Focused assessment with sonography for trauma in children after blunt abdominal trauma: A multi-institutional analysis

被引:40
作者
Calder, Bennett W. [1 ]
Vogel, Adam M. [2 ]
Zhang, Jingwen [1 ]
Mauldin, Patrick D. [1 ]
Huang, Eunice Y. [3 ]
Savoie, Kate B. [3 ]
Santore, Matthew T. [4 ]
Tsao, KuoJen [5 ]
Ostovar-Kermani, Tiffany G. [5 ]
Falcone, Richard A.
Dassinger, Sidney [6 ]
Recicar, John [6 ]
Haynes, Jeffrey H. [7 ]
Blakely, Martin L. [8 ]
Russell, Robert T. [9 ]
Naik-Mathuria, Bindi J.
St Peter, Shawn D. [10 ]
Mooney, David P. [11 ]
Onwubiko, Chinwendu [11 ]
Upperman, Jeffrey S. [12 ]
Zagory, Jessica A. [12 ]
Streck, Christian J. [1 ]
机构
[1] Med Univ South Carolina, Dept Surg, Div Pediat Surg, Charleston, SC USA
[2] Washington Univ, St Louis, MO USA
[3] Univ Tennessee, Le Bonheur Childrens Hosp, Memphis, TN USA
[4] Emory Univ, Sch Med, Atlanta, GA USA
[5] Univ Texas Hlth Sci Ctr Houston, Houston, TX 77030 USA
[6] Childrens Hosp, Little Rock, AR USA
[7] Virginia Commonwealth Univ, Richmond, VA USA
[8] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[9] Childrens Hosp Alabama, Birmingham, AL USA
[10] Childrens Mercy Hosp, Kansas City, MO 64108 USA
[11] Boston Childrens Hosp, Boston, MA USA
[12] Childrens Hosp Los Angeles, Los Angeles, CA 90027 USA
关键词
Blunt abdominal trauma; pediatric; focused assessment with sonography for trauma; FAST; COMPUTED-TOMOGRAPHY; ULTRASONOGRAPHY; EMERGENCY; ULTRASOUND; EXPERIENCE; INJURIES; ADULTS; FLUID;
D O I
10.1097/TA.0000000000001546
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
INTRODUCTION: The utility of focused assessment with sonography for trauma (FAST) in children is poorly defined with considerable practice variation. Our purpose was to investigate the role of FAST for intra-abdominal injury (IAI) and IAI requiring acute intervention (IAI-I) in children after blunt abdominal trauma (BAT). METHODS: We prospectively enrolled children younger than 16 years after BAT at 14 Level I pediatric trauma centers over a 1-year period. Patients who underwent FAST were compared with those that did not, using descriptive statistics and univariate analysis; p value less than 0.05 was considered significant. FAST test characteristics were performed using computed tomography (CT) and/or intraoperative findings as the gold standard. RESULTS: Two thousand one hundred eighty-eight children (age, 7.8 +/- 4.6 years) were included. Eight hundred twenty-nine (37.9%) received a FAST, 340 of whom underwent an abdominal CT. Ninety-seven (29%) of these 340 patients had an IAI and 27 (7.9%) received an acute intervention. CT scan utilization after FAST was 41% versus 46% among those who did not receive FAST. The frequency of FAST among centers ranged from 0.84% to 94.1%. There was low correlation between FAST and CT utilization (r = -0.050, p < 0.001). Centers that performed FAST at a higher frequency did not have improved accuracy. The test performance of FAST for IAI was sensitivity, 27.8%; specificity, 91.4%; positive predictive value, 56.2%; negative predictive value, 76.0%; and accuracy, 73.2%. There were 81 injuries among the 70 false-negative FAST. The test performance of FAST for IAI-I was sensitivity, 44.4%; specificity, 88.5%; positive predictive value, 25.0%; negative predictive value, 94.9%; and accuracy, 85.0%. Fifteen children with a negative FAST received acute interventions. Among the 27 patients with true positive FAST examinations, 12 received intervention. All had an abnormal abdominal physical examination. No patient underwent intervention before CT scan. CONCLUSION: As currently used, FAST has a low sensitivity for IAI, misses IAI-I and rarely impacts management in pediatric BAT. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 35 条
[1]   Sonography in a clinical algorithm for early evaluation of 1671 patients with blunt abdominal trauma [J].
Bode, PJ ;
Edwards, MJR ;
Kruit, MC ;
van Vugt, AB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :905-911
[2]  
Boulanger BR, 2000, AM SURGEON, V66, P1049
[3]   Ultrasound based key clinical pathway reduces the use of hospital resources for the evaluation of blunt abdominal trauma [J].
Branney, SW ;
Moore, EE ;
Cantrill, SV ;
Burch, JM ;
Terry, SJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (06) :1086-1090
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Whole-body computed tomographic scanning leads to better survival as opposed to selective scanning in trauma patients: A systematic review and meta-analysis [J].
Caputo, Nicholas D. ;
Stahmer, Chris ;
Lim, George ;
Shah, Kaushal .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 77 (04) :534-539
[6]   Focused abdominal sonography for trauma (FAST) in children with blunt abdominal trauma [J].
Coley, BD ;
Mutabagani, KH ;
Martin, LC ;
Zumberge, N ;
Cooney, DR ;
Caniano, DA ;
Besner, GE ;
Groner, JI ;
Shiels, WE .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (05) :902-906
[7]   Absent peritoneal fluid on screening trauma ultrasonography in children: A prospective comparison with computed tomography [J].
Emery, KH ;
McAneney, CM ;
Racadio, JM ;
Johnson, ND ;
Evora, DK ;
Garcia, VF .
JOURNAL OF PEDIATRIC SURGERY, 2001, 36 (04) :565-569
[8]   Diagnostic and therapeutic laparoscopy in pediatric abdominal trauma [J].
Feliz, A ;
Shultz, B ;
McKenna, C ;
Gaines, BA .
JOURNAL OF PEDIATRIC SURGERY, 2006, 41 (01) :72-77
[9]   CT scan and the pediatric trauma patient - Are we overdoing it? [J].
Fenton, SJ ;
Hansen, KW ;
Meyers, RL ;
Vargo, DJ ;
White, KS ;
Firth, SD ;
Scaife, ER .
JOURNAL OF PEDIATRIC SURGERY, 2004, 39 (12) :1877-1881
[10]   Test Characteristics of Focused Assessment of Sonography for Trauma for Clinically Significant Abdominal Free Fluid in Pediatric Blunt Abdominal Trauma [J].
Fox, J. Christian ;
Boysen, Megan ;
Gharahbaghian, Laleh ;
Cusick, Seric ;
Ahmed, Suleman S. ;
Anderson, Craig L. ;
Lekawa, Michael ;
Langdorf, Mark I. .
ACADEMIC EMERGENCY MEDICINE, 2011, 18 (05) :476-481