Improved blood cellular biocompatibility with heparin coated circuits during cardiopulmonary bypass

被引:0
|
作者
Belboul, A [1 ]
Akbar, O [1 ]
Löfgren, C [1 ]
Jungbeck, M [1 ]
Storm, C [1 ]
Roberts, A [1 ]
机构
[1] Gothenburg Univ, Sahlgrens Univ Hosp, Dept Thorac & Cardiovasc Surg, S-41345 Gothenburg, Sweden
关键词
extracorporeal circulation instrumentation; heparin; cardiopulmonary bypass; cardiac surgical procedures; biocompatible materials;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical use of heparinized surfaces in the extracorporeal circuit was studied to find out if there was any blood cell theologic benefit to support its use in routine low risk cardiac surgery. Methods. In a prospective single blind study, 39 patients were operated upon with the heart lung machine for angina pectoris by coronary bypass grafting and were randomized to a control group or a heparin group. Blood cell rheology was analysed using the St. George filtrometer where damage to the red blood cells and white blood cells was estimated by assessing deformability reductions, transit, time increases and clogging rate and clogging particle changes. Results. At the end of cardiopulmonary bypass, in the heparin group, the red cell filterability (rFR) and the white cell filterability (WFR) were 8% better than in the control group (p = 0.0079 and p = 0.027 respectively). The red cell transit time was 19% slower in the control group (p = 0.0351), The red cell clogging rate (RCR) and clogging particles (RCP) were significantly lower in the heparin group (p = 0.0212 and p = 0.0409 respectively. The white cell clogging rate (WCR) and clogging particles (WCP) showed a similar pattern. Conclusions. In spite of these significant differences the clinical outcome was similar in the groups. Thus heparin coating of the extracorporeal circuit reduces blood cell theologic damage significantly in low risk patients undergoing routine bypass surgery for angina but this use did not lead to any clinical benefit postoperatively. Therefore the use of such circuits for routine low risk cardiac surgery cannot be recommended.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 50 条
  • [21] Comparable biocompatibility of Phisio- and Bioline-coated cardiopulmonary bypass circuits indicated by the inflammatory response
    Thiara, A. S.
    Andersen, V. Y.
    Videm, V.
    Mollnes, T. E.
    Svennevig, K.
    Hoel, T. N.
    Fiane, A. E.
    PERFUSION-UK, 2010, 25 (01): : 9 - 16
  • [22] Measurement of activated clotting time and whole blood heparin concentration during cardiopulmonary bypass
    Takashi Watanabe
    Kazuaki Shirota
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (6): : 530 - 530
  • [23] Heparin resistance during cardiopulmonary bypass
    Jung, Hyun Ju
    Kim, Jong Bun
    Im, Kyong Shil
    Oh, Seung Hwa
    Lee, Jae Myeong
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2009, 10 (12) : 940 - 941
  • [24] Descending thoracic aortic aneurysm repair with the aid of partial cardiopulmonary bypass: Heparin-coated circuits versus nonheparin-coated circuits
    Morishita, K
    Kawaharada, N
    Fukada, J
    Hachiro, Y
    Kurimoto, Y
    Fujisawa, Y
    Saito, T
    Abe, T
    ARTIFICIAL ORGANS, 2005, 29 (04) : 300 - 305
  • [25] Heparin-bonded cardiopulmonary bypass circuits reduce the rate of red blood cell transfusion during elective coronary artery bypass surgery
    Kreisler, KR
    Vance, RA
    Cruzzavala, J
    Mahnken, JD
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (05) : 608 - 611
  • [26] Heparin-coated cardiopulmonary bypass circuits reduce circulating complement factors and interleukin-6 in paediatric heart surgery
    Olsson, C
    Siegbahn, A
    Henze, A
    Nilsson, B
    Venge, P
    Joachimsson, PO
    Thelin, S
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2000, 34 (01) : 33 - 40
  • [27] Use of heparin-bonded circuits in cardiopulmonary bypass improves clinical outcome
    Svenmarker, S
    Häggmark, S
    Jansson, E
    Lindholm, R
    Appelblad, M
    Sandström, E
    Åberg, T
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2002, 36 (04) : 241 - 246
  • [28] Real time measurement of heparin concentration during cardiopulmonary bypass
    Hashimoto, K
    Sasaki, T
    Hachiya, T
    Takakura, H
    Onoguchi, K
    Nagahori, R
    Takeuchi, S
    JOURNAL OF CARDIOVASCULAR SURGERY, 1999, 40 (05) : 645 - 651
  • [29] Biocompatibility and pathways of initial complement pathway activation with Phisio- and PMEA-coated cardiopulmonary bypass circuits during open-heart surgery
    Thiara, A. S.
    Mollnes, T. E.
    Videm, V.
    Andersen, V. Y.
    Svennevig, K.
    Kolset, S. O.
    Fiane, A. E.
    PERFUSION-UK, 2011, 26 (02): : 107 - 114
  • [30] Effects of heparin coating of cardiopulmonary bypass circuits on in vitro oxygen free radical production during coronary bypass surgery
    Bozdayi, M
    Borowiec, J
    Nilsson, L
    Venge, P
    Thelin, S
    Hansson, HE
    ARTIFICIAL ORGANS, 1996, 20 (09) : 1008 - 1016