Lactate compared with pH analysis at fetal scalp blood sampling: a prospective randomised study

被引:93
作者
Westgren, M [1 ]
Kruger, K
Ek, S
Grunevald, C
Kublickas, M
Naka, K
Wolff, K
Persson, B
机构
[1] Huddinge Univ Hosp, Karolinska Inst, Dept Obstet & Gynaecol, S-14186 Huddinge, Sweden
[2] Karolinska Inst, St Gorans Childrens Hosp, Dept Paediat, S-11281 Stockholm, Sweden
[3] Osaka City Univ, Sch Med, Dept Lab Med, Osaka, Japan
来源
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY | 1998年 / 105卷 / 01期
关键词
D O I
10.1111/j.1471-0528.1998.tb09346.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective Fetal scalp blood sampling is a widely used method for assessing fetal condition in the event of ominous fetal heart rate patterns. The purpose of this randomised trial was to compare the value of fetal scalp blood lactate and pH management in cases of abnormal intrapartum fetal heart rate tracings. Methods Of 341 cases of ominous fetal heart rate patterns, 169 were randomly assigned to pH analysis, and 172 to lactate measurements. Lactate was measured using a lactate card requiring 5 mu L of blood and yielding the result within 60 seconds. pH analysis was performed with an ABL 510 acid-base analyser requiring 35 mu L of blood and yielding the results within 47 seconds. Results Unsuccessful fetal blood sampling procedures (no result or an unreliable result) occurred significantly more often in the pH subgroup than in the lactate subgroup (OR 16.1 with 95% CI 5.8-44.7). In the pH subgroup the failure rate was inversely related to the degree of cervical dilatation. Compared with the pH subgroup, the lactate subgroup was characterised by fewer fetal scalp incisions per blood sampling attempt (median 1.0 [interquartile range (IQR) 1-1] vs 2.0 [IQR 1-2]), and significantly less time required for the sampling procedure (median 120 s [IQR 90-147] vs 230 s [IQR 180-300]). The groups did not differ in mode of delivery, neonatal outcome and umbilical artery acid-base balance and lactate levels. Conclusion This trial showed the levels of lactate and pH in fetal scalp blood to be comparable in predicting perinatal outcome, but the procedure to measuring lactate was more successful than that for pH. Owing to its simplicity of performance, lactate analysis is an attractive alternative for intrapartum fetal monitoring.
引用
收藏
页码:29 / 33
页数:5
相关论文
共 17 条
[1]  
GOODWIN TM, 1994, OBSTET GYNECOL, V83, P971
[2]   CONTROLLED TRIAL OF THE DIFFERENTIAL EFFECTS OF INTRAPARTUM FETAL MONITORING [J].
HAVERKAMP, AD ;
ORLEANS, M ;
LANGENDOERFER, S ;
MCFEE, J ;
MURPHY, J ;
THOMPSON, HE .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1979, 134 (04) :399-412
[3]   SCALP BLOOD LACTATE - A NEW TEST STRIP METHOD FOR MONITORING FETAL WELL-BEING IN LABOR [J].
NORDSTROM, L ;
INGEMARSSON, I ;
KUBLICKAS, M ;
PERSSON, B ;
SHIMOJO, N ;
WESTGREN, M .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (11) :894-899
[4]   FETAL SCALP AND UMBILICAL ARTERY BLOOD LACTATE MEASURED WITH A NEW TEST STRIP METHOD [J].
NORDSTROM, L ;
PERSSON, B ;
SHIMOJO, N ;
WESTGREN, M .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (04) :307-309
[5]  
NORDSTROM L, 1994, ACTA OBSTET GYNECOL, V73, P50
[7]  
RAIHA NCR, 1963, PEDIATRICS, V32, P1025
[8]  
ROOTH G, 1964, CLIN SCI, V26, P121
[9]   PERINATAL BRAIN-DAMAGE - PREDICTIVE VALUE OF METABOLIC-ACIDOSIS AND THE APGAR SCORE [J].
RUTH, VJ ;
RAIVIO, KO .
BRITISH MEDICAL JOURNAL, 1988, 297 (6640) :24-27
[10]  
SHIMOJO N, 1993, CLIN CHEM, V39, P2312