Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants

被引:76
作者
Chang, Po-Chun [3 ,4 ,5 ]
Lang, Niklaus P. [2 ]
Giannobile, William V. [1 ,4 ,5 ]
机构
[1] Univ Michigan, Sch Dent, Michigan Ctr Oral Hlth Res, Ann Arbor, MI 48109 USA
[2] Univ Hong Kong, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[3] Natl Univ Singapore, Fac Dent, Div Periodontol, Dept Prevent Dent, Singapore 117548, Singapore
[4] Univ Michigan, Coll Engn, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[5] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
bone-implant interactions; finite element analysis; growth factor; BONE MORPHOGENETIC PROTEIN-2; GROWTH-FACTOR-I; RESONANCE FREQUENCY MEASUREMENTS; HYDROXYAPATITE-COATED IMPLANTS; 3-DIMENSIONAL FINITE-ELEMENT; TITANIUM DENTAL IMPLANTS; OSTEOBLAST DIFFERENTIATION; SURFACE CHARACTERISTICS; ENDOSSEOUS IMPLANTS; TRABECULAR BONE;
D O I
10.1111/j.1600-0501.2009.01826.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this paper is to review current investigations on functional assessments of osseointegration and assess correlations to the peri-implant structure. Material and methods The literature was electronically searched for studies of promoting dental implant osseointegration, functional assessments of implant stability, and finite element (FE) analyses in the field of implant dentistry, and any references regarding biological events during osseointegration were also cited as background information. Results Osseointegration involves a cascade of protein and cell apposition, vascular invasion, de novo bone formation and maturation to achieve the primary and secondary dental implant stability. This process may be accelerated by alteration of the implant surface roughness, developing a biomimetric interface, or local delivery of growth-promoting factors. The current available pre-clinical and clinical biomechanical assessments demonstrated a variety of correlations to the peri-implant structural parameters, and functionally integrated peri-implant structure through FE optimization can offer strong correlation to the interfacial biomechanics. Conclusions The progression of osseointegration may be accelerated by alteration of the implant interface as well as growth factor applications, and functional integration of peri-implant structure may be feasible to predict the implant function during osseointegration. More research in this field is still needed. To cite this article:Chang P-C, Lang NP, Giannobile WV. Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.Clin. Oral Impl. Res. 21, 2010; 1-12.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 148 条