Performance evaluation of distance relay in the presence of hybrid SFCL

被引:10
作者
Barzegar-Bafrooei, Mohammad Reza [1 ]
Foroud, Asghar Akbari [1 ]
机构
[1] Semnan Univ, Elect & Comp Engn Fac, Semnan, Iran
关键词
superconducting fault current limiters; relay protection; power system security; performance evaluation; hybrid superconducting fault current limiter; distance relay performance; mechanical switch; HSFCL structure; quadrilateral characteristics; security; impedance calculation procedure; FAULT CURRENT LIMITER; 154 KV SFCL;
D O I
10.1049/iet-smt.2017.0366
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents a detailed analysis about the impact of hybrid superconducting fault current limiter (HSFCL) on distance relay performance through the analytical and simulation techniques. For assessments, two possible installation locations for HSFCL (before or after potential transformer (PT)) are considered here which has not been evaluated in the literature so far. Moreover, the impact of action time of fast mechanical switch implemented in the HSFCL structure on impedance trajectory and trip time is investigated. The obtained results show the adverse impact of HSFCL on distance relay performance in all cases. Specially, for forward faults, the worst case happens when HSFCL is installed at the downstream of PT. Using quadrilateral characteristic instead of mho can improve the performance of distance relay; however, this way does not fulfil the enough security and sensitivity under different conditions. Therefore, two approaches are proposed to overcome these challenging situations: (i) modifying trip region of distance relay with respect to the HSFCL impedance and (ii) the new impedance calculation procedure. The significant aspect of the proposed solutions compared with the existing techniques is that the accuracy of distance relay is improved without using additional hardware to provide information from HSFCL.
引用
收藏
页码:581 / 593
页数:13
相关论文
共 30 条
[1]   Survey of Solid-State Fault Current Limiters [J].
Abramovitz, Alexander ;
Smedley, Keuye Ma .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (06) :2770-2782
[2]   Status of Superconducting Fault Current Limiter in Italy: Final Results From the In-Field Testing Activity and Design of the 9 kV/15.6 MVA Device [J].
Angeli, G. ;
Bocchi, M. ;
Ascade, M. ;
Rossi, V. ;
Valzasina, A. ;
Ravetta, C. ;
Martini, L. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
[3]  
[Anonymous], POWERTECH 2009 IEEE
[4]  
[Anonymous], 2012, TECHN WATCH 102490 S, P47
[5]   Investigating the Option of Removing the Antialiasing Filter From Digital Relays [J].
Brahma, Sukumar M. ;
De Leon, Phillip L. ;
Kavasseri, Rajesh G. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) :1864-1868
[6]   A new phasor estimation method for digital protective relays [J].
Campos, Alana K. X. S. ;
Neves, Washington L. A. ;
Fernandes, Damasio, Jr. .
ELECTRIC POWER SYSTEMS RESEARCH, 2017, 142 :227-236
[7]   Overcurrent relays coordination considering transient behaviour of fault current limiter and distributed generation in distribution power network [J].
Chabanloo, R. M. ;
Abyaneh, H. A. ;
Agheli, A. ;
Rastegar, H. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2011, 5 (09) :903-911
[8]   Effects of a voltage compensation type active superconducting fault current limiter on distance relay protection [J].
Chen, L. ;
Tang, Y. J. ;
Shi, J. ;
Ren, L. ;
Song, M. ;
Cheng, S. J. ;
Hu, Y. ;
Chen, X. S. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2010, 470 (20) :1662-1665
[9]   Performance analysis of a Superconducting Fault Current Limiter in a power distribution substation [J].
Colmenar-Santos, Antonio ;
Pecharroman-Lazaro, J. M. ;
de Palacio Rodriguez, Carlos ;
Collado-Fernandez, Eduardo .
ELECTRIC POWER SYSTEMS RESEARCH, 2016, 136 :89-99
[10]   Bridge-type superconducting fault current limiter effect on distance relay characteristics [J].
Firouzi, M. ;
Gharehpetian, G. B. ;
Mozafari, B. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 68 :115-122