A novel integrable microvalve for refreshable Braille display system

被引:60
作者
Yobas, L
Durand, DM
Skebe, GG
Lisy, FJ
Huff, MA
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Orbital Res Inc, Cleveland, OH 44143 USA
[3] MEMS Exchange Corp Natl Res Initiat, Reston, VA 20191 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Braille; electrostatic; fluid-solid mechanics; microvalve; modeling; tactile display;
D O I
10.1109/JMEMS.2003.811754
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We introduce a novel integrable and electrostatic microvalve for the purpose of enabling a pneumatic refreshable Braille display system (RBDS). Physical design parameters of the microvalve such as orifice size, beam length, number of beams and beam profile are experimentally explored and found promising for use with the RBDS. Particularly, one design with an orifice of 70 mum x 70 mum, beam length 665 mum, and beam count 20 is electrostatically closed against a differential pressure of 82.7 kPa with an applied voltage of 68 V-rms. Also introduced is a steady-state mechanical model of the microvalve established on coupled solution of fluid and solid domains. The model and experimental test results have been used to calculate the unknown discharge coefficient, elastic deflection, and entrance pressure. The model revealed some of the designs have remarkably low discharge coefficient and entrance pressure, implying that pressure loss occurs mostly through and around the inlet port even at fairly large supply pressures. The experimental observations concerning the practical use of the microvalve are discussed.
引用
收藏
页码:252 / 263
页数:12
相关论文
共 35 条
[1]   VISION SUBSTITUTION BY TACTILE IMAGE PROJECTION [J].
BACH, P ;
COLLINS, CC ;
SAUNDERS, FA ;
WHITE, B ;
SCADDEN, L .
NATURE, 1969, 221 (5184) :963-&
[2]  
Bliss J. C., 1970, IEEE Transactions on Man-Machine Systems, Vmms-11, P101, DOI 10.1109/TMMS.1970.299969
[3]   OPTICAL-TO-TACTILE IMAGE CONVERSION FOR BLIND [J].
BLISS, JC ;
KATCHER, MH ;
ROGERS, CH ;
SHEPARD, RP .
IEEE TRANSACTIONS ON MAN-MACHINE SYSTEMS, 1970, MM11 (01) :58-&
[4]  
Brei D. E., 1992, Journal of Microelectromechanical Systems, V1, P106, DOI 10.1109/84.186389
[5]   Factors enhancing the reliability of touch-mode electrostatic actuators [J].
Cabuz, C ;
Cabuz, EI ;
Ohnstein, TR ;
Neus, J ;
Maboudian, R .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 79 (03) :245-250
[6]   ELECTRIC-TO-PNEUMATIC TRANSDUCER AND ITS USE FOR READING BRAILLE [J].
CAEN, R ;
FONADE, C .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1985, 52 (04) :973-974
[7]   CYLINDRICAL PVF2 ELECTRO-MECHANICAL TRANSDUCERS [J].
DAMERON, DH ;
LINVILL, JG .
SENSORS AND ACTUATORS, 1981, 2 (01) :73-84
[8]  
DUDGEON EH, 1971, GAS BEARING S, V5
[9]  
ESHEL A, 1979, J LUBRICATION TECHNO, V1, P86
[10]  
FRIED E, 1989, FLOW RESISTENCE DESI