A quantitative Monte Carlo modelling of the uranium and plutonium X-ray fluorescence (XRF) response from a hybrid K-edge/K-XRF densitometer

被引:11
作者
Berlizoy, A. N. [1 ,2 ]
Sharikov, D. A. [2 ,3 ]
Ottmar, H. [2 ]
Eberle, H. [2 ]
Galy, J. [2 ]
Luetzenkirchen, K. [2 ]
机构
[1] Natl Acad Sci Ukraine, Inst Nucl Res, UA-03680 Kiev, Ukraine
[2] European Commiss, Inst Transuranium Elements, Joint Res Ctr, D-76125 Karlsruhe, Germany
[3] Tomsk Polytech Univ, Tomsk 634050, Russia
关键词
Uranium; Plutonium; Solution; Hybrid densitometry; Modelling; Monte Carlo;
D O I
10.1016/j.nima.2010.01.010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A mathematical simulation approach based on the general purpose Monte Carlo N-particle transport code MCNP was developed to predict the response of the XRF branch of the hybrid K-edge/K-XRF densitometer (HKED). The respective MCNP models for two different versions of HKED instruments currently in use were set up and experimentally validated. The setting up of the models involved comprehensive simulations of a bremsstrahlung photon source, the examination of different particle transport models, as well as the examination of different photon attenuation and X-ray fluorescence data libraries. The computation speed was significantly increased through the extensive use of the variance reduction techniques. The models were validated through the series of benchmarking experiments performed with a representative set of uranium, plutonium and mixed U/Pu reference solutions. The models and simulation approach developed are intended for: (i) establishing a consistent mathematical calibration approach for the XRF branch of the HKED instruments, which will require minimum calibration effort and time, (ii) extending the applicability of the HKED method to nonstandard samples (e.g. U/Pu mixtures with unusual element ratios) and non-standard sample matrices (e.g. HM matrices from the pyro-processing of irradiated nuclear fuel) without investing a great deal of extra calibration work, and (iii) improving the accuracy of the measurements through the modelling of special measurement effects (e.g. the secondary excitation effect, the interference with X-ray escape peaks, the inconsistent unfolding of the overlapping peaks and peak background delineation in the measured XRF spectrum), which are difficult or sometimes impossible to account for experimentally. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 13 条
  • [1] [Anonymous], 1997, P 19 ANN ESARDA S MO
  • [2] Berlizov A.N., 2006, ACS Symp. Series., V945, P183, DOI [DOI 10.1021/BK-2007-0945.CH013, 10.1021/bk-2007-0945.ch013]
  • [3] Booth T.E., 1985, LA-10363-MS
  • [4] Briesmeister J.F., 2000, MCNP-A general Monte Carlo N -particle transport code, version 4A, V2
  • [5] *CAN IND INC, 2000, SOFTW US MAN CANB K
  • [6] COLLINS ML, 2002, HKEDUM00300X LOS AL
  • [7] DANILENKO VN, 2007, T 10 INT M PROBL APP, V15
  • [8] EVERETT CJ, 1973, LA5240MS LOS AL SCI
  • [9] OTTMAR H, 1999, P 40 ANN INMM M PHOE
  • [10] OTTMAR H, 1983, ESARDA B, P19