Compression-free biplanar radiography of the breast specimen with a specimen device

被引:5
作者
Grunert, JH
Wiechmann, U
Gmelin, E
机构
[1] Oststadtkrankenhaus Hannover, Med Hsch Hannover, D-31303 Burgdorf, Germany
[2] Hannover Med Sch, Forschungswerkstatten, Hannover, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 03期
关键词
breast cancer; microcalcification; specimen device; specimen radiography;
D O I
10.1055/s-2003-37821
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a device for specimen radiography of impalpable breast lesions with microcalcifications in order to perform compression-free radiography in two planes and to document the original orientation of the specimen on the radiographic film. Materials and Methods: A curved plate with its radius equal to the film-focus-distance enables specimen radiography without compression and with minimizing artifacts induced by beam divergency. Adjustable markers can document the topographic orientation of the specimen on the radiographic film. Results: The presented specimen device for biplanar radiography avoids interfering compression artifacts for both radiologist and pathologist. Documenting the original topographic orientation of the specimen on the film helps to guide the surgeon in cases requiring further resection. Discussion: Biplanar specimen radiography without compression of the specimen measures the distance of microcalcifications to the margin of the resected tissue more accurately and thus provides a better basis for planning any necessary additional resection.
引用
收藏
页码:413 / 417
页数:5
相关论文
共 12 条
  • [2] A PERSPEX GRID FOR LOCALIZATION OF NON-PALPABLE MAMMOGRAPHIC LESIONS IN BREAST BIOPSIES
    CHAMP, CS
    MASON, CH
    COGHILL, SB
    ROBINSON, M
    [J]. HISTOPATHOLOGY, 1989, 14 (03) : 311 - 315
  • [3] BREAST SPECIMEN RADIOGRAPHY - EVALUATION OF A COMPRESSION DEVICE
    CHILCOTE, WA
    DAVIS, GA
    SUCHY, P
    PAUSHTER, DM
    [J]. RADIOLOGY, 1988, 168 (02) : 425 - 427
  • [4] Intraoperative digital radiography for diagnosis of non-palpable breast lesions
    Diekmann, F
    Grebe, S
    Bick, U
    Winzer, KJ
    Paepke, S
    Hamm, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 969 - 971
  • [5] Magnified radiographs as quality control for detection of microcalcifications in histopathology of breast biopsies
    Grunert, JH
    Flemming, P
    Borchert, B
    Farber, A
    Gmelin, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01): : 68 - 72
  • [6] Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography.
    Grunert, JH
    Borchert, B
    Farber, A
    Gmelin, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (04): : 302 - 306
  • [7] Grunert JH, 1999, ROFO-FORTSCHR RONTG, V170, P347
  • [8] A comparison of conventional mammographic magnification, ultra high magnification and industrial magnification radiography in the radiographic detection of microcalcifications within core biopsies of the breast
    Moritz, JD
    LuftnerNagel, S
    Westerhof, JP
    Oestmann, JW
    Grabbe, E
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (839) : 1099 - 1103
  • [9] A new specimen radiography system with maximal 20fold magnification for breast specimens
    Moritz, JD
    Westerhof, JP
    Funke, M
    Breiter, N
    Oestmann, JW
    Grabbe, E
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (02): : 133 - 138
  • [10] Microcalcifications in breast core biopsy specimens: Disappearance at radiography after storage in formaldehyde
    Moritz, JD
    LuftnerNagel, S
    Westerhof, JP
    Oestmann, JW
    Grabbe, E
    [J]. RADIOLOGY, 1996, 200 (02) : 361 - 363