieu
    Worthy, Charlita C.
    Jagannathan, Ram
    Dubose, Christopher W.
    Sacks, David B.
    Sumner, Anne E.
    DIABETES METABOLIC SYNDROME AND OBESITY, 2023, 16 : 2689 - 2693
  • [22] Is microscopic agglutination test a reliable method for diagnosing the bovine genital leptospirosis syndrome?
    Aymee, Luiza
    Borges, Ana Luiza Dos Santos Baptista
    de Souza, Guilherme Nunes
    Lilenbaum, Walter
    VETERINARY RESEARCH COMMUNICATIONS, 2024, 48 (06) : 4185 - 4189
  • [23] Reconsidering the Word Memory Test as a Memory Measure in Traumatic Brain Injury
    Davis, Jeremy J.
    ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2016, 31 (07) : 802 - 810
  • [24] Presentation and eustachian tube function test results in children evaluated at a specialty clinic
    Alper, Cuneyt M.
    Teixeira, Miriam S.
    Richert, Beverly C.
    Swarts, J. Douglas
    LARYNGOSCOPE, 2019, 129 (05) : 1218 - 1228
  • [25] Development of the Friendships and Social Skills Test (FASST): A Parent Report Measure
    Whiteside, Stephen P. H.
    McCarthy, Denis M.
    Sim, Leslie A.
    Biggs, Bridget K.
    Petrikin, Joshua E.
    Mellon, Michael W.
    JOURNAL OF CHILD AND FAMILY STUDIES, 2016, 25 (06) : 1777 - 1788
  • [26] Reliability and validity of a new measure of agility and equilibrium: the reaction balance test
    Oyama, Yusuke
    Murayama, Toshio
    HUMAN MOVEMENT, 2023, 24 (01) : 140 - 148
  • [27] Reading the mind in infant eyes test: A measure of the recognition of infant emotion
    Barnett, Whitney
    Garon-Bissonnette, Julia
    Carrow, Casey
    Piersiak, Hannah A.
    Bailes, Lauren G.
    Ledgister, Jada
    Humphreys, Kathryn L.
    DEVELOPMENT AND PSYCHOPATHOLOGY, 2025,
  • [28] Psychometric properties of Clock Drawing Test and MMSE or Short Performance Test (SKT) in dementia screening in a memory clinic population
    Schramm, U
    Berger, G
    Müller, R
    Kratzsch, T
    Peters, J
    Frölich, L
    INTERNATIONAL JOURNAL OF GERIATRIC PSYCHIATRY, 2002, 17 (03) : 254 - 260
  • [29] The Relative Atrial Index (RAI)-A Novel, Simple, Reliable, and Robust Transthoracic Echocardiographic Indicator of Atrial Defects
    Kelly, Natalie F. A.
    Walters, Darren L.
    Hourigan, Lisa A.
    Burstow, Darryl J.
    Scalia, Gregory M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (03) : 275 - 281
  • [30] Robust Multi-objective H∞ Reliable Control for Delta Operator Switched Uncertain Linear Systems
    Hu, Hao
    Jiang, Bin
    Yang, Hao
    Alexey, Shumsky
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2015, 13 (03) : 662 - 671