Improved blood cellular biocompatibility with heparin coated circuits during cardiopulmonary bypass

被引:0
|
作者
Belboul, A [1 ]
Akbar, O [1 ]
Löfgren, C [1 ]
Jungbeck, M [1 ]
Storm, C [1 ]
Roberts, A [1 ]
机构
[1] Gothenburg Univ, Sahlgrens Univ Hosp, Dept Thorac & Cardiovasc Surg, S-41345 Gothenburg, Sweden
关键词
extracorporeal circulation instrumentation; heparin; cardiopulmonary bypass; cardiac surgical procedures; biocompatible materials;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical use of heparinized surfaces in the extracorporeal circuit was studied to find out if there was any blood cell theologic benefit to support its use in routine low risk cardiac surgery. Methods. In a prospective single blind study, 39 patients were operated upon with the heart lung machine for angina pectoris by coronary bypass grafting and were randomized to a control group or a heparin group. Blood cell rheology was analysed using the St. George filtrometer where damage to the red blood cells and white blood cells was estimated by assessing deformability reductions, transit, time increases and clogging rate and clogging particle changes. Results. At the end of cardiopulmonary bypass, in the heparin group, the red cell filterability (rFR) and the white cell filterability (WFR) were 8% better than in the control group (p = 0.0079 and p = 0.027 respectively). The red cell transit time was 19% slower in the control group (p = 0.0351), The red cell clogging rate (RCR) and clogging particles (RCP) were significantly lower in the heparin group (p = 0.0212 and p = 0.0409 respectively. The white cell clogging rate (WCR) and clogging particles (WCP) showed a similar pattern. Conclusions. In spite of these significant differences the clinical outcome was similar in the groups. Thus heparin coating of the extracorporeal circuit reduces blood cell theologic damage significantly in low risk patients undergoing routine bypass surgery for angina but this use did not lead to any clinical benefit postoperatively. Therefore the use of such circuits for routine low risk cardiac surgery cannot be recommended.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 50 条
  • [1] BIOCOMPATIBILITY OF HEPARIN-COATED CIRCUITS USED IN CARDIOPULMONARY BYPASS
    PEKNA, M
    BOROWIEC, J
    FAGERHOL, MK
    VENGE, P
    THELIN, S
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 28 (01): : 5 - 11
  • [2] Biocompatibility reflected by haemostasis variables during cardiopulmonary bypass using heparin-coated circuits
    Borowiec, J
    Bagge, L
    Saldeen, T
    Thelin, S
    THORACIC AND CARDIOVASCULAR SURGEON, 1997, 45 (04) : 163 - 167
  • [3] BIOCOMPATIBILITY OF HEPARIN-COATED MEMBRANE-OXYGENATOR DURING CARDIOPULMONARY BYPASS
    HATORI, N
    YOSHIZU, H
    HAGA, Y
    KUSAMA, Y
    TAKESHIMA, S
    SEGAWA, D
    TANAKA, S
    ARTIFICIAL ORGANS, 1994, 18 (12) : 904 - 910
  • [4] Protective Effect of Heparin-coated Circuits on the Platelets during Cardiopulmonary Bypass
    张凯伦
    胡志伟
    杨运海
    黄如清
    范慧敏
    孙宗全
    华中科技大学学报(医学英德文版), 2003, (04) : 403 - 406
  • [5] Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass
    Zhang Kailun
    Hu Zhiwei
    Yang Yunhai
    Huang Ruqing
    Fan Huiming
    Sun Zongquan
    Current Medical Science, 2003, 23 (4) : 403 - 406
  • [6] The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass
    de Vroege, R
    Huybregts, R
    van Oeveren, W
    van Klarenbosch, J
    Linley, G
    Mutlu, J
    Jansen, E
    Hack, E
    Eijsman, L
    Wildevuur, C
    ARTIFICIAL ORGANS, 2005, 29 (06) : 490 - 497
  • [7] Haemostasis at low heparin dosage during cardiopulmonary bypass with heparin-coated circuits in pigs
    Bagge, L
    Borowiec, JW
    Thelin, S
    Hultman, J
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 1997, 31 (05) : 275 - 281
  • [8] Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass
    Saito, N
    Motoyama, S
    Sawamoto, J
    ARTIFICIAL ORGANS, 2000, 24 (07) : 547 - 554
  • [9] A prospective randomized trial comparing the clinical effectiveness and biocompatibility of heparin-coated circuits and PMEA-coated circuits in pediatric cardiopulmonary bypass
    Itoh, Hideshi
    Ichiba, Shingo
    Ujike, Yoshihito
    Douguchi, Takuma
    Kasahara, Shingo
    Arai, Sadahiko
    Sano, Shunji
    PERFUSION-UK, 2016, 31 (03): : 247 - 254
  • [10] Heparin-coated circuits reduce the formation of TNF alpha during cardiopulmonary bypass
    Yamada, H
    Kudoh, I
    Hirose, Y
    Toyoshima, M
    Abe, H
    Kurahashi, K
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (03) : 311 - 317