Diseased red blood cells studied by atomic force microscopy

被引:8
作者
Chen, Yong [1 ]
Cai, Jiye [1 ]
Zhao, Jingxian [1 ]
机构
[1] Jinan Univ, Dept Chem, Guangzhou 510632, Guangdong, Peoples R China
来源
International Journal of Nanoscience, Vol 1, Nos 5 and 6 | 2002年 / 1卷 / 5-6期
关键词
diseased red blood cells; atomic force microscopy; lung cancer; myelodisplastic syndrome; echinocytes; projections;
D O I
10.1142/S0219581X02000899
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In recent years, many mammalian cells, especially erythrocytes because of simpleness of their membrane surfaces, were widely studied by atomic force microscopy. In our study, diseased erythrocytes were taken from patients of lung cancer, myelodisplastic syndrome (MDS), and so on. We obtained many clear topographical images of numerous erythrocytes, single erythrocyte, and ultramicrostructure of erythrocyte membrane surfaces from normal persons and patients. By studying the red cells of lung cancer patients, we found that many erythrocytes of lung cancer patient have changed into echinocytes. One erythrocyte has 10-20 short projections, most of which, with a mean width of 589.0 mn and a length of 646.7 nm, are on the edge of cell. The projections in the center of echinocytes are lodged and embedded, but in conventional model of echinocytes, the projections in the center stretch outside cell membrane, so a novel model of erythrocytes was designed in our paper. After observation of microstructure of MDS patient's erythrocyte membrane surface, we found that many apertures with different diameters of tens to hundreds nanometers appeared on the surface of cell membrane. It can be concluded that AFM may be widely applied in clinic pathological inspection.
引用
收藏
页码:683 / 688
页数:6
相关论文
共 18 条
[1]   Is echinocytic transformation of erythrocytes related to lipid peroxidation in hemodialysed uraemic patients? [J].
Agroyannis, B ;
Tzanatos, H ;
Fourtounas, C ;
Soubassi, L ;
Kopelias, I ;
Koutsikos, D .
CLINICA CHIMICA ACTA, 1997, 261 (02) :185-187
[2]  
Aikawa Masamichi, 1997, Parasitology International, V46, P241, DOI 10.1016/S1383-5769(97)00031-7
[3]   Gadolinium induces domain and pore formation of human erythrocyte membrane: an atomic force microscopic study [J].
Cheng, Y ;
Liu, MZ ;
Li, RC ;
Wang, C ;
Bai, CL ;
Wang, K .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1999, 1421 (02) :249-260
[4]   The study of protein mechanics with the atomic force microscope [J].
Fisher, TE ;
Oberhauser, AF ;
Carrion-Vazquez, M ;
Marszalek, PE ;
Fernandez, JM .
TRENDS IN BIOCHEMICAL SCIENCES, 1999, 24 (10) :379-384
[5]   Artificially induced unusual shape of erythrocytes: an atomic force microscopy study [J].
Girasole, M ;
Cricenti, A ;
Generosi, R ;
Congiu-Castellano, A ;
Boumis, G ;
Amiconi, G .
JOURNAL OF MICROSCOPY-OXFORD, 2001, 204 (01) :46-52
[6]   Affinity imaging of red blood cells using an atomic force microscope [J].
Grandbois, M ;
Dettmann, W ;
Benoit, M ;
Gaub, HE .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2000, 48 (05) :719-724
[7]   Elasticity mapping of living fibroblasts by AFM and immunofluorescence observation of the cytoskeleton [J].
Haga, H ;
Sasaki, S ;
Kawabata, K ;
Ito, E ;
Ushiki, T ;
Sambongi, T .
ULTRAMICROSCOPY, 2000, 82 (1-4) :253-258
[8]   A possible mechanism determining the stability of spiculated red blood cells [J].
Iglic, A .
JOURNAL OF BIOMECHANICS, 1997, 30 (01) :35-40
[9]   Adapting atomic force microscopy for cell biology [J].
Lehenkari, PP ;
Charras, GT ;
Nykänen, A ;
Horton, MA .
ULTRAMICROSCOPY, 2000, 82 (1-4) :289-295
[10]   The cell biological application of carbon nanotube probes for atomic force microscopy: comparative studies of malaria-infected erythrocytes [J].
Nagao, E ;
Nishijima, H ;
Akita, S ;
Nakayama, Y ;
Dvorak, JA .
JOURNAL OF ELECTRON MICROSCOPY, 2000, 49 (03) :453-458