Analysis of Operational Strategies of a SOFC/Micro Gas Turbine Hybrid Power Plant

被引:7
作者
Hohloch, Martina [1 ]
Huber, Andreas [1 ]
Aigner, Manfred [1 ]
机构
[1] German Aerosp Ctr DLR, Inst Combust Technol, Pfaffenwaldring 38-40, D-70569 Stuttgart, Germany
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2018年 / 140卷 / 08期
关键词
hybrid power plant rest rig; MGT; SOFC emulator; SYSTEM; PERFORMANCE; SIMULATION;
D O I
10.1115/1.4038605
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present work deals with the analysis of operational concepts for a solid oxide fuel cell/micro gas turbine (SOFC/MGT) hybrid power plant based on a test rig at the DLR, Institute of Combustion Technology. Here, a Turbec T100 MGT and a fuel cell emulator are used. The emulator is composed of two pressure vessels. The first represents the cathode volume of the fuel cell to simulate the residence time and pressure loss. The second is equipped with a natural gas combustor to emulate the varying heat input of the fuel cell. The MGT and the SOFC are connected via different piping paths. The procedures start-up, load change, and shutdown are analyzed in matters of temperature gradients, pressure gradients, and fluctuations, as well as the air mass, flow provided at the interconnections to the coupling elements. To achieve the required inlet conditions of the SOFC, transient operations, using the different piping paths, are investigated. Concepts for heating up and cooling the SOFC using hot air from the recuperator and relatively cold air from the compressor outlet are experimentally tested and characterized. Selected critical situations and their effect on the SOFC are investigated. An emergency operation and its impact on both subsystems and limitations are shown. Further operational limits of the MGT control system and power electronic were observed and analyzed. Based on the experimental results, the applicability of the used MGT procedures in a hybrid power plant was reconsidered. Finally, adaptions and strategies for the operational concept are derived and discussed.
引用
收藏
页数:9
相关论文
共 13 条
[1]  
[Anonymous], GT200850443 ASME
[2]  
[Anonymous], GT201425918 ASME
[3]  
[Anonymous], 20074833 AIAA
[4]  
[Anonymous], GT200727075 ASME
[5]  
[Anonymous], GT201657747 ASME
[6]  
Hohloch M, 2010, GI201022799 ASME
[7]  
Panne T, 2008, GT200850288 ASME
[8]  
Pierre J. F., 2008, DEFC2697FT34139 DOE
[9]   Dynamic simulation of a pressurized 220 kW solid oxide fuel-cell-gas-turbine hybrid system: Modeled performance compared to measured results [J].
Roberts, R. A. ;
Brouwer, J. .
JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2006, 3 (01) :18-25
[10]  
Veyo S. E., 2003, 3 DOE UN INT C WORKS